Opportunity
Lone Star College System Ionwave #CSP 26-08-10
Water Line and Aerobic Septic System Construction at Lone Star College Kingwood
Posted
August 28, 2026
Respond By
September 25, 2026
Identifier
CSP 26-08-10
NAICS
237110, 237990
Lone Star College System is seeking competitive proposals for the construction of new public water lines and an aerobic septic system at its Kingwood campus in Porter, Texas. - Government Buyer: - Lone Star College System (LSCS), Kingwood Campus, Procurement Department - City of Houston Public Works (coordination required) - Project Scope: - Construction of 8-inch and 12-inch AWWA C900 DR18 blue PVC public water mains, including trenchless crossings, valves, hydrants, and ductile iron transitions - Installation of an 8-inch private fire service line with fire-rated compound meter vault and RPZ backflow preventer - Construction and installation of an aerobic on-site sewage facility (OSSF) with drip irrigation disposal system - Site grading, drainage improvements, electrical work, surface restoration, traffic control, and SWPPP implementation - Key OEMs and Products: - Clearstream: 800-gallon Treatment Unit - Goulds: Effluent and solids pumps (20 EB 1/2 HP, 20 GPM 0.5 HP, 2-inch solids pump) - Aztec: Dual 100 Micron Filter - Netam: 0.91 GPH drip tubing - AWWA C900/C500/C151/C104: PVC and ductile iron pipe standards, valves - Products and Quantities: - 12-inch and 8-inch PVC water mains (AWWA C900 DR18) - 500-gallon pretreatment tank (1) - 800-gallon Clearstream Treatment Unit (1) - 1,080-gallon pump tank (1) - Goulds effluent and solids pumps (multiple, see line items) - Aztec Dual 100 Micron Filter (1) - Netam drip tubing (quantity not specified) - Fire hydrants, valves, meter vaults, backflow preventers, trenchless crossing (44 LF) - Services: - Complete turnkey construction, installation, testing, disinfection, startup, commissioning, and closeout - Site grading, drainage, surface restoration, traffic control, SWPPP, and maintenance agreement for OSSF - Unique Requirements: - Compliance with City of Houston, Montgomery County, TCEQ, AWWA, and OSHA standards - Registered OSSF installer required for septic system - Mandatory site visit, insurance, and Davis-Bacon wage rates - Coordination with CenterPoint Energy for gas line safety - ADA-compliant restoration and access - Estimated Contract Value: - $500,000 (project budget) - Notable OEMs: Clearstream, Goulds, Aztec, Netam (highlighted for treatment unit, pumps, filter, and drip tubing)
Description
This solicitation is a Competitive Sealed Proposal (CSP 26-08-10) issued by Lone Star College System for the construction of new 8-inch and 12-inch public water lines and an aerobic on-site sewage facility (septic system) at the Kingwood campus. The project includes installation of water mains, valves, hydrants, septic tanks, pumps, filtration, piping, electrical work, site grading, and surface restoration. The work must comply with applicable local and state regulations and standards. Proposals are to be submitted electronically and will be opened virtually on September 25, 2026.