Opportunity

SAM #36C25627Q0085

VA switchgear and automatic transfer switch investigation and repair

Buyer

Vancouver VA Medical Center

Posted

November 02, 2026

Respond By

November 18, 2026

Identifier

36C25627Q0085

NAICS

811310, 238210

The Department of Veterans Affairs is seeking a one-time investigation and repair of critical switchgear and automatic transfer switch equipment at the G.V. Sonny Montgomery VA Medical Center. - Government buyer: Department of Veterans Affairs, Network Contracting Office 16. - Equipment manufacturers named: GE / GE Multilin, ABB, and ASCO; generator integration may involve a Caterpillar (CAT) dealer. - Systems and components: GE main switchgear and GE Multilin F-60, G-30, MIF II, and UR-series relays; ABB distribution switchgear and relays; and ASCO ATS-1 and ATS-2. No separate product quantities or part numbers are specified. - Requested service: One service engagement to inspect and troubleshoot equipment, document deficiencies, make required repairs or replacements, and conduct breaker and ATS functional testing. Work may include coils, control wiring, batteries, relays, and related components, plus generator/ATS integration and load-bank verification as needed. - Deliverables and notable requirements: Investigation and repair reports, an updated device condition log, and reliability recommendations; a one-year warranty is required. Work must be coordinated around scheduled outages and may require after-hours or weekend work. - Performance: One-time service with an approximately two-month performance window.

Description

This is a Request for Quote (RFQ). The Government anticipates awarding a firm-fixed price contract resulting from this solicitation. This RFQ is set aside for Service-Disabled Veteran Owned Small Business (SDVOSB). All respondents must have an active registration in the System for Award Management (SAM) at www.sam.gov and certified by the SBA in Small Business Search (SBS). Interested SDVOSB s must be listed to receive contract awards. Department of Veterans Affairs, Network Contracting Office 16, is soliciting offers for Switchgear (Automatic Transfer Switch (ATS) Investigation and Repair. The service will be provided to (GVSMVAMC) G.V. Sonny Montgomery VA Medical Center in Jackson MS, in accordance with the Statement of Work (SOW). Site Visit: Date/Time Location POC Tuesday November 10th from 9:00am to 1:00pm. G. V. (Sonny) Montgomery VA Medical Center 1500 E Woodrow Wilson Drive Jackson, MS 39216

Willard Bill Rushing Facility Operations Supervisor Cell: 601-559-7104 Willard.Rushing@va.gov

TECHNICAL QUESTIONS: All questions shall be received by Thursday November 12, 2026, at 4:00 P.M. CST. All questions submitted for this solicitation shall me electronically sent to the following email address: Vanessaann.Williams@va.gov. Please title email with the Solicitation Number, Technical Questions . Questions shall clearly identify which part of the solicitation. Questions received after the date stated may be addressed at the discretion of the Contracting Officer. Answers to questions will be addressed via an amendment to the solicitation posted to www.sams.gov. OFFER INSTRUCTIONS: 1. All offers are due NLT Wednesday, November 18, 2026, at 4:00 P.M. CST via e-mail only to Vanessaann.Williams@va.gov. Quotes shall be received on or before the date and time specified in Block 8 of the Standard Form (SF) 1449. Please title email with Solicitation Number, Proposal Submission, Vendor Name .

  1. Offeror must complete and return the signed SF 1449, blocks 30a, 30b, and 30c. By signing the Standard Form (SF) 1449/Solicitation, the contractor attests acknowledgement and understanding of all solicitation requirements.

  2. If applicable, must acknowledge receipt of all solicitation amendments by the offer due time/date specified, if applicable, by (a) Returning a signed copy of each amendment or (b) Acknowledging receipt of amendment on each copy of the quote or (c) By separate electronic communication which includes a reference to the solicitation and amendment numbers.

  3. Offeror must submit the Price/Cost Schedule with unit prices rounded to the nearest hundredth. Please ensure unit price and total amounts are correct. Offeror agrees to hold the price in its offer firm for 60 calendar days from the date specified for receipt of offers.

  4. Offeror must complete, sign, and return VAAR Clause 852.219-75 VA NOTICE OF LIMITATIONS ON SUBCONTRACTING CERTIFICATE OF COMPLIANCE FOR SERVICES AND CONSTRUCTION (JAN 2023) (DEVIATION).

  5. Offeror shall submit a Capability Statement that demonstrates their aptitude for working on these systems to include:

Investigation Tasks: Inspect and evaluate: GE Main switchgear (MV, LV sections as applicable) ABB Distribution switchgear sections ASCO ATS-1 and ATS-2 (including logic boards, transfer mechanism, control power circuits) Identify voltage ratings of trip and close coils. Rack breakers out for physical inspection. Perform mechanical integrity inspection (linkages, springs, shutters, rails). Evaluate relay configuration: GE Multilin F-60, G-30, MIF II, UR-series relays, ABB relays. Review protective relay event logs. Verify battery health for control relays. Inspect control wiring and MOC/TOC blocks. Document all deficiencies discovered. Repair Tasks: Replace trip coils/close coils where improper voltages or failures are found. Replace or repair MOC/TOC blocks. Replace relay control batteries. Repair/replace defective relays (G-30, Multilin series, if field-repairable, ABB). Correct wiring faults, loose lugs, damaged insulation. ATS logic troubleshooting and repair (ASCO control board testing, timing sequence validation, mechanical). Functional testing of each breaker after repair. Re-racking, lubrication, cleaning, and cabinet maintenance Generator/ATS Integration Testing (as needed) Support load-bank verification of generator response (coordination with CAT dealer). Remove/reconnect bias signals during generator tuning (if required). Deliverables Investigation Report identifying all deficiencies. Repair Completion Report summarizing corrective actions performed. Updated device condition log for the switchgear, ATS units, and relays. Recommendations for future reliability improvements.

It is the responsibility of the quoter to submit sufficient information to convey their technical capability in meeting the requirements of the Statement of Work. Failure to provide sufficient information will result in the quote being considered not technically acceptable.

  1. Provide a list of three (3) other concerns and/or Government agencies for which services similar in size and scope were rendered by the Offeror over the past three years. The list must include name of contact, organization, a valid email address, valid phone number, dollar value of project, and description of the project.