Opportunity

New York State Contract Reporter #2140961

CUNY seeks a benchtop single-molecule mass photometry system and support

Posted

November 18, 2026

Respond By

December 10, 2026

Identifier

2140961

NAICS

334516, 423490

CUNY’s Advanced Science Research Center seeks a complete benchtop mass photometry system for label-free analysis of single molecules in native solution. - Buyer: City University of New York (CUNY), CUNY Graduate Center, Advanced Science Research Center (ASRC). - OEMs and vendors: No manufacturer, OEM, model, or vendor is named; compliant equivalent products may be proposed with supporting documentation. - Quantity: One benchtop single-molecule mass photometry system, including external control electronics, acquisition and analysis software, and a high-performance workstation. No part number is specified. - Performance: Measure 30 kDa to 5 MDa, with stated resolution benchmarks of 25 kDa at 66 kDa and 60 kDa at 660 kDa; precision of 2% or better and accuracy/error within ±5%. Support 100 pM–100 nM samples, use no more than 20 µL per measurement, provide sub-nanogram protein sensitivity, and acquire results in under five minutes per sample using a standard 60-second recording. - Hardware and software: Enclosed Class 3B 488 nm laser in a Class 1 laser-safe housing with interlocks; high-NA oil-immersion objective; high-speed CMOS detector with 12 nm effective pixel size; selectable fields of view and frame rates; continuous autofocus on the glass-water interface; active anti-vibration isolation; compact optical unit approximately 504 × 314 × 135 mm; and software for automated focus, live landing-event visualization, video capture, mass calibration, analysis, and exportable results. - Services: On-site installation, calibration verification, servicing, and user training in system operation and data analysis. - Term: One year. Specific start and end dates are not stated.

Description

CUNY’s Advanced Science Research Center seeks vendors to provide, install, and service a benchtop single-molecule mass photometry system, or an equivalent meeting the stated requirements. Specifications cover measurement range and accuracy, optical and detector components, software, workstation, and anti-vibration isolation. The scope also includes on-site installation, calibration verification, and user training. Vendors proposing an equivalent must submit a written statement and supporting documentation demonstrating compliance with each requirement.

View original listing