Opportunity
Georgetown Ionwave #202709 Addendum 3
CMAR services for Georgetown Fire Station No. 8
Posted
November 05, 2026
Respond By
December 01, 2026
Identifier
202709 Addendum 3
NAICS
236220, 238910
The City of Georgetown, Texas, is seeking a Construction Manager at Risk for its new Fire Station No. 8. - Buyer and project - Buyer: City of Georgetown, Public Works Department; solicitation managed by the Purchasing Department. Nicole Abrego is identified as the buyer, and Eric Johnson as the Owner’s representative. - Project: Fire Station No. 8, CMAR No. 202709, at 1901 Westinghouse Road in Georgetown. - Requested services - Preconstruction: project coordination, estimating, scheduling, constructability reviews, value engineering, procurement planning, and preparation of a Guaranteed Maximum Price (GMP) proposal. - Construction phase: subcontractor bidding, construction administration, supervision, and delivery of the work under the contract documents. - Proposals include separate lump-sum prices for preconstruction and general conditions, plus a CMAR fee percentage. - Facility scope and budget - Approximately 12,000–13,025 gross square feet, including staff living, working, and sleeping areas; three pull-through apparatus bays; utilities; site improvements; and related work. - Estimated construction budget: $8.7 million. Fire Station No. 7 is a reference point, not a prototype; the new station is not expected to be a pre-engineered metal building. - Named firms - GFF, Inc. is identified by the latest clarification as the project architect; this supersedes earlier references to Brown Reynolds and Watford. Parkhill is also named as architect in an earlier project document, creating a conflicting reference. - Kimley-Horn is mentioned in connection with civil engineering. - Notable requirements and planning assumptions - Preconstruction is anticipated to last about nine months; construction is estimated at 365 calendar days, subject to adjustment. - Price time-dependent general conditions using a 180-day construction assumption for evaluation; actual duration and costs are to be finalized through the GMP process. - No geotechnical report or lot survey was available in the project information reviewed. - The agreement excerpt provides for $650 per calendar day in liquidated damages for late Substantial Completion and 5% retainage. Payment and performance bonds are not required with the proposal; security bonding is required from the successful contractor after contract execution.
Description
The City of Georgetown seeks proposals from qualified respondents to provide Construction Manager at Risk (CMAR) services for construction of a new Georgetown Fire Station No. 8 at 1901 Westinghouse Rd, Georgetown, Texas. The solicitation follows a one-step selection process under Texas Government Code Chapter 2269, Subchapter F, Section 2269.253. Proposals must be submitted electronically through the City E-bid system by December 1, 2026, at 2:30 PM CT. Addendum No. 3 clarifies that GFF, Inc. is the project architect.