238220

The Department of Veterans Affairs is considering a sole-source maintenance and support contract for the installed Trane building-controls system at the West Roxbury VA Medical Center. - Agency and approach - VA Boston Healthcare System, through Networking Contracting Office 01 (NCO 01), intends to award to Trane U.S. Inc. - This is a notice of intent, not an award. Interested firms may submit capability information for the Government to assess whether competition is feasible. - Equipment and scope - The attachment itemizes 33 Trane Tracer SC/SC+ controllers, model X136516950: 30 Tracer SC+ units and 3 Tracer SC units. - Maintenance covers controls for air-handling, chilled-water, condenser-water, hot-water, miscellaneous I/O, and rooftop-unit systems; loop tuning; sequence-of-operation checks; sensor calibration; system and VAV front-end analysis; backups; and programming verification. - Trane-specific software and firmware updates, SC+ SMP licensing, and Ensemble software and cloud-subscription support are included. - Pricing and performance requirements - The contemplated term is one base year plus two option years; no specific start or end dates are stated. - Routine specified preventive maintenance is to be firm-fixed-price, with annual pricing itemized per visit and covered equipment item. Corrective repairs, replacements, emergency service, and other out-of-scope work require separate authorization and are billed separately. - Technicians must have relevant recent experience and factory training credentials. The contractor must have at least five years of comparable maintenance experience and access to OEM parts. - The attachment summary states 35 units, while its equipment list contains 33 entries and the initial release also identifies 33; the itemized list is reflected here.

Description

The Department of Veterans Affairs, Networking Contracting Office (NCO 01), located in Brockton, MA, intends to enter into a sole-source procurement, pursuant to the authority of FAR 6.302-1, with TRANE U.S. Inc., for the following requirement:

Statement of Work Scope of Work The Contractor shall provide all supervision, personnel, material, parts, equipment, supplies, labor, and transportation in performing basic intelligent services on the Trane Building Control Units located at the Department of Veterans Affairs Medical Center, 1400 VFW Parkway, West Roxbury, MA 02132, in accordance with all terms and conditions of this contract. Period of Performance: One base year plus two option years.

Definitions/Acronyms Contract Discrepancy Report (CDR): A report that the Government shall complete and issue to the Contractor when service is unsatisfactory and not in compliance with the terms and conditions of the contract. The Contractor is required to complete and return this form to the COR whenever performance is unsatisfactory. The CDR requires the Contractor to explain, in writing, the cause of the unsatisfactory performance, how performance will be returned to acceptable standards, and how reoccurrence of the problem will be prevented in the future. Contracting Officer (CO): The individual with the authority to enter into, administer, and/or terminate contracts. The CO is the exclusive Government official authorized to execute changes and deviations or variations in the contract. Contracting Officer's Technical Representative (COTR): A Government representative, designated in writing by the Contracting Officer, to be responsible for quality assurance, inspection, surveillance, documentation, and acceptance of the Contractor's performance. A copy of the letter of designation will be provided to the Contractor. Preventive Maintenance (PM): Services which are periodic in nature and are required to maintain the equipment in such condition that it may be operated in accordance with its intended design and functional capacity with minimal incidence of malfunction or inoperative conditions. This includes cleaning, lubricating, calibrating, testing, and replacing faulty or worn parts and/or parts which are likely to become faulty, fail, or become worn; repairing or adjusting components or assemblies of components as necessitated by wear, tear, damage, or failure of parts; and returning the equipment and/or instrument to the operating condition defined in the manufacturer's specifications. Repair Cost Estimate: The Contractor's estimated cost (for parts, labor, and freight) to repair a system according to manufacturers' specifications and requirements. Time: When hours are given, they shall mean clock hours exclusive of Saturdays, Sundays, and holidays unless otherwise specified (i.e., 1:00 P.M. Monday to 1:00 P.M. Tuesday equals 24 hours; 12:00 P.M. Friday to 12:00 P.M. Monday equals 24 hours). If days are indicated, they shall mean calendar days including Saturdays, Sundays, and holidays. Rework: Any work the Contractor is required to accomplish due to unsatisfactory performance or nonperformance in accordance with the stated quality and level of effort specified in the contract. Rework is performed at no additional cost to the Government. ESR: Vendor Engineering Service Report. Documentation of services rendered for each incidence of work performance under the terms and conditions of the contract. Acronyms: Commonly used acronyms are listed below: FSE: Field Service EngineerAQL: Acceptable Quality LevelIAW: In Accordance WithQA: Quality AssuranceQC: Quality ControlWS: Performance Work StatementVA: VA Medical CenterCO: Contracting OfficerCOTR: Contracting Officer's Technical RepresentativeFES: Facilities and Engineering Service

