Opportunity
SAM #FA466126Q0095
Fire Extinguisher Maintenance, Inspection, and Certification Services at Dyess AFB
Buyer
7th Fleet
Posted
September 01, 2026
Respond By
September 11, 2026
Identifier
FA466126Q0095
NAICS
811310, 561621
This opportunity is for comprehensive fire extinguisher maintenance, inspection, and certification services at Dyess Air Force Base, Texas, managed by the Department of Defense, Department of the Air Force, Air Force Global Strike Command, and the 317th Aircraft Maintenance Squadron (317 AMXS). - Government Buyer: - Department of Defense, Department of the Air Force, Air Force Global Strike Command, FA4661 7 CONS CD - 317th Aircraft Maintenance Squadron (317 AMXS) - OEMs and Vendors: - Amerex Corporation (CAGE 54905) is the primary OEM for both 150 lb wheeled and 5 lb portable Halon fire extinguishers - Products/Services Requested: - Maintenance, inspection, and certification services for 218 fire extinguishers - Annual maintenance and hydrostatic testing for: - 158 x 5 lb Halon extinguishers (FY26) - 50 x 150 lb Halon extinguishers and 10 x 150 lb Novec extinguishers (FY27) - Key Amerex part numbers for 150 lb Model 600: 07351, 03496, 05673, 06100, 05676, 06062, 06063, 07268, 05003, 07323, 03499, 06780, 05011, 05295, 05012, 05006, 05010, 884-2 - Key Amerex part numbers for 5 lb aircraft extinguisher: FE 355T, B355T, 16155-BOTTLE, 01595, 16543, 03353, 01727, 01412, 16353, 02700, 02625, 04827, 03105, 02626, 01589, 05241, 06092, 05235, 01591, 01074, 01075, 06212, 04903, 00172, 00216, 04865, 03358, 04902, 04869, 04864, 15645, 07495, 00914, 04485 - Unique/Notable Requirements: - Contractor must provide all personnel, equipment, tools, supervision, and materials for full-service maintenance and certification - Hydrostatic testing quantities and schedule are specified and were recently updated (e.g., 158 units for 5 lb extinguishers in FY26) - Government will provide collection/delivery, Halon agent, manuals, and oversight - Services span a base year plus four option years, with annual and scheduled hydrostatic testing - Safety and handling requirements for Halon 1211 due to its hazardous nature - Maintenance procedures and replacement parts are detailed for both 150 lb and 5 lb extinguishers
Description
Amendment 1: Correct the following oversight
- To remove and replace Performance Work Statement document with updated Schedule Summary FY 26 Task 2: Hydrostatic Testing quality from 186 x 5 lb to 158 x 5 lb
- To remove and replace Section L and M document with updated submission instruction due date from 11 Sept 2025 2:00pm to 11 Sept 2026 2:00 pm CDT.
Comprehensive maintenance, inspection, and certification services for two-hundred eighteen (218) fire extinguishers at Dyess AFB, Texas.The contractor shall provide all personnel, equipment, tools, supervision and other items and services necessary to perform the functions as defined in the Performance Work Statement.