Opportunity

SAM #W912WJ26RA008

Replacement of Chilled Water Plant and Site Utility Upgrades at VA Medical Center, West Haven, CT

Buyer

USACE New England District

Posted

August 24, 2026

Respond By

October 23, 2026

Identifier

W912WJ26RA008

NAICS

238220, 238210, 238290, 238190, 236220, 541330

The U.S. Army Corps of Engineers, New England District, and the Department of Veterans Affairs are soliciting for the replacement of the chilled water plant and site utility upgrades at the VA Medical Center, West Haven, CT. - Government Buyer: - U.S. Army Corps of Engineers, New England District - Department of Veterans Affairs, VA Connecticut Health Care System, West Haven Campus - OEMs and Vendors: - Siemens - Johnson Controls (JCI) - Assa Abloy - AMAZ Consulting - Products and Equipment Requested: - Water-cooled chillers (part number: 17-CH-1, 1250-ton capacity, N+1 redundancy) - Air Handling Units (17-AHU-1) - Cooling towers (17-CT-1) - Fuel system (FOP-1) - Condenser water pumps (17-CWP-1) - Heat exchangers (17-HX-1) - Electric unit heaters (17-EH-1) - Heat pumps (17-HP-1) - Diesel engine generators (GEN-1) - Automatic transfer switches (17-ATS-LS1) - Building Automation System and Temperature Controls (brand-name Siemens or Johnson Controls) - Johnson Controls/Simplex fire alarm system components (control panels, pull stations, strobes, speakers, detectors, modules) - Johnson Controls electronic security system (access control, cameras, intrusion detection) - Assa Abloy Accentra Large Format lock cores - Services Requested: - Installation and programming of Johnson Controls electronic security system by certified integrators - SCADA system programming by AMAZ Consulting - Commissioning services for fire suppression, plumbing, medical gas, and HVAC systems - Unique/Notable Requirements: - All major systems must integrate with existing campus platforms (Siemens, Johnson Controls, Assa Abloy) - Brand-name restrictions for BAS, fire alarm, security, and lock core systems to ensure compatibility and security - Compliance with VA Physical Security Resiliency Design Requirements and USGBC LEED Silver certification - Commissioning, BIM standards, and interim life safety measures required - Construction must be coordinated to minimize disruption to ongoing medical center operations - Sole-source programming for SCADA system due to operational risk and proprietary integration

Description

The scope of the chilled water plant replacement consists of the demolition of the existing chilled water plant (building 16a) and construction of a new multi-story chilled water plant to include chillers, cooling towers, pumps, and all associated mechanical and electrical equipment. Due to the close proximity of the existing fuel tank farm adjacent to the existing chilled water plant, a new fuel tank farm will need to be constructed as part of the project, which primarily serves the central boiler plant, requiring close coordination with the medical center and ongoing related projects.The scope of the site utility upgrades consists of the replacement and upgrade of the existing fire protection water main and the domestic water main from Campbell Avenue to Building 15. Site utility upgrades also include providing utility main loops of chilled water supply and return, steam supply, condensate return, domestic water supply, and fire protection water supply which will originate from the new chilled water plant and back-feed to Building 1. The work also includes the installation of redundant electrical feeder from the utility demarcation point to Building 19 and coordination with the local electrical utility provider to provide further electrical redundancy offsite as well. In addition, new water storage tanks will be constructed. This project involves civil/site, mechanical, electrical, plumbing, structural, geotechnical, and architectural disciplines. The project must also comply with the DVAs Physical Security Resiliency Design Requirements (PSRDM). It is expected that the chilled water plant will be constructed to meet USGBC LEED Silver certification. The work is located adjacent to and within an active Medical Center campus which will be operational at all times. Impact to on-going operations must be kept to a minimum and carefully coordinated with the Contracting Officer and VAMC staff. In addition, the work area is constrained due to the active medical center operations which will limit laydown and storage areas during construction. Additional Links:Department of Defense Procurement ToolboxPIEE Solicitation Module Link for W912WJ26RA008Registration Instructions for the PIEE Solicitation ModuleWeb Based Training for the PIEE Solicitation Module

View original listing