Preventive Maintenance Requirements Within 14 calendar days of Notice to Proceed, the vendor will submit to the COTR a written schedule of the planned PM visits for the coming year along with a written description of the work to be performed during each visit. Refer to paragraph IV.B. below for schedule and inspection requirements. Each inspection will be provided in accordance with the system/equipment manufacturer's factory-recommended procedures. Each inspection shall, at a minimum, include the following as specified for the equipment make, type, and time of seasonal operation. Any additional parts not identified in this document will not be covered by this contract. The vendor will obtain prior approval from the COTR prior to performing any additional repair work, and the additional work will be billed separately. For each PM inspection, the Contractor will provide a detailed written report to the COTR that summarizes work performed, problems/deficiencies found, and measurements taken. This report will be submitted within 10 calendar days of the date of PM inspection. All work will be performed between the hours of 7:30 a.m. and 4:00 p.m. on the prearranged dates. The Contractor shall perform preventive maintenance and technical support services on the equipment identified in the contract's covered equipment schedule in accordance with manufacturer-recommended procedures and the service activities specifically identified in the Statement of Work. Within 14 calendar days of Notice to Proceed, the Contractor shall submit a proposed annual maintenance schedule identifying the covered equipment, planned service activities, service frequency, and anticipated dates of performance. The minimum required service frequencies and quantities shall be established in the contract prior to award. Upon completion of each scheduled maintenance activity, the Contractor shall provide a written service report documenting the equipment serviced, inspections and tests performed, software or programming adjustments completed, deficiencies identified, and recommendations for corrective action. Routine preventive maintenance, software updates, licensing services, and controls verification specifically identified in the contract shall be included in the established Firm-Fixed-Price. Corrective repairs, equipment replacement, emergency service, and other work not expressly included in the contract shall require separate authorization by the Contracting Officer before performance. The COR may coordinate and review proposed corrective work but does not have authority to obligate additional Government funds or direct out-of-scope services. All inspection work must be coordinated through the COTR. The following is the scope of services to be performed on Covered Equipment.

