The Department of Veterans Affairs is seeking qualified firms for independent fire protection and life safety review services for a boiler replacement project at the Colmery-O’Neil VA Medical Center. - Government buyer: Department of Veterans Affairs, Network Contracting Office 15 (NCO 15), NCO 15 Contracting Office; buyer contact named: James Petrik. - Project: Replace Boilers Fire Life Safety, Project No. 589A5-25-150, at the Colmery-O’Neil VA Medical Center in Topeka, Kansas. - Requested service: Independent fire protection and life safety code review of the 90% design submission. No products, quantities, part numbers, OEMs, or vendors are specified. - Deliverables and requirements: Provide an editable Excel and PDF review report with applicable code and VA references; include secondary review by a qualified Fire Protection Engineer and follow-up technical support. Reports are due within 10 business days after receipt of each submission package, and potential issues affecting completion must be raised within three business days. - Personnel and platform: Fire Protection Engineers must meet stated education, professional licensure, and experience requirements. The contractor must provide a VA-accessible, Microsoft-compatible document collaboration platform. - Eligibility and selection: The notice seeks qualifications from Service-Disabled Veteran-Owned Small Business firms through SF 330 submissions. It is a presolicitation announcement, not a request for proposals or an award.

Description

Presolicitation Notice Page 1 of Presolicitation Notice*=Required Field

Pre-Solicitation Notice: Request for Engineering Services Solicitation: 36C25527R0017, Fire Protection and Life Safety Code Review This acquisition pertains to the engineering services to review the design, construction documents and construction period services per supplement B for project 589A5-25-150 Replace Boilers Fire Life Safety (FLS). The Architect and Engineering contract has been awarded for this project and is currently at the 90% design submission stage.

CONTRACT AND TASK ORDER INFORMATION This A/E Services requirement is being procured in accordance with the Brooks Act (Public Law (PL0582) and implemented in accordance with the Federal Acquisition Regulation (FAR) Subpart 36. Firms will be selected based on demonstrated competence and qualifications for the required work. This procurement is restricted to Service-Disabled Veteran Owned Small Business (SDVOSB) firms. This requirement is being procured in accordance with the VAAR Subpart 836.6 as implemented in FAR Subpart 36.6. This is not a Request for Proposal, and an award will not be made with this announcement. This announcement is a request for SF 330s from qualified contractors that meet the professional requirements. The selection criteria for this acquisition will be in accordance with FAR 36.602-1 and are listed below in descending order of importance. The completed SF 330 will be evaluated by the Colmery-O Niel VA Medical Center VAMC, Topeka, Ks Evaluation Board in accordance with FAR 36.602-3 and the selection report shall serve as the final selection list, which will be provided directly to the Contracting Officer. The Government will not pay nor reimburse any costs associated with responding to this request. The Government is under no obligation to award a contract as a result of this announcement. Award of any resultant contract is contingent upon the availability of funds. No solicitation document is available and no other information pertaining to project scope, etc. is available at this time. Any request for assistance with submission or other procedural matters shall be submitted via email only to james.petrikva.gov. Personal visits to discuss this announcement will not be allowed. The NAICS Code for this procurement is 541330 Engineering Services and small business size standard of $25.5M. Award of a Firm Fixed Price contract is anticipated. The anticipated time for completion of design is approximately 180 calendar days including time for VA reviews. It is not anticipated that this assessment will be tied to a design project. Construction period services are not required for this procurement.

The NAICS Code for this procurement is 541330, Engineering Services and the small business size standard of 25.5 Million. Award of a Stand Alone Firm Fixed Price contract.

DATABASE REGISTRATION INFORMATION:Apparent successful offeror as service-disabled veteran owned small business must be incompliance with VAAR 852.219-73 and must be certified in the SBA certification database at https://veterans.certify.sba.gov. SYSTEM FOR AWARD MANAGEMENT (SAM.GOV):Federal Acquisition Registrations require that federal contractors register in the System for Award Management (SAM.GOV) database at https://sam.gov/content/ and enter all mandatory information into the system. Offerors are encouraged to ensure that they are registered in SAM.GOV prior to submitting their qualifications package. THE EXCLUDED PARTIES LIST SYSTEM (EPLS):To ensure that the individuals providing services under the contract have not engaged in fraud or abuse regarding Sections 1128 and1128A of the Social Security Act regarding federal health care programs, the contractor is required to check the Excluded Parties List System (EPLS) located at https://sam.gov/content/ for each person providing services under this contract/task order. Further the contractor is required to certify that all persons listed in the qualifications package have been compared against the EPLS list and are NOT listed. During the performance of this contract the Contractor is prohibited from using any individual or business listed on the List of Excluded Individuals/Entities. E-VERIFY SYSTEM:Companies awarded a contract with the federal government shall be required to enroll in E-Verify within 30 days of the contract award date. They shall also need to begin using the E-Verify system to confirm that all their new hires and their employees directly working on federal contracts are authorized to legally work in the United States. E-Verify is an Internet-based system that allows an employer, using information reported on an employee's Form I-9, to determine the eligibility of that employee to work in the United States. There is no charge to employers to use E-Verify. (FAR 52.222-54) A/E firms are required to respond if interested by submitting one (1) completed Standard Form 330 qualification package Parts I and II to include all consultants (form available on-line at: https://www.gsa.gov/system/files/SF330-21_Part_1.pdf and SF330-21_Part_2.pdf (gsa.gov)). Must include in Part I Section H an organizational chart of the firm (excludes consultants) and a design quality management plan. Submission information incorporated by reference is not allowed. All submissions shall be made electronically. Completed package shall be delivered electronically on or before 12/04/2026 at 2:00PM Central Standard Time to the NCO 15 Contracting Office, to the Contracting Officer at james.petrik@va.gov.

