Opportunity
SAM #140PS126B0010
Construction of North Unit Visitor Center at Badlands National Park
Buyer
National Park Service CONOPS Strategic
Posted
September 02, 2026
Respond By
October 15, 2026
Identifier
140PS126B0010
NAICS
236220
This opportunity is for the construction of the North Unit Visitor Center at Badlands National Park, South Dakota, managed by the Department of the Interior, National Park Service. - Government Buyer: - Department of the Interior, National Park Service, NPS ConOps Strategic Business Services Contracting Division - Scope of Work: - Construction of a new, one-story, 16,700–38,000 sq ft visitor center with utilities, site improvements, parking, and circulation - Includes demolition, concrete, metals, wood, thermal protection, openings, finishes, specialties, furnishings, fire suppression, plumbing, HVAC, electrical, communications, security, earthwork, and exterior improvements - Three option items: East Shade Structure, West Shade Structure, and Concrete Monument Sign at East Entry Drive - Notable OEMs and Products: - Plumbing: Kohler (water closets, lavatories), Sloan (flush valves), Bradley (lavatory fixtures), Halsey Taylor (water coolers), Speakman (emergency eyewash), JR Smith (floor sinks), Woodford (hose bibbs), Zurn (wall hydrants), In-Sink-Erator (garbage disposers), Leonard (tempering valves), Eemax (electric water heaters), Bradford White (gas water heaters) - HVAC/Mechanical: Ingersoll Rand (air compressors), Coxreels (hose reels), Champion (air filters), Torit Donaldson (dust collectors), Berko (baseboard heaters), Daikin (air handling units, cooling coils, condensing units) - Security/Technology: Hanwha and Axis (security cameras), Aruba (wireless access points) - Unique Requirements: - Compliance with 2024 building codes and standards - Coordination of multiple engineering disciplines - Detailed submittal and quality assurance requirements - Project magnitude estimated at $10M–$20M - Set aside 100% for small businesses under NAICS 236220 - Products/Services Requested (examples): - Wall hung water closets (Kohler Kingston K-84325) - ADA compliant lavatories (Bradley Verge LVQD2) - Electric/gas water heaters (Eemax SPEX8208T, Bradford White LC2PDV50H763X) - Air handling units and condensing units (Daikin models) - Dust collector (Torit Donaldson VS-2400) - Security cameras (Hanwha, Axis) - Wireless access points (Aruba) - Period of Performance: - 730 calendar days from Notice to Proceed - All options share the same performance period
Description
Construct North Unit Visitor Center at BADL