VA Black Hills seeks radiology equipment testing and radiation monitoring services
Buyer
VA Health Administration Center 23 (VHA NCO 23)
Posted
November 25, 2026
Respond By
December 03, 2026
Identifier
36C26327Q0137
NAICS
811210
The Department of Veterans Affairs is seeking market information for radiology equipment testing and radiation program monitoring at VA Black Hills facilities. - Government buyer: Department of Veterans Affairs, VA Black Hills Health Care System; Network Contracting Office 23. - Opportunity status: Sources-sought market research, not a request for proposals or an award. - Services requested: A board-certified diagnostic radiological physicist to perform annual radiographic and fluoroscopic X-ray equipment certification, dose-rate testing and performance monitoring; sealed-source leak testing twice annually; and testing of newly acquired, repaired, or modified equipment as needed. - Locations: Fort Meade VA Medical Center, Rapid City CBOC, and Hot Springs VA Medical Center. - Quantities: 1 annual equipment testing and monitoring job; 1 leak-testing job for each of two annual rounds; 5 jobs for new-equipment certification and as-needed retesting; and 7 travel-expense units, capped at $2,500 per instance. - OEMs named in the equipment inventory: GE Healthcare, Siemens, Samsung Electronics, Sirona, Dentsply Sirona, Aseptico Inc., Planmeca, Capintec Instruments, Biodex Medical Systems, RadQual, New England Nuclear, and Philips (listed as “Phillips Corp”). - Notable requirements: Follow applicable VA National Health Physics Program guidance and relevant professional standards; furnish leak-test kits, analysis, and reports; and complete required VA training documentation.
Description
Page Information Page 1 of 38Page 14 of 39Page 1 of 38
The VA Black Hills Health Care System—Fort Meade VA Medical Center, Rapid City CBOC, and Hot Springs VA Medical Center locations—is conducting market research in accordance with RFO 17.204-1, Exercise of Options for Equipment Testing and Program Monitoring Services of the Radiology and Quality Programs, as described in the Preliminary Statement of Work below.
This is a SOURCES SOUGHT NOTICE only, looking for businesses to provide the services listed in the Preliminary Statement of Work below for market research purposes. No proposals are being requested or accepted with this notice. THIS IS NOT A SOLICITATION FOR PROPOSALS OR FINAL PRICING, AND NO CONTRACT SHALL BE AWARDED FROM THIS NOTICE. This notice shall not be construed as a solicitation or as an obligation on the part of the Department of Veterans Affairs.
Responses to this notice will be treated only as information for the Government to consider as part of its market research efforts. The information provided will be used by the Government in developing its acquisition strategy regarding possible set-asides for Service-Disabled Veteran-Owned, Veteran-Owned, and other socio-economic categories of small business. Interested parties are responsible for adequately marking proprietary, restricted, or competition-sensitive information contained in their response. The Government does not intend to pay for the information submitted in response to this notice, and parties responding will not be entitled to payment for direct or indirect costs incurred in responding to this notice.
The North American Industry Classification System (NAICS) code for this requirement is 811210, Electronic and Precision Equipment Repair and Maintenance, with an SBA Small Business Size Standard of $34.0 Million.
If you are a vendor capable of providing the requested information and required services described below with competitive pricing, send your information, including a description of proof of capability and answers to all questions, to Alisha.Milander@va.gov on or before Thursday, December 3, 2026, at 12:00 PM Central Time.
Please provide answers as appropriate to the following questions in the table below with your response to this Sources Sought. Failure to respond accurately to the following questions may affect the acquisition strategy. Failure to respond to the questions at all, or to select individual questions, will result in your response being determined as non-responsive.
Please provide all socio-economic categories of your firm (e.g., SDVOSB, VOSB, WOSB, Large Business, 8a, etc.), as well as your firm’s SAM Unique Entity ID number (replaces DUNS number) and Government Contract POC. State whether the requested services may be ordered against a government contract awarded to your organization (e.g., Federal Supply Schedule (FSS), General Services Administration (GSA), etc.). State if subcontracting is contemplated for this requirement, what percentage of the work will be subcontracted, and for what tasks. Provide estimated lead time to deliver a fully functioning solution as described in the Preliminary Statement of Work below. Complete the ITEM INFORMATION directly below this section for market research pricing for the services described in the Preliminary Statement of Work.