The SF330s of interested firms will be reviewed. Any additional or supplemental information to be submitted must be in pdf format, not to exceed 10 MB and emailed. Email subject line shall clearly identify Solicitation number: 36C25527R0017 and project name, REPLACE BOILERS FLS, Project No.657A5-25-150.

PROJECT INFORMATION FIRE PROTECTION ENGINEERING AND LIFE SAFETY CODE REVIEW SERVICES

I. SCOPE OF WORK The Department of Veterans Affairs is seeking an independent third-party fire protection and life safety code review for a delegated construction project as required by Veteran Health Administration (VHA) Directive 7712 Fire Protection Code Reviews of Delegated Construction Projects. The review must be performed by qualified Fire Protection Engineers (FPEs) who meet the qualifications and experience requirements outlined in Section IV, Qualifications of this PWS. The contractor shall provide all personnel, equipment, supplies, facilities, tools, materials, supervision, and other items necessary to meet the requirements.

II. DESCRIPTION OF TASKS

A. General Requirements All written deliverables shall be phrased in layperson's language. Statistical and other technical terminology shall not be used without providing a glossary of terms. The COR and/or CO may require the contractor to meet virtually with the CO, contract administrator, and other government personnel as deemed necessary. The contractor may request a virtual meeting with the COR and/or CO when deemed necessary. The contractor shall provide, via email, minutes of all government-contractor meetings. The contractor shall provide these draft minutes within two business days after completion of the meeting. The government representative will review draft minutes; make edits as appropriate and return to the contractor. Contractor shall have one business day after receipt to finalize minutes and return to the government. The contractor shall ensure contract employees maintain open and professional communication with the staff at the VA facilities. Complaints validated by the COR or VA staff will be reported in writing to the CO for action. If the contractor fails to correct validated complaints raised by the COR and CO to the satisfaction of the COR, it will be considered a failure in performance.

B. The Platform The vendor shall provide a Microsoft compatible web-based collaborative platform accessible to VA staff. The purpose is to provide a platform where the design documents can be uploaded by the VA for contractor review. The platform must be compatible with VA Microsoft Office programs and allow for the transfer of large files from behind the VA Intranet fire wall to the platform. The VA email system will not support this function. The construction project documents to be reviewed include drawings, specifications and other documents.

C. Project Fire Protection and Life Safety (FLS) Review Fire protection and life safety review[s] are to be provided at the 90% design submission level. The VA COR or designated representative will submit a fire protection and life safety (FLS) review request and a set of associated project documents for contractor review when design documents are available. Design review documents could include narratives, specifications, drawings, Requests for Information (RFIs), or other documents. The documents will be provided in electronic format to the vendor via email. See VA Program Guide PG-18-15 for typical A/E Submittal requirements that would be reviewed. The written project review report, referred to as the FLS Review Report, must be developed and submitted by the contractor in editable Microsoft Excel format. Both an Excel file and PDF of the review must be submitted to the VA for each review request. A sample FLS Review Report form must be submitted by the contractor and approved by the COR prior to being used for reviews. The written FLS Review Report must provide both suggested mandatory comments (based on code, standard, or VA requirements) and advisory comments (recommendations) regarding fire protection and life safety. All comments must include a specific section reference to the corresponding NFPA code, standard, VA Fire Protection Design Manual reference, and/or other relevant VA reference material. Any comments that are advisory (recommendations, not mandatory) must be identified as such in the FLS Review Report. The contractor shall ensure that the written project FLS Review Report is reviewed by a secondary qualified Fire Protection Engineer to ensure accuracy; the report must include the names of both the primary and secondary reviewers. The contractor must return the completed report via email to the COR or representative who submitted the request within 10 business days of the contractor's receipt of the submittal package. Where the contractor has performed a previous review of a project and the project is submitted again for review at a later stage of design, the VA COR or facility representative will document the resolutions to the previous comments made by the contractor and will submit that documentation back to the contractor prior to the contractor's subsequent review of the new design submission. Design reviews must include a review of the following items, at minimum: Classification of Occupancy (this must be determined before a review can be started) Minimum Construction Requirements (and separation) Means of Egress Components (stairs, ramps, doors, door hardware, etc.) Capacity (Clear Widths) Number of Means of Egress Arrangement Travel Distance (including but not limited to exits, within suites, to smoke barriers, etc.) Discharge from Exit Illumination Emergency Lighting Marking Exit Signs Suites Protection Vertical Openings Hazardous Areas Detection/Alarm Systems Suppression / Extinguishment (Sprinklers, extinguishers, clean agent, kitchen, etc.) Corridors (Separation, etc.) Subdivision of Building Spaces (Smoke barriers, occupancy separations, etc.) Building Services Utilities Heating, Ventilation, and Air Conditioning Elevators Chutes Design Specifications, if provided Narrative, if provided Confirmation that a fire protection engineer on the A/E's design team has performed fire alarm, fire suppression, and life safety design for the project. Follow-up technical support shall be provided by the contractor as needed to all facilities to respond to questions regarding the project design review comments. The contractor must inform the VA submitter of potential problems that could interfere with successful completion of the project review within a maximum of three business days after receiving the FLS review request and associated design documents.

