Opportunity
SAM #36C24127Q0091
VA Boston planned sole-source medical oxygen cylinder supply and maintenance
Buyer
Department of Veterans Affairs
Posted
November 24, 2026
Respond By
November 30, 2026
Identifier
36C24127Q0091
NAICS
532490
The VA Boston Healthcare System is seeking vendor capability information for a planned sole-source medical oxygen cylinder supply and service contract with Airgas USA, LLC. - Buyer: Department of Veterans Affairs, VA Boston Healthcare System, Network Contracting Office 01. - Planned contractor: Airgas USA, LLC. The VA cites Airgas’s ownership of existing oxygen station tanks and the cost, disruption, and safety implications of replacing them as the basis for its proposed sole-source approach. - Locations and stated quantities: West Roxbury requires 3,429 standard aluminum E cylinders, 483 MRI-safe aluminum E cylinders, and 43 steel H cylinders; Jamaica Plain requires 3,429 standard E cylinders and 33 H cylinders; Brockton requires 3,429 standard E cylinders and 33 H cylinders. - Technical requirements: E cylinders must have integrated valves; H cylinders must use the Diameter Index Safety System (DISS). Regulators must provide a 50-psi outlet and specified oxygen flow settings from 0.25 to 25 liters per minute, with continuous flow between settings, an integrated single valve/regulator, and a rupture-disk relief valve. - Services: Furnish and maintain cylinders; deliver twice weekly, generally Mondays and Thursdays; respond to emergencies within two hours and non-emergency calls within 24 hours or the next business day; repair minor leaks and provide leak-test and repair reports. Holiday delivery is shifted to the next business day after a needs assessment. - Response opportunity: Interested vendors may submit written capability information for VA consideration. This notice is not a solicitation or request for proposal.
Description
The Department of Veterans Affairs, Networking Contracting Office (NCO 01) located in Brockton, MA intends to enter into a sole source procurement, pursuant to the authority of FAR 6.302-1, with Airgas USA, LLC, for the following requirement:
Statement of Work General:
The contractor will provide delivery of all requirements for individual compressed gas cylinders/tanks to the locations listed in this document.
Period of Performance: base year plus one option year Base year: January 1, 2027 - December 31, 2027 Option year one: January 1, 2028 December 31, 2028
Intended Use:
To meet the needs for patients requiring oxygen therapy during transport to different locations of the Boston VA Healthcare System within the facilities. The requirement of the following are estimated amount of each specific size, type of material the cylinder is manufactured of, cylinders with integrated regulators and handles.
Integrated valve stem regulator with the aluminum cylinder are utilized throughout Boston Healthcare System.
Boston VA Healthcare System requires that all of the hospital transport cylinders be light weight cylinders with integrated regulator with wide handle that is secured to the regulator that extends upward for ease of carrying. The integrated regulator must be able to deliver a flow rate of 0.25, 0.5, 1, 2, 3, 4, 6, 8, 10, 15, 25 liters per minute flow. The regulator also must provide a 50 psi outlet port to connection to equipment if needed.
Boston VA Healthcare System requires that of the hospital MR compatible transport cylinders be light weight cylinders with integrated regulator with wide handle that is secured to the regulator that extends upward for ease of carrying. The integrated regulator must be able to deliver a flow rate of 0.25, 0.5, 1, 2, 3, 4, 6, 8, 10, 15, 25 liters per minute flow. The regulator also must provide a 50 psi outlet port to connection to equipment if needed.
Boston VA Healthcare System requires that all H cylinders are made of Steel with the Diameter Index Safety System. These cylinders are utilized for Emergency Back Up during an oxygen failure or shut down.
Place of Performance: West Roxbury VA Medical Center 1400 VFW Pkwy, West Roxbury, MA 02132 Jamaica Plain VA Medical Center 150 South Huntington Ave, Boston, MA 02130 Brockton VA Medical Center 940 Belmont St Brockton, MA 02301
Day and Hours of Operation:
West Roxbury VA Medical Center: M-F 0800-1600 or after regular duty hours by calling the respiratory care department for access. Jamaica Plain VA Medical Center: M-F 0800-1600 Brockton VA Medical Center: M-F 0800-1600
Performance Requirements:
The contractor must be able to supply the facilities listed above with the medical grade compressed gases listed in Section 8 weekly.
Specifically- deliveries are to be made to West Roxbury campus every Monday and Thursday without fail excluding holidays at which point a needs assessment will be completed and the company will push delivery to the next business day.
