Opportunity
SAM #M00681BackflowPreventers
Backflow Preventer Assemblies for Marine Corps Air Station Yuma
Buyer
Commanding General, MCIWEST
Posted
September 03, 2026
Respond By
September 09, 2026
Identifier
M00681BackflowPreventers
NAICS
332911, 423720
This procurement opportunity seeks contractors to supply backflow preventers for Marine Corps Air Station Yuma, managed by the Department of the Navy's Installation, Logistics and Environmental Department. - Government Buyer: - Department of the Navy, Marine Corps Air Station, Installation, Logistics and Environmental Department - OEMs and Vendors Mentioned: - Zurn-Wilkins - Apollo - Watts - Febco - Products/Services Requested: - Multiple backflow prevention assemblies for potable water systems - Specific models and part numbers include: - Wilkins 375XLRP (sizes 1/2", 3/4", 1", 1-1/2", 2", 4", 6") - Wilkins 975XLRP (sizes 1", 1-1/2", 2") - Apollo RPLF4A (1") - Febco 825YRP (2") - Febco 765PVB (2") - Watts 009RP (2-1/2", 3") - Watts 909RP (4") - Watts 957RP (4") - Wilkins 375ARP OSY Gate (4") - Watts 709DC (4") - Quantities: - Ranges from 1 to 9 units per model/size, with detailed breakdowns provided - Unique/Notable Requirements: - Equivalent devices from other nationally recognized manufacturers are acceptable if they meet or exceed specifications and certifications - Assemblies must comply with Arizona Department of Environmental Quality standards and relevant national certifications (e.g., ASSE, AWWA, NSF/ANSI, UL/FM) - Partial deliveries and multiple manufacturers are permitted - No additional certifications beyond manufacturer specifications required - Delivery required within 60 days after award - Minimum salient characteristics and specifications are referenced in attachments - Technical Features: - Lead-free, corrosion-resistant materials - Health hazard protection for potable water - Flood sensor and monitoring options for some models - Sizes range from 1/2" to 6" (with some specs up to 10") - Accessories include repair kits, thermal expansion tanks, and monitoring switches
Description
Market Research for Backflow Preventors The Regional Contracting Office MCI-West is conducting market research to identify contractors for providing Backflow Preventors to support Installation Marine Corps Air Station, Yuma, for a one-time buy of supplies. Please provide your total pricing for all items and quantities, to include unit prices, for budget estimates. The North American Industry Classification Standard (NAICS) code for this project is 332911 (Industrial Valve Manufacturing with a size standard of 750 Employees). NAICS code compliance verification will occur if/when proposals are submitted. Minimum Salient Characteristics: See attached draft Minimum Salient Characteristics and respective specification PDFs. Responses to Request for Information: Contractors are reminded that this is a REQUEST FOR INFORMATION and is NOT a request for proposal/bid/quote. Responses to this notice shall not constitute responses to solicitation. Responses to this notice are not considered offers and cannot be accepted by the Government to form a binding contract. This Request for Information is not to be construed as a commitment by the Government, nor will the Government pay for the information submitted in response. Respondents will not be notified of the results of any government assessments. It is requested that interested businesses submit to the contracting office a brief capabilities statement. The capabilities statement must clearly detail the firm's ability to perform all aspects of this notice and must include the following: a) Data Universal Numbering System (DUNS) number, Commercial and Government Entity (CAGE) code, and a statement regarding the socio-economic status of the company (Section 8(a) of the Small Business Act (8a) small business concern, certified Historically Underutilized Business Zone (HUBZone), Service-Disabled Veteran-Owned Small Business (SDVOSB) concern, etc.). b) Confirmation that your company can meet the certifications required in the Minimum Salient