NIH plans a sole-source maintenance agreement for its BD Symphony S6 flow cytometer and five associated lasers. - Buyer: HHS, NIH, NIAID, Division of Intramural Research, Laboratory of Viral Diseases, Section of Barrier Immunity. - Intended provider and OEM: BD Biosciences, Inc.; NIH states it is the only identified source able to provide the required OEM-certified technicians, parts, software revisions, and support. - Equipment covered: One BD Symphony S6 flow cytometer (serial number R66293700030) and five lasers: G4 355-60 w/BD UV; SAPPHIRE 488-400 Blue; MPB 532-1000 SORP Green; MPB 628-1000 .3mm Red SORP; and OBIS 405-100 LX Violet. - Required service: Two preventive maintenance inspections and PM kits per contract year; emergency on-site response within 48 hours; unlimited weekday on-site visits and telephone support; repairs or replacement as needed; parts, labor, travel, and software revisions. Service visit records must identify new parts provided. - Term and value: Anticipated January 5, 2027–January 4, 2030, consisting of a one-year base period and two option years. Estimated total value, including options, is $250,840.80. - Notice status: This is a notice of intent, not a solicitation. Interested sources may submit capability information demonstrating equivalent service authorization, access to parts and software, technician qualifications, and the required response capability.
Description
NOTICE OF INTENT TO AWARD A SOLE SOURCE CONTRACT
Notice Number: NIH-NOI-27-PCA-NIAID-12580 Posted Date: November 25, 2026 Response Due Date: December 7, 2026 Classification Code: 6640 – Laboratory Equipment and Supplies NAICS Code: 811210 – Electronic and Precision Equipment Repair and Maintenance
1. Agency and Contracting Activity
Department of Health and Human Services (HHS) National Institutes of Health (NIH) National Institute of Allergy and Infectious Diseases (NIAID) Division of Intramural Research (DIR) Laboratory of Viral Diseases (LVD)
For: Section of Barrier Immunity Building 33, Room 1E05 33 North Drive Bethesda, MD 20892
Project Number: PCA-NIAID-12580 Project Title: Service Contract for BD Symphony S6 (Base Plus Two Option Years)
2. Action Being Announced
This is a notice of intent, and not a request for competitive quotations, proposals, or bids.
The National Institutes of Health (NIH), on behalf of the National Institute of Allergy and Infectious Diseases (NIAID), intends to negotiate and award a firm-fixed-price sole source contract to:
BD Biosciences, Inc. 2350 Qume Drive San Jose, CA 95131 USA
for a service contract to provide preventive maintenance, emergency repair service, replacement parts, labor, travel, software revisions, and technical support for the BD Symphony S6 Flow Cytometer, serial number R66293700030, including associated lasers, for a base year and two option years.
3. Statutory Authority
The Government intends to award this requirement on a sole source basis pursuant to:
41 U.S.C. 152(3), 41 U.S.C. 1901, and FAR 13.106-1(b)(1), soliciting from a single source for purchases at or below the simplified acquisition threshold, as applicable.
This sole source determination is based on the conclusion that only one source is capable of providing the services required at the level of quality required because the services are unique and highly specialized.
4. Description of Requirement
The National Institute of Allergy and Infectious Diseases (NIAID), Division of Intramural Research (DIR), Laboratory of Viral Diseases (LVD), Section of Barrier Immunity, requires a service contract for the BD Symphony S6 Flow Cytometer, serial number R66293700030, and five associated lasers.
The required service coverage includes, at a minimum:
For the BD Symphony S6:
Two (2) preventive maintenance inspections during each contract year, including PM kits; Guaranteed 48-hour response to requests for emergency on-site service; Software revisions released during the agreement term; Unlimited on-site service visits Monday through Friday; and Unlimited telephone support for instruments, reagents, and applications at no additional charge.
For the five associated lasers:
G4 355-60 w/BD UV SAPPHIRE 488-400 Blue MPB 532-1000 SORP Green MPB 628-1000 .3mm Red SORP OBIS 405-100 LX Violet
The required service coverage includes:
Unlimited service visits Monday through Friday; and Repair or replacement as needed.