Equipment Maintenance Procedures The following “Covered Equipment” will be serviced at VA Medical Center W Roxbury: EquipmentQtyManufacturerModel NumberSerial NumberAsset Tag Tracer SC+1TraneX136516950E20M13318SC-1 Tracer SC+1TraneX136516950E22B22087SC-2 Tracer SC+1TraneX136516950E22B22088SC-3 Tracer SC+1TraneX136516950E22A00251SC-4 Tracer SC+1TraneX136516950E23F18569SC-5 Tracer SC+1TraneX136516950E22A00814SC-7 Tracer SC+1TraneX136516950E21M06737SC-8 Tracer SC+1TraneX136516950E22A00815SC-9 Tracer SC+1TraneX136516950E22A00242SC-10 Tracer SC+1TraneX136516950E22A00241SC-11 Tracer SC+1TraneX136516950E22A00827SC-12 Tracer SC+1TraneX136516950E22A00837SC-13 Tracer SC+1TraneX136516950E22A00835SC-14 Tracer SC+1TraneX136516950E22A00252SC-15 Tracer SC+1TraneX136516950E22A00836SC-16 Tracer SC1TraneX136516950E14L83619SC-18 Tracer SC1TraneX136516950E15B81289SC-19 Tracer SC+1TraneX136516950E23L10270SC-20 Tracer SC1TraneX136516950E16K91711SC-21 Tracer SC1TraneX136516950E16F88171SC-22 Tracer SC+1TraneX136516950E20E01214SC-23 Tracer SC1TraneX136516950E17F91510SC-24 Tracer SC+1TraneX136516950E24M68068SC-25 Tracer SC+1TraneX136516950E21H01208SC-26 Tracer SC+1TraneX136516950E23F18570SC-27 Tracer SC+1TraneX136516950E23F18580SC-28 Tracer SC+1TraneX136516950E23F18581SC-29 Tracer SC+1TraneX136516950E23F18574SC-30 Tracer SC+1TraneX136516950E23F18578SC-31 Tracer SC+1TraneX136516950E23F18577SC-32 Tracer SC+1TraneX136516950E23F18582SC-33 Tracer SC+1TraneX136516950E23F18579SC-34 Tracer SC+1TraneX136516950E23F18573SC-35

Customer Service Flows The following Customer Service Flows provide additional service description detail for Covered Equipment. Note: There may be differences per the agreement in the work being performed between sites and the equipment on those sites. This section clarifies differences in the work being performed between sites and the equipment on those sites. Service 1: AHU Controls SupportLoop TuningSequence of Operation Verification Service 2: Chilled Water System Controls SupportLoop TuningSequence of Operation Verification Service 3: Condenser Water System Controls SupportLoop TuningSequence of Operation Verification Service 4: Hot Water System Controls SupportLoop TuningSequence of Operation Verification Service 5: Miscellaneous I/O SupportSequence of Operation Verification Service 6: RTU Controls SupportLoop TuningSequence of Operation Verification for Service 7: Software UpdatesUpdate SC+ SMP LicenseFirmware UpdateOn-Site Ensemble Software UpdatesUpdate Ensemble Cloud Subscription Loop tuning Develop/review list of associated points and associated control loopsReview set point is at appropriate value for applicationTest control loop by modifying set point and confirming algorithm responds at appropriate speed of response and stabilityDocument changes Sequence of operation verification Review sequence of operations for system according to associated documentationConnect to systems controller and confirm baseline programs are functioningReview and document any manual overrides, discuss with operator, and attempt to release override and enable operation as appropriateReview and document failed sensors and communications errorsReview system schedule with system operator, make changes as appropriateDocument changes Service 8: Sensor CalibationCalibrate Temperature SensorsCalibrate Air Differential Pressure SensorsCalibrate Humidity SensorsCalibrate Duct SensorsCalibrate Airflow Stations Service 9: System Analysis and ReviewOparator Workstation InspectionSystem Controller InpectionVerify Software System ProgrammingSystem BackupCustomer Review 30 MinutesSoftware Service Pack Update Service 10: System VAV Front-End AnalysisVAV Front-End Analysis

Emergency Service Emergency repair service is not covered by the contract. However, the Contractor will provide a preferred customer response to emergency repair calls that includes labor and parts costs to be billed separately.