Deliveries will be made twice per week at the Jamaica Plain campus every Monday and Thursday following the same protocol as West Roxbury.
Deliveries will be made twice per week at the Brockton campus following same scheduling and protocol as West Roxbury.
The contractor will respond to emergency calls within 2 hours.
The contractor shall respond to non-emergency call within 24 hours or the next business day.
The contractor shall repair all minor cylinder leaks detected and provide a full report of leak tests and any leaks repaired to the Contracting Officer s Representative (COR).
Patient and occupation safety require that all tanks meet all regulatory guidelines and the tanks and regulators allow continuous oxygen flow between regulator settings.
Safety features include:
Oxygen flow that does not stop if the regulator is placed between two numbers.
Integrated valve and regulator that is built into tank and doesn t need to be installed by staff.
Single valve tank. No tanks with two valves, this is a human factor safety risk. National Center for Patient Safety discourages any two valve tanks.
Rupture disk relief valve.
50 PSI DISS outlet that delivers up to 200 lpm if needed for mechanical ventilator device.
Invoices:
Invoicing is required to be submitted per delivery. Payment will be made upon receipt of a properly prepared detailed invoice, prepared by the contractor, validated by the contracting officer s representative (COR) and submitted. A properly prepared invoice will contain: Invoice number and date Contractor s name and address Contract number Accurate purchase order number Itemized supply or service provider Total amount due
Medical Gases and Supplies to be Provided:
West Roxbury Location Furnish and maintain 3429 E cylinder made of aluminum with integrated valve. Furnish and maintain 483 MRI safe E cylinder made of aluminum with integrated valve. Furnish and maintain 43 H cylinder made of steel using DISS system. Jamaica Plain Location Furnish and maintain 3429 E cylinder made of aluminum with integrated valve. Furnish and maintain 33 H cylinder made of steel using DISS system Brockton Location Furnish and maintain 3429 E cylinder made of aluminum with integrated valve Furnish and maintain 33 H cylinder made of steel using DISS system
The NAICS code for this requirement is 532490.
Airgas USA, LLC is the only vendor capable of providing the required services as they presently have liquid oxygen tanks located at all three(3) facilities within the Boston Healthcare System; they also have backup reserves at these facilities (3 in Brockton, 1 in West Roxbury, 1 at JP). The station tanks are owned by Airgas USA, LLC and proprietary to their oxygen supply. Due to liability issues, it is not permissible or legal for a contractor other than Airgas to fill or maintain the tanks owned by Airgas. Airgas provides annual inspections and preventative maintenance on the station tanks at no additional cost to the government and provides reports on operation and condition to each facility. If the new requirement were to be awarded to another company, the existing station tanks would need to be removed from each VA Facility. The cost of removal alone is estimated by the incumbent contractor to be upwards of $45,000.00 which does not include installation of new tanks. If another vendor was awarded this requirement, the supplier of the oxygen itself would need to change as Airgas will fill and maintain tanks owned only by Airgas. The removal and replacement of station tanks would be cost prohibitive to the amount of funding allocated by the VA Boston Healthcare System for this service, would require numerous labor hours across multiple VA departments to coordinate, supervise, receive and test the replacement and would create a disruption in the provision of bulk oxygen to the facility. The lapse of medical gasses to the Boston Healthcare System would require the coordination of multiple medical departments within each facility to ensure patient care is not impacted. Installing out a new system would impinge clinical service as alternative delivery sources would have to be established for the period of system change out. The tanks currently are meeting current demands and meet all the demands of the Boston VA health care needs. Concrete pads currently in place would have to be reconfigured and additional contracts would need to be in place with construction in order to have this done. The current plumbing situation would have to be replaced and reconfigured to meet specs of new tanks. This also would incur additional costs with a new service contract. The Boston VA Healthcare system would have to supply alternative source of oxygen during all above and would necessitate great cost for supplies, labor and other variable costs.
This notice of intent is not a solicitation nor is it a request for proposal. However, interested parties that believe they can satisfy the requirement listed above must clearly identify their capability to do so in writing by November 30, 2026 at 12 pm EST time. Responses should be sent to Issa Shawki at issa.shawki@va.gov. Information submitted in response to this notice will be used solely to determine whether competitive procedures could be used for this acquisition. A determination not to open the requirement to competition based upon responses to this notice is solely within the discretion of the Government.