The anticipated period of performance is January 5, 2027 through January 4, 2030, inclusive of a base year and two option years.
The total estimated value of the requirement, including options, is $250,840.80.
5. Background
The Section of Barrier Immunity within the Laboratory of Viral Diseases conducts research to better understand the mechanisms of HIV/SIV disease progression and to facilitate therapeutic interventions aimed at decreasing microbial translocation and disease progression. The laboratory conducts research on the NIH intramural campus and collaborates with scientists in academic and clinical laboratories nationwide.
A major focus of the Section is the study of cellular HIV/SIV infection in various primate models throughout disease progression and in the context of therapeutic treatments. To study distinct cellular subsets within these models, the laboratory relies extensively on flow cytometric cell analysis for a majority of its research experiments and studies.
The BD Symphony S6 Flow Cytometer was purchased in March 2021 at a cost of $723,265.70 and has been in daily use since that time. Because the instrument is highly sensitive and technically complex, regular preventive maintenance and prompt repair service are essential to ensure reliable operation and continuity of research. Failure to maintain or repair the instrument quickly would negatively impact ongoing studies and jeopardize the Government’s investment in both the equipment and the associated research resources.
6. Sole Source Determination
In accordance with FAR Part 10 and applicable HHS acquisition guidance, market research was conducted for this requirement.
Market research included:
review of required sources; review of Federal Supply Schedules; review of NIH strategic sourcing resources; review of commercial websites and product literature; application of personal knowledge in procuring similar services; contacting knowledgeable individuals in Government and industry regarding market capabilities; participation in online communications among industry, acquisition personnel, and customers; and obtaining source information from other contracting activities, agencies, and commercial sources.
The market research determined that BD Biosciences is the only vendor capable of providing the required service coverage for this instrument at the level of quality required. Specifically, BD Biosciences is the original equipment manufacturer (OEM) of the BD Symphony S6 and is the only source identified that can provide:
OEM-certified service by factory-trained technicians with specialized knowledge of the BD Symphony S6 platform; guaranteed access to OEM replacement parts, components, and modules; software revisions compatible with the instrument throughout the agreement term; unlimited on-site service visits; unlimited telephone support; and a guaranteed 48-hour emergency response time.
Additionally, BD Biosciences confirmed on November 24, 2026 that it is the only vendor authorized to perform maintenance on its equipment.
Accordingly, no other source is known that can satisfy the Government’s requirement without unacceptable risk to instrument performance, research continuity, and data integrity.
7. Procurement History
This is a follow-on requirement for continued service coverage of the BD Symphony S6 Flow Cytometer.
Previous Contractor: BD Biosciences Previous AMBIS Sequence Number: 2250157 Current AMBIS Sequence Number: 2275750 Initial and subsequent awards competed: Yes
The instrument has been covered by service contracts since its original procurement in 2021.
8. Responses from Interested Sources
This notice is not a solicitation. However, any responsible source that believes it is capable of meeting the Government’s requirement may submit a capability statement for consideration.
Interested parties must demonstrate, through clear and convincing documentation, their ability to provide service support equivalent to that described in this notice for the BD Symphony S6 Flow Cytometer and associated lasers.
Capability statements shall include, at a minimum:
company name and address; description of the vendor’s authorization to service the BD Symphony S6; evidence of access to OEM parts, components, and software revisions; documentation demonstrating ability to provide a guaranteed 48-hour on-site response time; description of technician qualifications and training specific to the BD Symphony S6 platform; and explanation of how the vendor will meet each of the Government’s minimum requirements.
Responses must be received no later than December 7, 2026.
Responses shall be submitted electronically to:
Primary Contact: Linda Smith linda.smith2@nih.gov
Secondary Contact: Danielle Tines danielle.tines@nih.gov
The subject line shall reference: Notice Number NIH-NOI-27-PCA-NIAID-12580
9. Government Notice
This notice is provided for informational purposes only and does not constitute a request for proposals, quotations, or bids. The Government does not intend to pay for any information submitted in response to this notice.
All responses received by the closing date will be reviewed by the Government solely for the purpose of determining whether competitive sources exist. A determination by the Government not to compete this proposed action, based upon responses to this notice, is solely within the discretion of the Government.