Contractor Personnel Personnel Experience. All work shall be performed by competent mechanics, experienced and qualified to work on the specific makes and models of equipment listed in this contract. The Contractor shall submit to and for the approval of the Contracting Officer, certification and a list of credentials of the approved mechanics. Personnel shall have a minimum of three (3) years' recent experience related to this work. The Contractor must provide a list of three (3) reference contacts that have been provided service on similar or identical equipment. The Contractor must provide authenticated factory training certificates or credentials (or acceptable substitute as approved by the COTR) for any personnel who are working on any VA equipment. The VA specifically reserves the right to reject any of the Contractor's personnel and refuse them permission to work on VA equipment. Conduct of Personnel. The Contractor shall ensure that its personnel present a professional appearance at all times and that their conduct shall not reflect discredit upon this facility or the Department of Veterans Affairs. The Contractor shall remove from the job site any employee for reasons of misconduct or security. The removal from the job site of such a person shall not relieve the Contractor of the requirement to provide sufficient personnel to perform adequate and timely service. All employees shall be legal residents of the United States and be able to understand, speak, read, and write the English language. Identification of Employees. The Contractor shall, within 10 calendar days before beginning performance of work, provide the Contracting Officer a list of all employees who will perform under this contract. The list shall include the full name and work assignment of each employee. The Contractor shall notify the Contracting Officer in writing of any addition, deletion, or change in work assignment within 10 days of such change. Each of the Contractor's employees shall conspicuously display on their person a badge provided by the VA West Roxbury Police Office.

Hours of Operation Normal Duty Hours. The Contractor shall have employees available Monday through Friday, except legal public holidays, at the times specified to perform routine work and inspections. Federal Holidays. Federal holidays observed by the VA are: New Year's Day; Martin Luther King Day; President's Day; Memorial Day; Independence Day; Labor Day; Columbus Day; Veterans Day; Thanksgiving Day; and Christmas.

Contractor Quality Control The Contractor shall establish and maintain a Quality Control Program that ensures that all requirements of the contract are provided as specified.

Inspection and Acceptance Final inspection and acceptance by the Government shall be made at the site of each system. However, final inspection and acceptance do not preclude the Government's right to inspect completed work prior to shipment from the Contractor's shop, nor does it waive any rights of the Government. Unsatisfactory service will be reported in writing by the VA CO to the Contractor. Telephone Answering Service: The Contractor shall maintain, at its own expense, a dedicated (tie-line) toll-free telephone answering service for the exclusive use in the performance of this contract. This answering service shall be monitored during normal work hours as identified in the specifications.

Removal and/or Disposal Removing Government-Owned Material: All property removed remains the property of the U.S. Government and shall be returned by the Contractor to a place of storage as designated by the CO or COTR. Salvage: Items received by the Contractor that are non-repairable because of condition, or declared unfit for economical rehabilitation by the Contractor, shall be returned to the Government. All salvage remaining in the Contractor's shop shall remain Government property and may be used for repair of any Government-owned equipment when released by the CO. The Contractor shall be required to maintain an account record of inventory upon completion of the maintenance contract. Inventories shall not be disposed of by the Contractor without inspection and written approval of the CO. Salvaged parts used in the repair of any Government-owned equipment shall be treated by the Contractor as Government-furnished material and reflected as same on Contractor's invoices when submitted for payment. All salvage in the possession of the Contractor, upon expiration of the contract, will be returned to the Government within thirty (30) days after such expiration.

Fire Prevention and Protection The Contractor shall fully acquaint itself and its personnel with the location of fire equipment before work, take all prudent measures to minimize fire hazards that result from work, and comply with all ordering agency fire and safety regulations.

Energy Conservation The Contractor is required to comply with all energy conservation regulations and instructions that are applicable to Government-owned facilities, including but not limited to thermostat settings.

Cleaning Up The Contractor shall clean up after work, leaving each area where work is performed neat and clean. All containers, trash, and debris for which it is responsible shall be removed.

Hazardous Conditions During the course of performing work under this contract, should the Contractor find serious or hazardous conditions existing with or in any of the equipment, the Contractor shall secure the equipment and immediately notify the COTR.

Cleanliness The area immediately around the equipment provided for the Contractor's use shall be kept in a clean and orderly condition. Trash and waste material shall not be permitted to accumulate but shall be removed by the Contractor's employees.

Service Manuals The VA shall not provide service manuals or service diagnostic software to the Contractor. The Contractor shall obtain, have on file, and make available to its FSEs all operational and technical documentation (such as operational and service manuals, schematics, and parts lists) necessary to meet the performance requirements of this contract. The location and listing of the service data manuals, by name, and/or the manuals themselves shall be provided to the CO upon request.

