Opportunity

SAM #W9128F27RA045PN

Mather Fueling System Repairs and Modifications

Buyer

USACE Northwestern Division Endist Omaha

Posted

September 30, 2026

Respond By

October 14, 2026

Identifier

W9128F27RA045PN

NAICS

237120, 238990, 238210, 238220

The U.S. Army Corps of Engineers is seeking repairs and upgrades to the Mather, California, fueling system. - Government buyer: U.S. Army Corps of Engineers, Omaha District (W071 ENDIST Omaha). - OEM: Veeder Root — the named manufacturer for the automatic tank gauging system. - Requested work: Repair and modify the existing 12,000-gallon F-24 jet-fuel aboveground storage tank and surrounding fueling facilities. - Add a sampling/gauging hatch and mechanical gauge, recoat the tank exterior, replace collision barriers and alarms, and install a full-length tank catwalk. - Repair and re-slope the remote containment basin drainage pipe; replace asphalt and concrete pavement to improve drainage and reduce fuel-spill damage. - Replace the dispenser fuel monitor with a non-coalescing filter and hand-pumped water draw-off system. - Replace the POL building in kind and relocate the generator from inside the compartmentalized unit to outside. - Upgrade the automatic tank gauging system from a Veeder Root TLS-350 Plus to a Veeder Root TLS-450 Plus. - Quantities and part numbers: No separate product quantities or part numbers are provided; the 12,000-gallon tank is existing infrastructure. - Period of performance: Not specified in the provided information.

Description

This project involves modifying a 12,000 gallon jet fuel (F-24) horizontal aboveground storage tank and the surrounding fueling area. The tank work includes installing a sampling/gauging hatch on a tank manway, installing a clock type mechanical gauge on another manway, recoating the exterior of the tank, replacing collision barriers, adding a catwalk that extends the entirety of the tank, and replacing the audible and visual alarms. The remote containment basin drainage pipe shall be repaired and sloped positively to the drain inlet/manhole direction. The asphalt near the fueling facility shall be replaced to allow better storm water drainage. The refueler parking concrete shall also be replaced. The dispenser fuel monitor shall be replaced by a non-coalescing filter and a hand pumped water draw off system shall be installed as well. Near the truck offload area, some asphalt is getting replaced with concrete to prevent the degradation of the asphalt when fuel is spilled. The POL building is getting replaced in kind at the same location. The ATG system is getting upgraded from a Veeder Root TLS-350 Plus to a Veeder Root TLS-450 Plus. The generator located inside the compartmentalized unit is being moved outside. Additional Links:Department of Defense Procurement ToolboxPIEE Solicitation Module Link for W9128F27RA045PNRegistration Instructions for the PIEE Solicitation ModuleWeb Based Training for the PIEE Solicitation Module

View original listing