Opportunity
SAM #W911S226U4210
Procurement of Toshiba 150 HP Electric Motor for hazardous environments
Buyer
MICC-Ft Drum
Posted
August 21, 2026
Respond By
August 31, 2026
Identifier
W911S226U4210
NAICS
423610, 335312
This procurement opportunity from the Department of Defense (Department of the Army, Mission Installation Contracting Command at Fort Drum) seeks a specialized electric motor for hazardous environments. - Government Buyer: - Department of Defense - Department of the Army - Mission Installation Contracting Command (MICC), Fort Drum - OEMs and Vendors: - Toshiba (OEM) - Products Requested: - Toshiba 150 HP Electric Motor - Part Number: B1504YLF4USH - Quantity: 1 - NEMA 445T frame size - Enclosure: Totally Enclosed Fan Cooled (TEFC) or Totally Enclosed Explosion Proof (TEXP) - Mount: Footed/ridged base - Construction: Rugged cast iron - Electrical: Dual-rated 230/460 VAC, 3-phase, 60 Hz, continuous duty cycle - Efficiency: NEMA Premium Efficiency - Unique/Notable Requirements: - Explosion-proof ratings for hazardous environments: - Class I, Division 1, Group D (flammable gases) - Class II, Division 1, Groups E, F, G (combustible dusts) - T3C temperature code rating - Compliance with UL and CSA safety standards for hazardous environments - Only Toshiba is specified as the OEM
Description
Item: Electric motor Brand Name: Toshiba Part Number: B1504YLF4USH Salient Characteristics: Manufacturer Toshiba Model / Part Number B1504YLF4USHFrame Size NEMA 445T Enclosure Type Totally Enclosed Fan Cooled (TEFC) / Totally Enclosed Explosion Proof (TEXP) Mounting Configuration Footed Mount / Rigid Base Construction Material Rugged Cast Iron (Frame, End Brackets, Conduit Box, and Fan Cover) Physical Dimensions Height: ~26 in, Length: ~48.4 in, Width: ~22.4 in Estimated Net Weight ~2,087 lbs. . Electrical and Performance Characteristics These performance metrics ensure compatibility with tactical or base electrical systems . Salient Characteristic Required Specification Output Power 150 HP (Horsepower) Synchronous Speed 1800RPM (Revolutions Per Minute) Operating Voltage Dual-rated 230 / 460 VAC Phase /Frequency 3-Phase, 60 Hz Service Factor 1.15 Nominal Full Load Efficiency 95.8%(NEMA Premium Efficiency compliant) Full Load Amperage 352 A (at 230V) / 176 A (at460V) Duty Cycle Continuous .. Environmental and Safety Ratings Due to the critical nature of Department of War missions and operations in hazardous areas, the motor must carry verified explosion-proof ratings to handle volatile elements. Salient Characteristic Required Specification Hazardous Environment Certifications Must be certified for: Class I, Division 1, Group D (Flammable Gases) Class II, Division 1, Groups E, F and G(Combustible Dusts) Temperature Code Rating T3C (160C maximum exterior surface temperature under fault conditions) Standards Compliance Exceeds UL and CSA safety standards for hazardous environments1 each Additional Links:Department of Defense Procurement ToolboxPIEE Solicitation Module Link for W911S226U4210Registration Instructions for the PIEE Solicitation ModuleWeb Based Training for the PIEE Solicitation Module