Item Information Columns: Item Number; Description of Supplies/Services; Quantity; Unit; Unit Price; Amount
Item 0001 Quantity: 1.00 | Unit: JB | Unit Price: $___________ | Amount: $___________ Perform certification via X-ray equipment testing, dose rate testing, and performance monitoring on radiographic fluoroscopy X-ray equipment for the Black Hills Health Care System during the month of April 2027 in accordance with the Statement of Work. Contract Period: Base POP Begin: 12-15-2026 POP End: 12-14-2027 Principal NAICS Code: 811210 - Electronic and Precision Equipment Repair and Maintenance Product/Service Code: H266 - Equipment and Materials Testing - Instruments and Laboratory Equipment
Item 0002 Quantity: 1.00 | Unit: JB | Unit Price: $___________ | Amount: $___________ Perform leak testing of sealed sources for the Black Hills Health Care System during the month of April 2027 in accordance with the Statement of Work. Contract Period: Base POP Begin: 12-15-2026 POP End: 12-14-2027 Principal NAICS Code: 811210 - Electronic and Precision Equipment Repair and Maintenance Product/Service Code: H266 - Equipment and Materials Testing - Instruments and Laboratory Equipment
Item 0003 Quantity: 1.00 | Unit: JB | Unit Price: $___________ | Amount: $___________ Perform leak testing of sealed sources for the Black Hills Health Care System during the month of October 2027 in accordance with the Statement of Work. Contract Period: Base POP Begin: 12-15-2026 POP End: 12-14-2027 Principal NAICS Code: 811210 - Electronic and Precision Equipment Repair and Maintenance Product/Service Code: H266 - Equipment and Materials Testing - Instruments and Laboratory Equipment
Item 0004 Quantity: 5.00 | Unit: JB | Unit Price: $___________ | Amount: $___________ Perform certification via X-ray equipment testing, dose rate testing, and performance monitoring as requested on all newly acquired radiographic fluoroscopy X-ray equipment for the Black Hills Health Care System throughout the period of performance. Also perform follow-up testing on existing equipment on an as-needed basis when repairs are made or equipment is changed out requiring re-testing, in accordance with the Statement of Work. Contract Period: Base POP Begin: 12-15-2026 POP End: 12-14-2027 Principal NAICS Code: 811210 - Electronic and Precision Equipment Repair and Maintenance Product/Service Code: H266 - Equipment and Materials Testing - Instruments and Laboratory Equipment
Item 0005 Quantity: 7.00 | Unit: EA | Unit Price: $___________ | Amount: $___________ Travel expenses to perform services in accordance with the Statement of Work. Not to exceed $2,500 per instance. Contract Period: Base POP Begin: 12-15-2026 POP End: 12-14-2027 Principal NAICS Code: 811210 - Electronic and Precision Equipment Repair and Maintenance Product/Service Code: H266 - Equipment and Materials Testing - Instruments and Laboratory Equipment
Preliminary Statement of Work
Introduction The Black Hills Health Care System, Facilities Management Department requires a Board Certified diagnostic radiological physicist to perform equipment testing and program monitoring services of the radiology and quality programs at the Fort Meade VA Medical Center, Rapid City CBOC, and Hot Springs VA Medical Center locations. The Board Certified diagnostic radiological physicist shall have the capability to support and service all listed radiographic/fluoroscopic X-ray equipment and also provide certification, as requested, of all newly acquired radiographic/fluoroscopic X-ray equipment throughout the period of performance of the contract and all exercised option years.
Requirements General The Contractor shall provide a Board Certified diagnostic radiological physicist to perform equipment testing as specified in Paragraph 2.b. for all necessary equipment in April of each year (see Paragraph 2.d. Equipment Listing) and program monitoring services of the radiology and quality programs at the Fort Meade VA Medical Center, Rapid City CBOC, and Hot Springs VA Medical Center locations. Services requested also include leak testing of sealed radiation sources as specified in Paragraph 2.c. in April and October of each year for specified equipment (see Paragraph 2.d. Equipment Listing). Additional services include follow-up testing and certification on existing equipment on an as-needed basis when repairs are made or equipment is changed out and requires certification prior to use.
Radiographic Fluoroscopic X-ray Equipment Testing, Dose Rate Testing and Performance Monitoring (all April frequency cycle items in list below) Testing and monitoring will conform to current VHA National Health Physics Program (NHPP) guidelines as noted in the references below. Testing will include, but not be limited to: Measurement of radiation output parameters, including beam filtration. Testing of automatic control systems, such as automatic exposure controls of radiographic systems and automatic exposure rate controls of fluoroscopy systems. Assessment of image quality. Measurement of appropriate indices of patient doses or dose rates at clinical technique factors, with comparison to national standards. Measurement of minimum detectable activity of the Thyroid Uptake unit.
