Opportunity

Quebec SEAO #JD-AI-20260917-2

Procurement of Non-mydriatic Ultra Wide Field Retinal Camera for Santé Québec Laurentides

Posted

September 28, 2026

Respond By

October 09, 2026

Identifier

JD-AI-20260917-2

NAICS

423460, 423490, 339115

Santé Québec Laurentides, a regional health authority in Quebec, is seeking to procure a specialized retinal imaging device for clinical use. - Government Buyer: - Santé Québec Laurentides (regional health authority) - OEMs and Vendors: - Optos Canada (designated as sole provider) - Products/Services Requested: - Non-mydriatic ultra wide field retinal camera - Must capture retinal images with pupils as small as 2.0 mm - Capable of imaging through grades 1-3 cataracts - Single-shot coverage of over 180° of the retina - Generates four specific retinal images - Supports image montage up to 220° - Compatible with EyeVu electronic medical record system (TeckSoft) - French software and user interface - Includes DICOM licenses, image management platform, virtual server support - Adjustable motorized table, no dedicated computer required - Annotation and measurement tools - Prior installation in other Santé Québec establishments - Minimum one-year warranty - Ongoing clinical training and robust after-sales support (4-hour callback, 72-hour on-site technician, loaner camera if repairs exceed 72 hours) - Health Canada certification, compliance with CAN/CSA-C22.2 NO. 60601-1 - Option to acquire a second camera with identical specifications - Unique/Notable Requirements: - French-language software and interface - Compatibility with EyeVu EMR - Demonstrated prior installation in Santé Québec - No pricing information to be submitted - Suppliers must prove ability to meet all technical and clinical requirements - Robust after-sales and clinical training support - Optos Canada is the only OEM explicitly mentioned and identified as the sole provider capable of meeting all requirements.

Description

This procurement is for a non-mydriatic ultra wide field retinal camera, with an option to acquire a second similar camera. The camera must meet specific technical requirements including capturing retinal photos with small pupils, imaging through cataracts, covering a wide retinal angle, and compatibility with electronic medical record systems. The procurement is a direct award to Optos Canada, the only supplier meeting the clinical, IT, and technical requirements. Interested suppliers must demonstrate their capacity to meet the requirements without submitting pricing information.

View original listing