Characteristics, Proposed Units and Terms, and specification worksheet PDFs. c) Relevant Experience providing supplies identified in the DRAFT Minimum Salient Characteristics to include: experience in performing efforts of similar size and scope within the last three years. Please include a brief description of the project, contract number, and contract value. Proposals are not to be submitted at this time. This is a Request for Information only, NOT A REQUEST FOR PROPOSAL/BID/QUOTE. No questions will be answered. The information received will be utilized to assist in formulating the acquisition. Respondents will not be notified of the results of any government assessments. All responses will be treated as proprietary. Deadline for Submissions: 9 September 2026, 16:30PM (PDT). All submissions must be sent via electronic mail to: sabastian.dorsett@usmc.mil and allen.l.hayes@usmc.mil. Primary Point of Contact: Sgt Lake, Contract Specialist Regional Contracting Office MCI-WEST, Camp Pendleton, CA Email: sabastian.dorsett@usmc.mil Proposed Units and Terms: SIZE TYPE SPECS QUANTITY DIMENSIONS FACT SHEET 1/2" 375XLRP WILKINS Size 20mm; Dimensions 8-7/8" 225mm 2 A 3/4" 375XLRP WILKINS Size 20mm; Dimensions 8-7/8" 225mm 4 A 1" 375XLRP WILKINS Size 25mm; Dimensions 11-3/16" 284mm 4 A 1" RPLF4A APOLLO Size 1"; 14-5/8 2 B 1" 975XLRP WILKINS Size 25mm; Dimensions 13" 330mm 2 C 1-1/2" 375XLRP WILKINS Size 40mm; Dimensions 15-1/4", 387mm 2 A 1-1/2" 975XLRP WILKINS Size 40mm; Dimensions 17-3/8", 441mm 2 C 2" 375XLRP WILKINS Size 50mm; Dimensions 16", 406mm 9 A 2" 825YRP FEBCO Size 17-3/4" 2 D 2" 765PVB FEBCO Size 50mm 5 E 2" 975XLRP WILKINS Size 50mm; Dimensions 18-1/2" 470mm 1 C 2-1/2" 009RP WATTS Size 65mm; Dimensions 41-1/4" 1048mm 2 Series 009RP WATTS PDF 3" 009RP WATTS Size 34 1/4" 870mm;Dimension 18.5" 470mm 5 Series 009RP WATTS PDF 4" 909RP WATTS Size 100mm;Dimensions 551/8" 1400mm 3 F 4" 957RP WATTS Size 857mm 33 3/4";Dimension 30 1/8" 765 mm 5 Series 957RP WATTS PDF 4" 375ARP WILKINS OSY Gate Size 100mm; Dimensions 37-5/8" 956mm 5 G 4" 709DC WATTS Dimensions. 52-3/8" 1332mm 2 I 6" 375XLRP WILKINS OSY Gate Size 150 Dimensions 44-3/4" 1137mm 2 J Attached are the Excel and Adobe documents providing further information on this requirement. The items can be any brand that meets the minimum specifications provided. Questions regarding this requirement: Approved Equals: Will the Government consider equivalent backflow prevention devices from other nationally recognized manufacturers when the specified manufacturer or model is unavailable, provided the proposed device meets or exceeds the required specifications and applicable certifications?Answer: Yes. Partial Deliveries: Will the Government permit partial or staggered deliveries when some devices are immediately available while others have longer manufacturer lead times?Answer: Yes. Multiple Manufacturers: Can a vendor provide devices from multiple approved manufacturers to satisfy the requirement, or must all devices be supplied by the same manufacturer?Answer: Yes. Substitutions Due to Availability: If a listed model is discontinued, backordered, or unavailable within the required delivery period, what documentation will be required for the Government to approve an equivalent substitute?Answer: A list of the specifications on the equivalent substitute before moving forward. Delivery Location and Freight: Will the formal solicitation identify the exact delivery location, unloading requirements, delivery hours, and whether a loading dock or forklift will be available for larger assemblies?Answer: Yes. Required Certifications: Are there specific certifications or approvals required for each device, such as ASSE, USC-FCCCHR, NSF/ANSI, AWWA, or other applicable standards, beyond the manufacturer specifications provided?Answer: No. The Required Delivery Date is 60 days post award, or sooner. Please let me know if there are any questions regarding this market research. Please be aware this is not a request for quotes or proposals and is SOLELY for market research purposes.