Opportunity
Plano Independent School District Ionwave #CSP 2027-01-02 Addendum 2
Brinker Elementary School HVAC Controls, Chiller, RTU, and Related Systems Upgrades
Posted
October 30, 2026
Respond By
December 01, 2026
Identifier
CSP 2027-01-02 Addendum 2
NAICS
238220, 334512
Plano Independent School District is seeking proposals to upgrade HVAC and related systems at Brinker Elementary School. - Buyer: Plano Independent School District (Plano ISD), Purchasing Department / Plano ISD Purchasing, Plano, Texas. - Base scope: Replace the campus HVAC controls system, existing air-cooled chillers, and three rooftop units (RTUs), with associated mechanical, electrical, and controls work. - Alternates and allowances: Alternate work includes one kitchen make-up air unit (MAU) replacement with demand control ventilation and backflow-preventer replacement. A $50,000 allowance covers valves, actuators, and strainers. Visitor signage is handled through project contingency and is not required in the base bid. - OEMs and named vendors: Reliable Controls is the only acceptable controls manufacturer/vendor and is provided by Enviromatics; the existing controls system is Schneider. Carrier is acceptable for the MAU (model 48WE); CaptiveAire, Greenheck, and Grease Master are also named in the MAU specification discussion. Existing chillers are identified as Carrier 30RBA units. Solenis (formerly Chem-Aqua) provides the district’s chemical water treatment, and EAB will provide testing-and-balancing pricing directly to the district. - Notable requirements: Include chiller factory start-up by the manufacturer’s authorized technician in the base bid. Field-verify existing conditions, equipment counts, sizes, and chiller-pad adequacy; account for equipment-related structural work. Coordinate water treatment with Solenis. EAB’s testing-and-balancing cost is excluded from the contractor’s proposal. Unused allowance funds are returned to the owner. - Budget: Estimated project budget is $1,600,000; source summaries differ on whether the $80,000 contingency and $50,000 allowance are included in that figure.
Description
Plano Independent School District is requesting competitive sealed proposals for the Brinker Elementary School Systems & Compliance Project. The base bid includes replacing campus HVAC controls, existing air-cooled chillers, and three rooftop units, plus associated mechanical, electrical, and controls work. Alternate work includes replacement of the existing make-up air unit and associated work. The stated estimated budget is $1,600,000, with an $80,000 contingency and a $50,000 allowance for replacement of valves, actuators, and strainers.