Opportunity
Quebec SEAO #JD-AI-20260917-2
Procurement of Non-mydriatic Ultra Wide Field Retinal Camera for Santé Québec Laurentides
Posted
September 28, 2026
Respond By
October 09, 2026
Identifier
JD-AI-20260917-2
NAICS
423460, 423490, 339115
Santé Québec Laurentides, a regional health authority in Quebec, is seeking to procure a specialized retinal imaging device for clinical use. - Government Buyer: - Santé Québec Laurentides (regional health authority) - OEMs and Vendors: - Optos Canada (designated as sole provider) - Products/Services Requested: - Non-mydriatic ultra wide field retinal camera - Must capture retinal images with pupils as small as 2.0 mm - Capable of imaging through grades 1-3 cataracts - Single-shot coverage of over 180° of the retina - Generates four specific retinal images - Supports image montage up to 220° - Compatible with EyeVu electronic medical record system (TeckSoft) - French software and user interface - Includes DICOM licenses, image management platform, virtual server support - Adjustable motorized table, no dedicated computer required - Annotation and measurement tools - Prior installation in other Santé Québec establishments - Minimum one-year warranty - Ongoing clinical training and robust after-sales support (4-hour callback, 72-hour on-site technician, loaner camera if repairs exceed 72 hours) - Health Canada certification, compliance with CAN/CSA-C22.2 NO. 60601-1 - Option to acquire a second camera with identical specifications - Unique/Notable Requirements: - French-language software and interface - Compatibility with EyeVu EMR - Demonstrated prior installation in Santé Québec - No pricing information to be submitted - Suppliers must prove ability to meet all technical and clinical requirements - Robust after-sales and clinical training support - Optos Canada is the only OEM explicitly mentioned and identified as the sole provider capable of meeting all requirements.
Description
This procurement is for a non-mydriatic ultra wide field retinal camera, with an option to acquire a second similar camera. The camera must meet specific technical requirements including capturing retinal photos with small pupils, imaging through cataracts, covering a wide retinal angle, and compatibility with electronic medical record systems. The procurement is a direct award to Optos Canada, the only supplier meeting the clinical, IT, and technical requirements. Interested suppliers must demonstrate their capacity to meet the requirements without submitting pricing information.