Opportunity

SAM #36C25027Q0125

Cincinnati VA Emergency Generator and Paralleling-Switchgear Repairs

Buyer

VA Network Contracting Office 10

Posted

November 24, 2026

Respond By

December 07, 2026

Identifier

36C25027Q0125

NAICS

811310

The Department of Veterans Affairs is seeking capable firms to repair and restore emergency generator and paralleling-switchgear operations at Cincinnati VA Medical Center; the attachments also document related equipment and electrical work. - Government buyer: Department of Veterans Affairs, Network Contracting Office 10; work is at Cincinnati VA Medical Center / VA Hospital Cincinnati. An attached construction document also identifies the VA Office of Construction and Facilities Management. - OEMs and named vendors: ABB (switchgear service and repair; ABB paralleling-switchgear documentation), GE / GE Zenith Controls (switchgear, breakers, and controls), Kohler (generators), MTU Detroit Diesel (generator engines), and VICOR (module referenced in prior repair work). No other repair contractor is identified by name. - Requested work: Restore generator and paralleling-switchgear operation; repair two Kohler emergency generators, replace and program protective relays, modify switchgear door and wiring, update ABB drawings, and perform generator, load-bank, paralleling, and system commissioning tests. - Generator details: Two Kohler model 1500REOZDC units, each identified as 1,560 kW, 277/480 V, with MTU Detroit Diesel T1238A36 engines. Drawings separately depict two Kohler 1,500 kW generators. - Documented switchgear and controls: GE Zenith Controls 5,000 A, 480/277 V switchgear with GE EntelliGuard G breakers; 65 kAIC short-circuit capacity, 100 kA bus bracing, 100% neutral, and Modbus communications. Drawings also show GE VersaMax PLCs and annunciator panels serving 25 ATS units. - Additional documented equipment and work: GE breaker and switchgear inspection/testing; PLC and I/O-card work; MFR13 and reverse-power relay upgrades; generator control and system testing. Another attached electrical-deficiency document lists unit substations, ATSs, panelboard retrofits, neutral separations, and temporary-power provisions; its scope and quantities are included in the line items below. - Notable requirements: Licensed Professional Engineer oversight, government coordination for generator work on separate weekends, load-bank testing of more than four hours, updated drawings and programming files, and full operational testing. Standby power may be unavailable during some switchgear procedures, requiring a temporary generator to support critical and life-safety loads. - Opportunity status: Sources-sought notice for acquisition planning, not a request for proposals. No quantities are specified for the core repair services.

Description

The Cincinnati Veterans Administration Medical Center (VAMC) has a requirement to provide repairs to generator operation to address failed generators & associated paralleling switchgear.
The intention of this Sources Sought is to obtain information only. Please do not send a proposal or questions. Requested information: To aid acquisition planning, we re seeking capable and interested firms for the information requested. If your firm meets the criteria please send the point of contact (ronald.heidemann@va.gov) the following, via email: Firm s Name
Socio-Economic Status Whether or not your company has a contract vehicle we can order against If your company believes there is an alternative NAICS code please provide this

Please attachments for more information.