Opportunity
PIEE #W912HV26RA009
Bulk Fuel Storage Facility Construction at Yokota Air Base, Japan
Buyer
W2SN ENDIST JAPAN
Posted
August 13, 2026
Respond By
January 25, 2027
Identifier
W912HV26RA009
NAICS
237120, 237990
This opportunity from the U.S. Army Corps of Engineers, Japan District seeks construction services for a bulk fuel storage facility at Yokota Air Base, Japan. - Government Buyer: - U.S. Army Corps of Engineers, Japan District (W2SN ENDIST JAPAN) - Project Scope: - Construction of one 100,000-barrel cut-and-cover JP-8 storage tank - Reinforced concrete pump house with: - Four 600-gpm issue vertical turbine pumps - One 50-gpm water draw off vertical turbine pump - Product saver tank - Steel tank with concrete outer wall and rolling cover - Low slope concrete roof with built-up roofing for pump house - Advanced tank features: - High-level valve - Independent level alarms - Hardware for automatic tank gauging (ATG) system - Integration with existing filter separator building and control systems (including PLC and HMI modules) - Installation of piping, valves, vaults, and appurtenances - OEMs and Vendors: - No specific OEMs named for equipment; Primavera referenced in brand name justification (likely for project management software) - Notable Requirements: - Offerors must submit a Material Safety Data Sheet (MSDS) with proposals - Brand name justification for Primavera software - No administrative or procedural details included
Description
Project Title: DESC2103C - Bulk Fuel Storage Tanks Phase II. Project Description: Construct one 100,000-barrel cut-and-cover JP-8 storage tank. A pump house is to be provided on the top of the tank and contain four 600-gpm issue vertical turbine pumps and one 50-gpm water draw off vertical turbine pump. The new tank will include a high-level valve, independent level alarms, and the hardware necessary for the automatic tank gauging (ATG) system. The new tank includes piping, valves, vaults and appurtenances connecting to an existing filter separator building. The new control system of the new tank will be connected to the existing filter building that houses pump control Programmable Logic Controller (PLC) and Human Machine Interface (HMI), automatic tank gauge (ATG) reporting module capable of reporting inputs from all Eastside Fuel Facility tanks. A product saver tank is to be provided for the new bulk storage tank. The Pump House will be of reinforced concrete construction and site adapted to meet local conditions. The roof will be a low slope concrete roof with built-up roofing with overhangs over doorways. The tank is to be steel with concrete outer wall with a rolling cover for access to tank mounted equipment. The product recovery pump will return reclaimed fuel back through receipt filtration to the bulk storage tanks.