Opportunity

Utah Public Procurement Place U3P #CS27017-Stage II

Weber State University Student Services Building Phase II Remodel and Hybrid VRF Upgrade

Posted

November 16, 2026

Respond By

December 01, 2026

Identifier

CS27017-Stage II

NAICS

236220, 238220, 238210, 238290

Utah DFCM is seeking construction bids for the Phase II remodel and mechanical-system upgrade at Weber State University’s Student Services Building in Ogden. - Buyer and project - State of Utah, Department of Administrative Services, Division of Facilities Construction and Management (DFCM); Weber State University is the project user. - Work includes selective remodeling and mechanical, electrical, plumbing, structural, architectural, fire-protection, and fire-alarm work. - The construction estimate is $5.4 million; substantial completion is required within the project’s specified deadline. - OEMs and named firms - OEMs: Mitsubishi Electric, Swegon, Bell & Gossett, Rheem, Elkay, Woodford, Kohler, Hilti, Ardex, Pecora Corporation, 3M, Häfele, and Johnson Controls (Metasys controls). - GSBS Architects and ARW Engineers are identified in the project documents as design/engineering firms, not bidders or awarded contractors. - Key equipment and quantities - Mitsubishi City Multi water-source heat-recovery units: 11, model PQRY-P120; branch controllers: 15, models CMB-WP1016/CMB-WP108. These are owner-furnished and contractor-installed. - Mitsubishi split-system outdoor units: 2, PUY-AK18NL; matching indoor units: 2, PKA-AL18NL. - Swegon energy recovery ventilator: 1, RX 040; Bell & Gossett chilled-water pumps: 2, E1510-3EB; Rheem hybrid heat-pump water heaters: 2, 80-gallon units. - Additional scheduled equipment includes one B&G Ecocirc+ N 20-18F recirculation pump, one Elkay LZSTL8WSLK drinking fountain/bottle filler, one Woodford 24 hose bibb, and one Kohler K-3894 sink. - Specified finish and construction products include Ardex V 1200 underlayment, Pecora AIS-919 and AC-20 FTR acoustical sealants, Hilti Speed Plug/CP 777 or equal, 3M FASARA decorative film or equal, and Häfele H2135 pulls or equal. Structural calculations also reference a Hilti KWIK HUS-EZ anchor, item 418072; no purchase quantity is stated. - Notable requirements - Coordinate work in an occupied building and protect, remove, relocate, and reinstall designated furniture and owner equipment. - Install, connect, start up, test, balance, and commission building systems; provide a follow-up Metasys controls demonstration/training and continuous commissioning during the one-year warranty period. - The project specifications include a 75% construction-waste diversion target and contingency allowances of $50,000 for furniture removal/reinstallation and $10,000 for mechanical, electrical, and plumbing work.

Description

This is Stage II: Invitation to Bid in a multistage selection process for construction services at Weber State University’s Student Services Building in Ogden, Utah. The work is selective remodeling and an MEP upgrade to a Hybrid VRF system. Only contractors shortlisted during Stage I are invited to bid, and the stated construction cost estimate is $5,400,000.00. Bids and a 5% bid bond are due through U3P by December 1, 2026, at 3:00 PM MST.

View original listing