Opportunity
SAM #W50S8W26RA003
Structural and HVAC Upgrades at Building 16 Hangar, Cheyenne, WY
Buyer
Army National Guard USPFO
Posted
September 09, 2026
Respond By
September 19, 2026
Identifier
W50S8W26RA003
NAICS
236220, 238190, 238220, 238210, 238290
This opportunity is for structural and HVAC upgrades at Building 16 Hangar, Cheyenne, WY, managed by the Wyoming Air National Guard. - Government Buyer: - Air National Guard, 153d Airlift Wing, Wyoming Air National Guard (USPFO ACTIVITY WYANG 153 KO FOR WYANG) - Scope of Work: - Structural modification: Demolition and replacement of two structural bracing members with AWS certified welding and non-destructive testing (NDT) - Rerouting of electrical conduit and mechanical piping, including insulation and leak testing - Replacement of one hydronic coil for the Makeup Air Unit (MAU), meeting or exceeding original CFM/BTU specifications - Testing, adjusting, and balancing (TAB) of the HVAC system after coil installation - Products/Services Requested: - Structural bracing members (2 units) - Hydronic coil for MAU (1 unit) - Repair cross members (1 job) - Repair utilities conduit (1 job) - Remove/replace MAU coil (1 job) - Unique Requirements: - All work must comply with federal, state, and local codes, including Davis Bacon prevailing wages - One-year warranty on workmanship and materials from final acceptance - Non-destructive testing of welds by an independent agency - Comprehensive testing and balancing of HVAC system - Project is federally funded under Sustainment, Restoration, and Modernization funds - No specific OEMs, brands, or part numbers are provided; contractors must match or exceed original equipment specifications.
Description
This project modifies existing structural cross members within the Building 16 hangar to improve clearance and operational support. This modification requires the rerouting of adjacent electrical conduit and mechanical piping. Concurrently, the facility’s MAU hydronic coil, which has reached the end of its service life, will be replaced to ensure continued environmental control and energy efficiency.