Opportunity
SAM #PANRSA-27-P0000-044177
Army market research for portable supplementary oxygen systems for MV-75 Cheyenne aircrew
Buyer
W6QK ACC-RSA
Posted
November 16, 2026
Respond By
December 16, 2026
Identifier
PANRSA-27-P0000-044177
NAICS
336413
The U.S. Army is gathering information on portable supplementary oxygen systems for MV-75 Cheyenne aircrew. - Government buyer: U.S. Department of Defense, Department of the Army, through Army Contracting Command–Redstone Arsenal (ACC-RSA), W6QK ACC-RSA. - Requested solution: Portable, roll-on/roll-off (RORO) supplementary oxygen system, preferably self-generating and not primarily dependent on stored oxygen cylinders or fixed-base generation and refill infrastructure. - Aircrew and operating need: Support two pilots and one nonrated crewmember for approximately seven hours at pressure altitudes up to 18,000 feet; identify any stored-oxygen reserve requirements. - Installation and usability: Minimize aircraft modifications and preferably fit within about 2.5 cubic feet (nominally 0.8 feet wide, 1.3 feet deep, and 2.3 feet high). Do not obstruct crew movement, emergency egress, or access to weapons and survival equipment. - Performance considerations: Address breathing flow, mask pressure, work of breathing, oxygen concentration, gas temperature, and contaminant control. Potentially relevant standards and criteria include MIL-STD-3050, MIL-PRF-27210, Army Military Airworthiness Certification Criteria, and applicable military aircraft requirements. - OEMs and vendors: No manufacturers, vendors, product models, part numbers, or line-item quantities are identified in the provided information. - Value and line items: No contract value or priced product/service line items are provided; this is an information request.
Description
The Government is seeking information on portable, RORO supplementary oxygen system solutions that may support MV-75 aircrew during extended-duration, high-altitude self-deployment operations. The Government is interested in self-generating approaches that can be installed and removed with minimal aircraft impact and without primary reliance on fixed-base oxygen-generation or refill infrastructure.
The Government is particularly interested in systems that: • Support a minimum of two pilots and one nonrated crewmember for approximately seven hours at pressure altitudes up to 18,000 feet. • Generate, distribute, and deliver or otherwise provide breathing oxygen without primary reliance on stored oxygen cylinders. Respondents should identify any required stored-oxygen reserve. • Can be installed without significant permanent aircraft modification or extensive changes to aircraft systems. • Fit within the currently allocated installation envelope of approximately 2.5 cubic feet, with nominal dimensions of 0.8 feet wide, 1.3 feet deep, and 2.3 feet high. Solutions exceeding this preferred envelope may be considered if necessary to meet the operational need. • Address applicable physiological performance considerations, including breathing flow, mask pressure, work of breathing, oxygen concentration, gas temperature, and contaminant control. The Government anticipates considering applicable portions of MIL-STD-3050 and/or MIL-PRF-27210, the Army Military Airworthiness Certification Criteria (AMACC), and guiding miliary aircraft requirements as appropriate. • Do not impede aircrew movement, emergency egress, or access to individual weapons and required survival equipment.
See Attachment for full requirements and submission instructions.