Cincinnati VA Emergency Generator and Paralleling-Switchgear Repairs

**Buyer:** VA Network Contracting Office 10
**Posted:** November 24, 2026
**Respond By:** December 07, 2026
**Identifier:** 36C25027Q0125
**NAICS:** 811310

The Department of Veterans Affairs is seeking capable firms to repair and restore emergency generator and paralleling-switchgear operations at Cincinnati VA Medical Center; the attachments also document related equipment and electrical work.
- **Government buyer:** Department of Veterans Affairs, Network Contracting Office 10; work is at Cincinnati VA Medical Center / VA Hospital Cincinnati. An attached construction document also identifies the VA Office of Construction and Facilities Management.
- **OEMs and named vendors:** **ABB** (switchgear service and repair; ABB paralleling-switchgear documentation), **GE / GE Zenith Controls** (switchgear, breakers, and controls), **Kohler** (generators), **MTU Detroit Diesel** (generator engines), and **VICOR** (module referenced in prior repair work). No other repair contractor is identified by name.
- **Requested work:** Restore generator and paralleling-switchgear operation; repair two Kohler emergency generators, replace and program protective relays, modify switchgear door and wiring, update ABB drawings, and perform generator, load-bank, paralleling, and system commissioning tests.
- **Generator details:** Two Kohler model 1500REOZDC units, each identified as 1,560 kW, 277/480 V, with MTU Detroit Diesel T1238A36 engines. Drawings separately depict two Kohler 1,500 kW generators.
- **Documented switchgear and controls:** GE Zenith Controls 5,000 A, 480/277 V switchgear with GE EntelliGuard G breakers; 65 kAIC short-circuit capacity, 100 kA bus bracing, 100% neutral, and Modbus communications. Drawings also show GE VersaMax PLCs and annunciator panels serving 25 ATS units.
- **Additional documented equipment and work:** GE breaker and switchgear inspection/testing; PLC and I/O-card work; MFR13 and reverse-power relay upgrades; generator control and system testing. Another attached electrical-deficiency document lists unit substations, ATSs, panelboard retrofits, neutral separations, and temporary-power provisions; its scope and quantities are included in the line items below.
- **Notable requirements:** Licensed Professional Engineer oversight, government coordination for generator work on separate weekends, load-bank testing of more than four hours, updated drawings and programming files, and full operational testing. Standby power may be unavailable during some switchgear procedures, requiring a temporary generator to support critical and life-safety loads.
- **Opportunity status:** Sources-sought notice for acquisition planning, not a request for proposals. No quantities are specified for the core repair services.

### Description

The Cincinnati Veterans Administration Medical Center (VAMC) has a requirement to provide repairs to generator operation to address failed generators & associated paralleling switchgear.  
The intention of this Sources Sought is to obtain information only.  Please do not send a proposal or questions.
Requested information: 
To aid acquisition planning, we re seeking capable and interested firms for the information requested. If your firm meets the criteria please send the point of contact (ronald.heidemann@va.gov) the following, via email: 
Firm s Name  
Socio-Economic Status 
Whether or not your company has a contract vehicle we can order against
If your company believes there is an alternative NAICS code please provide this

Please attachments for more information.