Opportunity

SAM #1240BE27Q0025

Forest Service HVAC Work: Seal 37 FCU Vents and Repair Mitsubishi VRF System

Buyer

USFS Southern Research Station

Posted

November 20, 2026

Respond By

December 01, 2026

Identifier

1240BE27Q0025

NAICS

238220

The USDA Forest Service is seeking HVAC work at its Durham, North Carolina, research facilities. - Government buyer: U.S. Department of Agriculture (USDA), Forest Service, CSA Northwest 3; buyer contact: Jared Machgan. - OEM: Mitsubishi — the existing VRF system is model PURY-P120TLMU-A, serial 79W00897, rated at 10 tons and using R-410A refrigerant. - Requested services: - Block and seal all 37 outside-air vents serving fan coil units (FCUs) in the main laboratory building; verify the seals prevent air entry and test the FCUs. - Diagnose the Mitsubishi VRF system’s failure to maintain setpoints, inspect for refrigerant leaks at line-set connections and indoor and outdoor units, provide labor and material pricing for approval, and test and calibrate components after approved repairs. - Notable requirements: The work covers the Forestry Sciences Laboratory and Forest Science and Assessment Center in Durham, North Carolina. Work must begin within 30 calendar days and be completed within 60 calendar days after the Contracting Officer authorizes it. - Set-aside: Total small business.

Description

This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Part 12.  This announcement constitutes the only solicitation.  Quotations are being requested and a separate written solicitation will not be issued. 

Solicitation number 1240B27Q0025 is issued as a Request for Quotation (RFQ) for Research Triangle Park Forestry Sciences Laboratory HVAC Repair

This acquisition  is set-aside for small business concerns.  The applicable North American Industry Classification Standard Code is 238220  The small business size standard is $19 M  This acquisition is a Total Small Business Set-Aside.  All responsible sources may submit a quotation which will be considered by the agency. 

The primary HVAC system (ACCU-1/VRV 2-7) for the Forest Science and Assessment Center (FSAC) is a Mitsubishi VRF system (BHM06227, Model PURY-P120TLMU-A, Serial 79W00897, 10 tons, R-410A) with 6 interior units. The system does not maintain condition set points and an initial evaluation during a preventative maintenance service call diagnosed with a potentially significant refrigerant leak.

The Forestry Science Laboratory (FSL) building’s Fan Coil Units (FCUs) are redundant in the current HVAC system. The outside air vents are no longer needed and are introducing unconditioned air into the building. During cold weather, this can lead to the coils potentially freezing and have led to the freeze-stats tripping, resulting in nuisance shutdowns.

View original listing