Opportunity

SAM #N40085-26-RFPRFQ-NEW-LONDON-ROICC-0049

Building 434 EPDM Roof Replacement at Naval Submarine Base New London

Buyer

Naval Facilities Engineering Systems Command Mid-Atlantic

Posted

November 02, 2026

Respond By

December 21, 2026

Identifier

N40085-26-RFPRFQ-NEW-LONDON-ROICC-0049

NAICS

238160, 238190, 236220, 238290

The U.S. Navy is soliciting roof replacement work at Naval Submarine Base New London in Groton, Connecticut. - Government buyer: Department of the Navy; NAVFAC Mid-Atlantic; Public Works Department, Facilities Engineering & Acquisition Division, Naval Submarine Base New London. The attachment also identifies PWD FEAD New London and NAVFAC Mid-Atlantic New London ROICC. Rebecca Spaulding is named in the RFP. - Primary scope: Remove and replace the existing roof system on Building 434, including related work needed for a complete, functional roof. The RFP states that Building 430 is excluded. - Roof system and related work: EPDM membrane roofing, insulation, vapor barrier, cover board, flashing, metal coping/parapet caps, roof drains and roof-leader repairs, sealant, and lightning-protection modifications. Retain and reinstall specified existing equipment, including the exhaust fan, roof hatch, solar panel, and lightning-protection equipment. - Hazardous materials: Required controlled removal, handling, and compliant disposal of asbestos-containing caulk, PCB-containing caulk, lead-painted roof hatches, and lead-soldered roof drains. The specifications identify approximately 64 and 70 linear feet of asbestos-containing caulk at Building 434, and PCB-containing caulk quantities of 2,320 linear feet of perimeter flashing and 20 linear feet of vent-boot caulk per building; they also identify eight hatches and 56 roof drains across Buildings 430 and 434. - Option discrepancy: The specifications describe a Building 430 roof replacement as an option, with an exercise window and schedule extension; however, the RFP says Building 430 is excluded. Confirm the controlling scope before treating Building 430 work as included. - Requirements: Improve insulation to current energy-code levels and perform construction while buildings remain occupied. - OEMs and vendors: No roofing manufacturer, OEM, or product vendor is named. No product part numbers are provided.

Description

The scope of this project is the removal and rplacement of the existing roof systems for Building 434 at the Naval Base New London located in Groton, CT. The work includes associated incidental construction necessary to provide a complete and functional roofing system.

ONLY THOSE CONTRACTOR LISTED BELOW ARE AUTHORIZED TO BID

 Doyon Management Services, LLC

Armitage SAI JV

Black Horse Construction Group

CCI Facility Support Services, LLC

View original listing