Insurance Worker compensation and employer's liability. The Contractor and any subcontractor covered under this contract are required to comply with applicable Federal and State Workers' Compensation and occupational disease statutes. General Liability. The Contractor and any subcontractor covered under this contract are required to have bodily injury liability insurance coverage written on the comprehensive form of policy of at least $500,000 per occurrence. Property Damage Liability. The Contractor and any subcontractor covered under this contract are to have property damage liability insurance coverage of at least $500,000. The Contractor shall provide proof of liability insurance within five (5) days after contract award.

Smoking Policy Smoking is prohibited inside all buildings except in designated areas.

Pricing Submittal The annual pricing of the contract should be itemized by the bidders to reflect a cost per unit PM per equipment item covered by contract.

Vendor Requirements The Contractor must employ mechanics and technicians that are trained in the applicable codes, standards, and manufacturer requirements for maintenance and repair of the Trane and McQuay equipment covered by this contract. The Contractor must have at least 5 years' experience satisfactorily performing such maintenance on comparable units, equipment, or systems. The Contractor must have access to OEM (original equipment manufacturer)-manufactured parts and materials required for performance of this work. The Contractor must have sufficient supplies, tools, and equipment to perform all requirements of this contract. The NAICS code for this requirement is 238220.

Sole-Source Rationale Engineering identifies Trane U.S. Inc. as the necessary single source for the specified, integrated manufacturer-supported BAS service requirement. The existing campus Tracer/SC+ and Ensemble architecture is an established Government investment; this acquisition requires servicing that platform, including manufacturer-specific software updates, programming/configuration support, controller firmware, SC+ license management, Ensemble updates and subscription support, backups, and functional controls verification. These requirements are not met merely by furnishing generic BACnet connectivity, routine instrument calibration, or a different manufacturer's controls platform. The Trane Ensemble system is proprietary, as is the service of its programming, software, and replacement components, which relies on Trane-specific access. That rationale continues to be applicable to the installed Trane controls architecture; the current acquisition adds expressly identified software subscriptions, supported updates, and a larger inventory of Trane Tracer SC/SC+ controllers. The Government is not acquiring a substitute BAS or soliciting another controls manufacturer's equipment. On September 25, 2026, the VA awarded Trane U.S. Inc. Order 36C24126F0113 for the Buildings 1 and 2 LON-to-BACnet controls upgrade. This separately awarded work replaces legacy field-level controls with Trane Tracer S500 controllers and related components, integrates them into the existing Trane SC+ architecture, and includes programming, graphics, functional verification, turnover, and one-year warranty obligations. This ongoing integration increases the importance of consistent supported software, configuration, and diagnostics in the associated maintenance requirement. The scope of the maintenance order is distinct from the modernization contract: it preserves recurring operations and installed-platform support, while the modernization contract covers conversion, commissioning, and warranty work. Maintaining manufacturer accountability for the installed server-connected Tracer/SC+ platform, current software entitlements, and new field-controller integration avoids divided responsibility during configuration changes, troubleshooting, and restoration of critical clinical mechanical controls. Engineering's sole-source technical recommendation is therefore Trane U.S. Inc. for the full manufacturer-supported service requirement, based on the documented Trane-specific functions and Trane's demonstrated delivery of the current service and modernization work. The prior award and OEM status are supporting facts.

Notice of Intent This notice of intent is not a solicitation nor is it a request for proposal. However, interested parties that believe they can satisfy the requirement must clearly identify their capability to do so in writing by November 25, 2026, at 12 p.m. EST. Responses should be sent to Issa Shawki at issa.shawki@va.gov. Information submitted in response to this notice will be used solely to determine whether competitive procedures could be used for this acquisition. A determination not to open this requirement to competition based upon responses to this notice is solely within the discretion of the Government.