332322

The Department of the Air Force is seeking a complete roof snow and ice retention system for Building 618 at Little Rock Air Force Base. - Government buyer: Department of the Air Force, Air Mobility Command, 19th Contracting Squadron, Little Rock Air Force Base. - Scope: Provide at least 720 linear feet of continuous snow and ice retention coverage for a vertical standing-seam metal roof. - System requirements: Use non-penetrating stainless-steel seam clamps, aluminum rails, and aluminum ice stoppers; include thermal expansion capability and a project-specific layout and bill of materials. - Notable performance requirement: Document clamp capacity of at least 1,500 pounds. No OEM, vendor, or part number is specified. - Requested components: 120 rail sections, 600 seam clamps, 1,200 set screws, 960 ice stoppers, 750 self-drilling fasteners, 120 expansion splices, and 15 installation bits.

Description

This acquisition is a new requirement for the procurement of an engineered, continuous pipe or fence-style rail snow retention system for facility roof installation. 

System Configuration: Must be a continuous horizontal pipe- or fence-style rail snow retention system capable of bridging across structural roof panels and providing continuous longitudinal perimeter retention.   Retention Capacity & Coverage: System must furnish 720 linear feet of continuous perimeter retention coverage.   Substrate Compatibility: Mounting clamps and hardware must be fully compatible with the host metal roofing profile (e.g., standing seam or exposed fastener). Attachment systems for standing-seam profiles must utilize non-penetrating clamping mechanisms to preserve the weather-tight integrity and manufacturer warranty of the roof panels.   Structural Performance Thresholds:   System components (brackets, clamps, rails, and fasteners) must be engineered and rated to resist site-specific snowpack and ice accumulation shear loads without permanent mechanical deflection.   Clamp-to-seam holding strength must meet or exceed minimum structural thresholds (e.g., capable of sustaining design loads up to 500 lbs per clamp or linear foot minimum, adjusted to site-specific engineering design calculations).   Fastening hardware must utilize round-point or non-cutting setscrew designs (e.g., 300-series stainless steel per ASTM F880) to prevent piercing, galling, or compromising protective coatings on metal roof seams.

View original listing