This procurement opportunity is issued by the National Institutes of Health (NIH), specifically the Office of the Director (OD) and the Office of Logistics and Operations (OLAO), for the National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK). - Government Buyer: - National Institutes of Health (NIH) - Office of the Director (OD) - Office of Logistics and Operations (OLAO), Office of Acquisition and Logistics Management (OALM), Hospital and Laboratory Support Division - OEM Highlight: - Percival Scientific Incorporated is the specified Original Equipment Manufacturer (OEM) - Products Requested: - Percival Incubator (dual-sized cell incubator chamber) - Quantity: 1 - Must include: - Temperature-controlled backup system - Capacity to support an internal 70-pound shaker - Internal computer-controlled real-time cell imaging system - Designed to maintain Dictyostelium cell lines at a constant temperature of 20–24°C - Unique Requirements: - Exact replacement of the current incubator - Critical for research continuity; temperature deviations can cause cell death and loss of materials - Procurement under NAICS code 334516 - Simplified acquisition threshold not exceeding $350,000 - No specific part numbers provided - No service line items requested
Description
PERCIVAL INCUBATORS
The mission of the National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK) is to conduct and support medical research and research training and to disseminate science-based information on diabetes and other endocrine and metabolic diseases; digestive diseases, nutritional disorders, and obesity; and kidney, urologic, and hematologic diseases, in order to improve people’s health and quality of life.
Dictyostelium cell lines must be maintained at a constant temperature of 20–24 °C. Temperatures above or below this range alter their physiology, with higher temperatures causing cell death. The current system is more than 15 years old and has reliability issues, requiring several repair orders in recent years. Cell lines in this incubator were lost when the system overheated in the middle of the night. This has resulted in many weeks required to re-establish the cell lines and has led to wasted United States Government resources. The system is reaching the end of its life cycle.
An exact replacement of the current dual-sized cell incubator chamber is required, with a temperature-controlled backup system and the capacity to support an internal 70-pound shaker and an internal computer-controlled real-time cell imaging system