Opportunity

SAM #36C26127Q0169

VA Palo Alto fire-suppression maintenance and kitchen exhaust cleaning services

Buyer

VA Network Contracting Office 21

Posted

November 17, 2026

Respond By

November 30, 2026

Identifier

36C26127Q0169

NAICS

811310

The Department of Veterans Affairs’ VA Palo Alto Health Care System is seeking qualified firms to maintain fire-suppression systems and clean and certify kitchen exhaust equipment across three facilities. - Buyer: Department of Veterans Affairs, VA Palo Alto Health Care System; Network Contracting Office 21. Contracting Officer: Kulvinder Brar. - Scope: Annual and semi-annual inspection, testing, maintenance, cleaning, and certification of fire-suppression systems, grease hoods, ducts, exhaust fans, and chemical hazardous-material storage sheds at Palo Alto, Menlo Park, and Livermore. - OEMs named: Ansul, Pyro Chem, Kidde, FIKE, Gaylord, and Gemini. IKECA is also named as a certification body, not an equipment OEM. - Equipment inventory: Gaylord hoods (RG-BDL-48, 796-102918, RG-BDL-54, 796-102899) and control cabinets (QUA-1.50-16, QUA-1.25-6); Gemini hood (PCL350); Pyro Chem systems (PCI-35, PCI-15, PCI); Ansul system (I-101); Kidde system (IND-21); and FIKE system (Cheetah-XI). Inventory quantities are not specified. - Service quantities listed: Palo Alto: 2 main-kitchen hoods and 3 canteen hoods; fire-control systems for 5 hoods; 3 chemical storage sheds. Menlo Park: 1 main-kitchen hood, 1 shed fire-control system, and 1 building fire-control system. Livermore: 2 chemical storage sheds. - Key qualifications and standards: California C-16 contractor license; manufacturer certification or documented equivalent system training; IKECA certification or equivalent qualifications for grease-hood personnel; and compliance with applicable NFPA standards, including NFPA 17A, 96, 10, and 72. - Notable site requirements: Work is scheduled after hours at specified buildings; certain tasks require breaker-box or facility keys, coordination for alarm deactivation, and access arrangements for hazardous-material storage areas. - Opportunity status: Sources-sought market research; no specific equipment inventory quantities or contract performance dates are provided.

Description

THIS IS A SOURCES SOUGHT ANNOUNCEMENT ONLY.
No Solicitation is currently available. All information contained in this Sources Sought Announcement is preliminary, as well as subject to modification, and is in no way binding on the Government. The Government will not pay for any information submitted in response to this request. The information requested will be used solely within the Department of Veterans Affairs to facilitate decision making and will not be disclosed outside of the Government. The determination of a procurement strategy, based upon the comments submitted in response to this Sources Sought Announcement, is solely within the discretion of the Government. Potential Offerors must be registered in the System for Award Management (SAM) to be eligible for an award (See Internet Site https://www.sam.gov/portal/public/SAM/). Potential Offerors must also have a current Online Representations and Certification Application on file with SAM. The applicable North American Industry Classification System (NAICS) Code is 811310, Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance and size standard is $12.5 million. NOTE: Please ensure that System For Award Management (SAM) indicates this NAICS code if you are interested in the requirement. Before responding please carefully read and consider the following: As this is a service acquisition, the Small Business Administration and the Federal Acquisition Regulation have a Limitations on Subcontracting requirement. For all small businesses, to include SDVOSB and VOSB, it will not pay more than 50 percent of the amount paid by the Government for contract performance to subcontractors that are not similarly situated entities. Any work that a similarly situated entity further subcontracts will count towards the prime contractor's 50 percent subcontract amount that cannot be exceeded. When a contract includes both services and supplies, the 50 percent limitation shall apply only to the service portion of the contract. See FAR 52.219-14 and FAR 52.219-27 available in full text at https://www.acquisition.gov/far/html/52_217_221.html

Brief Description of Services

The VA Palo Alto Health Care System (VAPAHCS) has a requirement for Dry-type fire suppression system maintenance and testing of Grease hoods, exhaust fans and chemical Hazmat Sheds. The Government is seeking only qualified kitchen exhaust cleaning specialists who hold current certification through the International Kitchen Exhaust Cleaning Association (IKECA) or an equivalent recognized industry association. Vendors must provide documentation demonstrating compliance with applicable NFPA standards, including NFPA 72 and 96, and furnish all required qualifications, training records, and certifications for personnel performing kitchen exhaust and grease hood cleaning services.

General This is a non-personal services contract to provide Dry-Type Fire Suppression System services for the VA Palo Alto Health Care System (VAPAHCS). The Government shall not exercise any supervision or control over the contract service providers performing the services herein. Such contract service providers shall be accountable solely to the Contractor who, in turn is responsible to the Government.

Place of Performance:

Palo Alto Main Campus 3801 Miranda Ave. Palo Alto, CA 94304 Menlo Park Medical Center 795 Willow Rd. Menlo Park, CA 94025 Livermore Medical Center 4951 Arroyo Rd. Livermore, CA 94550

Contractor Qualifications:

Contractor shall possess a California C-16 contractor license and be certified by the system manufacturer to service and repair Ansul and related Automatic Fire Control Systems, or provide documentation of equivalent system training. Grease hood cleaning shall be performed by International Kitchen Exhaust Cleaning Association (IKECA)-certified or equivalent association Certified Exhaust Cleaning Specialists (CECS), or personnel who can document compliance with all applicable NFPA 72 and NFPA 96 grease hood cleaning qualification and certification requirements. The Government reserves the right to request and review such licenses, certifications, and supporting documentation at any time during the contract period.

Preventative Maintenance and Testing

Contractor shall provide all tools, materials, equipment, labor, and transportation to perform annual and semi-annual cleaning and fire protection services/ certification of the following grease hoods, exhaust fans, and chemical storage sheds at three divisions of the Veterans Administration Palo Alto Health Care System (VAPAHCS). All cleaning shall be done in accordance with NFPA 96 latest edition. All fire protection service/inspections and certifications shall be performed per NFPA 17A, 96, 10 and 72 latest editions.

Capability Statement

The Government requests that only firms seriously interested and truly capable should send their capability information to the Contracting Officer, Kulvinder Brar by email at: Kulvinder.brar@va.gov no later than 3:00 PM Pacific Time, November 30, 2026: (a) Business Size (Large/Small) (b) Business Socio-Economic Status (SDVOSB, WOSB, 8(a), HUBZone, etc.) (c) SAM record (www.sam.gov) (d) VIP record (SDVOSB/VOSB firms only) (https://www.vip.vetbiz.gov/) (e) DUNS number (f) Ability and experience in managing similar projects. Include general information and technical background describing your firm's experience on contracts requiring similar efforts to meet the program objectives. (g) List of Projects (Government and Commercial) that are similar in scope and size. (h) Anticipated Teaming Arrangements (if any) (i) GSA Contract Number if applicable. (j) Copies of certificates/licenses as identified above under Contractor Qualifications Interested parties shall not submit more than 10 single-sided, type-written pages using 12-point font or larger. Published literature may be any number of pages. The Government will use this information when determining its business type decision.      *Failure to provide the information requested above (items (a) (j)) will be considered non-responsive and will not be considered a viable source.

DISCLAIMER This Sources Sought notice is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this request that is marked proprietary will be handled accordingly. The Government will not compensate an offeror for providing information in response to this sources sought. Furthermore, the Government reserves the right to cancel this requirement at its discretion. This is simply a sources sought notice.     