III. ACCEPTANCE OR REJECTION OF DELIVERABLES Reports / documents will be accepted by the VA when all discrepancies, errors or other deficiencies identified in writing by the COR, designee or government representative have been corrected. Electronic copies shall be delivered via email to the VA submitter. The contractor shall use best commercial practice for formatting reports and documents. If the government representative finds that the report/document contains spelling errors, grammatical errors, improper format, or otherwise does not conform to the requirements stated in this SOW, the document may be immediately rejected without further review and returned to the contractor for correction and resubmission.

IV. QUALIFICATIONS - FIRE PROTECTION ENGINEER The Fire Protection Engineer (FPE) who performs the plan review and authors the FLS Review Report must have the following qualifications: Must have obtained an ABET-accredited bachelor's degree in fire protection engineering or a master's degree or other advanced degree in fire protection engineering ("fire safety" or similar degrees are not acceptable). Must have passed the principles and practices (PE) examination in fire protection engineering. Must maintain a current United States-based professional engineering license in fire protection engineering. It is understood that some states do not issue dedicated PE licenses in Fire Protection Engineering; in such cases, an individual's state licensure must be predicated upon passing the PE examination in fire protection engineering. Five years of experience in application and interpretation of National Fire Protection Association (NFPA) Codes and Standards and the model building codes. Five years of experience in the design and review of fire suppression and fire alarm systems, including all the following: Automatic sprinkler and fire alarm system shop drawings. Automatic sprinkler system hydraulic calculations. Fire alarm system voltage drops and battery calculations. Clean agent systems. Standpipe systems. Five years of experience in the application and interpretation of NFPA codes and standards, including, but not limited to, NFPA 1, 3, 4, 10, 13, 14, 17A, 20, 24, 25, 30, 45, 72, 75, 80, 82, 90A, 96, 99, 101, 110, 220, 241 and 2001. Five years of experience in the design of health care facilities on projects of similar relevance and complexity. Five years of experience in acceptance testing fire protection systems. Five years of experience providing fire protection and life safety plan review services for complex health care occupancies (occupancies containing NFPA 101 suites, high-rise buildings, horizontal exits, separated and mixed occupancies, etc.).

Substitution of Personnel All FPEs working on this contract must have their resumes reviewed and approved by the COR and the Contracting Officer. New personnel shall not commence work until all necessary security requirements have been fulfilled, and resumes provided and accepted. The COR or designee will evaluate such requests and promptly notify the contractor of approval or disapproval in writing.

VI. GOVERNMENT AND CONTRACTOR RESPONSIBILITIES The VA COR or government designee will provide the contractor with copies of documents that the VA is legally required to provide. The contractor shall request other VA documentation deemed pertinent to the work directly from the COR, government designee or facility representative. The contractor is expected to use common knowledge and resourcefulness in securing all other reference materials, standard industry publications, and related materials that are pertinent to the work without violating any applicable copyright laws. The most current versions of such documents will be used for all referenced documents. If a version cited in this SOW is updated during the period of performance of this contract, then the most recent / updated version will be applied. The contractor shall maintain communications with the VA COR, government designee or facility representative as needed to complete the scope of this task. The government will be available for communication (calls, email, etc.) as reasonably needed to complete the scope of this task, subject to COR availability. The contractor is not required to perform services on the following federal holidays set by law (USC Title 5 Section 6103): New Year's Day Martin Luther King's Birthday Washington's Birthday Memorial Day Juneteenth Independence Day Independence Day Labor Day Columbus Day Veterans Day Thanksgiving Day Christmas Day

EVALUATION FACTORS Selection criteria are in accordance with Federal Acquisition Regulation (FAR) Part 36.202-4. Additional/supplemental information can be submitted to address all selection criteria provided in this pre-solicitation notice. Qualifications (SF330) of each interested firm for Project No. 589A5-25-150, will be reviewed and evaluated based on the evaluation criteria listed at section IV of the Statement of Work above.