Opportunity

Warner Robins Ionwave #26-U-4791 Addendum 1

SCADA and Control Systems Integration Services for Warner Robins Water & Wastewater Utilities

Posted

August 05, 2026

Respond By

September 11, 2026

Identifier

26-U-4791 Addendum 1

NAICS

541512, 238210, 541690

The City of Warner Robins, Georgia is seeking a qualified contractor to provide ongoing SCADA (Supervisory Control and Data Acquisition) and Control Systems Integration (CSI) maintenance, support, and capital improvement services for its water and wastewater utility systems. - Government Buyer: - City of Warner Robins, Georgia - Water and Wastewater Utility Systems - OEMs and Vendors Mentioned: - Allen-Bradley (MicroLogix 1000/1400 PLCs) - Siemens (S7-300, ET 200SP HA PLCs) - Wonderware (InTouch SCADA/HMI platform) - Hach (SC200 dissolved oxygen analyzers) - Hydro Instruments (chlorine residual and pH analyzers) - Products Requested: - PLC/RTU replacements (Allen-Bradley, Siemens, or equivalent) - SCADA/HMI platform and server hardware (Wonderware InTouch or equivalent) - Hydro Instruments chlorine residual and pH analyzers (6 units) - Hach SC200 compatible dissolved oxygen analyzers (2 units) - Industrial-grade cellular routers and radio telemetry equipment - Industrial-grade IP security cameras with 512GB SD cards - Industrial-grade true sine wave UPS units with AVR (7 units) - Services Requested: - Ongoing SCADA/CSI maintenance and technical support (task-order basis) - Capital improvement services (Task Order No. 1) - Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) - Cellular data/SIM activation and configuration - Security camera system configuration and integration - Unique/Notable Requirements: - Migration from radio to cellular telemetry for remote site communications - Unified SCADA/HMI platform for all facilities - Security camera system with central video management and encrypted VPN connectivity - Compliance with City IT/cybersecurity standards, including multi-factor authentication for remote access - Mandatory on-site pre-bid meeting for eligibility - No mandated OEMs for PLC/RTU or security cameras; proposers may recommend platforms for lifecycle support and compatibility - Warranty period of one year following completion and acceptance - Task Order No. 1 covers immediate capital improvements; future task orders anticipated - Facilities Covered: - Seven water treatment plants, three remote wells, two wastewater treatment plants, elevated tanks, and other municipal utility sites

Description

The City of Warner Robins, Georgia is soliciting proposals from qualified firms to provide SCADA and Control Systems Integration maintenance, support, and capital improvement services for its water and wastewater utility systems. The solicitation aims to establish a Master Services Agreement with one highly qualified contractor for ongoing maintenance and technical support services, structured on a task-order basis. Task Order No. 1 addresses immediate capital improvements to the City's SCADA infrastructure and is included to allow proposers to submit qualifications, maintenance/support pricing, and a proposed solution with pricing simultaneously. A mandatory on-site pre-bid meeting is scheduled to ensure proposers understand the scope and site conditions.

View original listing