Monitoring will include, but not be limited to: A review of the quality control monitoring performed by technologists. The design will conform to the ACR Technical Standard for Diagnostic Medical Physics Performance Monitoring of Radiologic and Fluoroscopic Equipment and the ACR Technical Standard for Diagnostic Medical Physics Performance Monitoring of Computed Tomography (CT) Equipment, available from the American College of Radiology. Appropriate indices of doses to patients, as estimated by the diagnostic radiological physicist for the technique factors used at the facility, must be posted at or near the control console for each X-ray imaging device. For radiographic equipment, the entrance skin exposure, air kerma, or dose for a patient of typical size must be posted for common radiographic procedures. For fluoroscopic equipment, the entrance skin exposure rate, air kerma rate, or dose rate must be posted for a typical range of patient sizes for common modes of operation, including various image magnification factors, “boost mode,” if available, continuous fluoroscopy, and pulsed fluoroscopy at the available pulse rates. For fluoroscopic equipment, the dose per image for each mode of image recording shall also be posted for a patient of typical thickness.
Leak Testing of Sealed Sources (all April/October frequency cycle items in Paragraph 2.d. Equipment Listing) Testing and recordkeeping requirements: Each licensee who uses a sealed source shall have the source tested for leakage periodically. The licensee shall keep a record of leak test results in units of micro curies and retain the record for inspection. Method of testing: The wipe of a sealed source must be performed using a leak test kit. The wipe sample must be taken from the nearest accessible point to the sealed source where contamination might accumulate. The wipe sample must be analyzed for radioactive contamination. Test frequency: Each sealed source (except an energy compensation source (ECS)) must be tested at intervals listed (April/October). The Radiation Physicists will provide the wipe test kits, the analysis, and the required report.
Equipment Listing Page 1 of 38Page 15 of 39Page 1 of 38 Columns: Frequency; Facility; Room #; Nomenclature; Manufacturer; Model; Serial Number; VA AEMS MERS ID Apr | FM | 217A-145 | RADIOG-FLUORO IMAGING SYST (R/F) | GE Healthcare | OEC ELITE | FBXXTE02427 | 568 MX3387487 Apr | FM | CS201I-113 | R/F UNITS: MOBILE, OEC ELITE CFD (CART) | GE Healthcare | OEC ELITE CFD | FBXXTE03024 | 568 MX3580117 Apr | FM | S222-113 | R/F UNITS: MOBILE, OEC ELITE CFD (CART) | GE Healthcare | OEC ELITE CFD | FBXXTE03025 | 568 MX3580118 Apr | FM | CS201I-113 | R/F UNITS: MOBILE, OEC ELITE CFD (C-ARM) | GE Healthcare | OEC ELITE CFD | X0034828007971 | 568 MX3580488 Apr | FM | S222-113 | R/F UNITS: MOBILE, OEC ELITE CFD (C-ARM) | GE Healthcare | OEC ELITE CFD | X003482007868 | 568 MX3580489 Apr | FM | 104-265 | MRI | Siemens | Magnetom Sola | 183215 | MX2583351 Apr | FM | 148-113 | CT | Siemens | Definition AS | 96286 | MX665120 Apr | FM | 154-113 | Spec-CT | GE Healthcare | Optima NM/CT640 | 640Y25559 | MX2037514 Apr | FM | 143-113 | Radiographic Systems | Samsung Electronics | GC85A | 52RNM3RM900001J | MX2040652 Apr | FM | 143-113 | Radiographic Systems | Samsung Electronics | GC85A | 55EVM3EM7000001W | MX2287241 Apr | FM | 143-113 | R/F System | Siemens | Axiom Luminous agile | 61059 | EE43067 Apr | FM | 143-113 | x-ray mobile | Samsung Electronics | GM85 | 55GFM31M400011K | MX1973107 Apr | FM | 143-113 | x-ray mobile | Samsung Electronics | GM85 | 55GFM31M400012E | MX1973112 Apr | FM | 313OP2-145 | xray Dental Intraoral | Sirona | Heliodent plus | 17647 | EE38836 Apr | FM | 313OP3-145 | xray Dental Intraoral | Sirona | Heliodent plus | 31019665 | MX663076 Apr | FM | 317-145 | xray handheld intraoral | Aseptico Inc | Nomad pro 2 | 1001091 | MX1882089 Apr | FM | 318-145 | xray Panolypse | Planmeca | Promax S3 PAN | TPX356791 | EE38863 Apr | FM | 155-113 | Dose Calibrator | Capintec Instruments | CRC-25R | 250014 | EE28935 Apr | FM | 156-113 | Thyroid Uptake System | Biodex Medical Systems | HIT-W151 | KSA1590781 | MX419236 Apr/Oct | FM | 155-113 | Cs137 .0001 curies | Capintec Instruments | CR-15E | S8117001-06 | none Apr/Oct | FM | 155-113 | Ba133 .000231 curies | Capintec Instruments | CR-178E | S8107001-04 | none Apr/Oct | FM | 155-113 | Co57 .99561 curies | RadQual | BM06E | BM06057E11278103 | none Apr | FM | 127-113 | Densitometers: Bone: X-Ray | GE Healthcare | Lunar IDXA | 213130MA | MX3495174 Apr | RCBOC | Mobile | Mobile MRI | Siemens | Magnetom AERA | 142349 | MX2067566 Apr | RCBOC | 1910 | Radiographic System Digital | Phillips Corp | Digital Diagnost C90 | 22860092 | MX2991885 Apr | HS | D020-12 | Mobile Scanning Systems: CT | Siemens | SOMATOM DEFINITION AS | 95402 | EE43219 Apr | HS | B006-12 | R/F System | Siemens | Axiom Luminous agile | 61237 | MX423229 Apr | HS | B002-12 | Radiology System | Samsung Electronics | GC85A | 52RNM3FM500001N | MX2047221 Apr | HS | B002-12 | xray portable | Samsung Electronics | GM85 | 55GFM31M4000014D | MX1980227 Apr | HS | D112A-12 | xray Panolypse | Planmeca | Promax S3 PAN | TPXV3062268 | MX1655374 Apr | HS | D112B-12 | xray Dental Intraoral | dentsply Sirona | Heliodent plus | 63217 | MX1958839 Apr | HS | D112C-12 | xray Dental Intraoral | dentsply Sirona | Heliodent plus | 63234 | MX1958841 Apr | HS | D112E-12 | xray Dental Intraoral | dentsply Sirona | Heliodent plus | 63209 | MX1958843 Apr/Oct | FM | 155--113 | CSs137 .000199 Curies | New England Nuclear | NES 356 | 3560180A-50 | None Apr/Oct | FM | 155-113 | Co60 .00005 curies | New England Nuclear | NES 354 | 3540579A-49 | none Apr/Oct | FM | 155-113 | Ba133 .00029 curies | New England Nuclear | NES 358 | 3580479A-02 | None Apr/Oct | FM | 155-113 | Co57 | RadQual | BM06E-57 | BM6057E12083117 | None Apr/Oct | FM | 155-113 | Co57 | RadQual | BM01-10 | BM011012088101 | None
Training Requirements Appropriate vendor staff (as determined by the VA) performing the duties of the Statement of Work shall complete (print, review, and sign) the attached TMS 20939 “No Access” document. The Contractor shall send signed TMS 20939 documents to the Contracting Officer’s Representative, Jonathan Maruszewski, at jonathan.maruszewski@va.gov.
Security The Contractor shall adhere to only the following IT security sections contained in the IT Contract Security Clause below (VHA Handbook 6500.6): General
Working Hours Anticipated hours of work will be Monday through Friday from 7:00 am–4:00 pm. Additional hours must be coordinated through the COR/POC. Work will not be performed on weekends or federal holidays.
Observed Federal Holidays New Year’s Day Martin Luther King Birthday Washington’s Birthday Memorial Day Juneteenth Independence Day Labor Day Columbus Day Veteran’s Day Thanksgiving Day Christmas Day
References NHPP X-ray imaging guidance: http://nhpp.med.va.gov/NHPP_Diagnostic_Radiology_Info.asp ARC Technical Standard for Diagnostic Medical Physics Performance Monitoring of Computed Tomography (CT) Equipment. ARC Technical Standard for Diagnostic Medical Physics Performance Monitoring of Radiological and Fluoroscopic Equipment. NCRP Report #102 - Medical X-ray, Electron Beam and Gamma-Ray Protection for Energies up to 50MeV (Equipment Design, Performance and Use). NCRP Report #147 - Structural Shielding Design for Medical X-ray Imaging Facilities. NCRP Report #99 - Quality Assurance for Diagnostic Imaging Equipment. NRC NUREG 1556, Volume 9 - Program-Specific Guidance About Medical Use Licenses. Joint Commission Compliance Checklist: Diagnostic Imaging Standards: EC.02.01.01 - PI.02.01.01.