Contra Costa Community College District is seeking bids for the replacement of two rooftop HVAC units at Diablo Valley College Student Union. - Government Buyer: - Contra Costa Community College District, Diablo Valley College, Student Union - OEMs and Vendors: - Carrier (basis of design for rooftop units) - Automated Logic Corporation (ALC) (BAS controllers, sensors, gateways, and software) - Mamac and Kele Associates (approved for temperature sensors) - Products/Services Requested: - Two 7.5-ton Carrier heat pump rooftop units (part number: 50GEQM08A2A6-0A0A0 or 50GEQM08A2A60A0A0) - Electric resistance heating: up to 13 kW for AC-6, 11 kW for AC-7 - BACnet gateway integration for campus ALC BAS - Reuse existing roof curbs with adaptors if needed - Spring isolation required unless internally isolated - Existing duct smoke detectors and Belimo actuators may be reused - Building Automation System (BAS) upgrades: - ALC OptiFlex controllers (BC, AAC, ASC) - BACnet gateways and protocol translators (expandable by 20%) - Temperature sensors (duct/room) and differential pressure transmitters - Control transformers and power supplies - Use of existing ALC WebCTRL software license - Services: - Removal and disposal of two existing rooftop HVAC units - Installation of new units with all ductwork, piping, and electrical connections - BAS programming, commissioning, and integration - Warranty and maintenance services (2 years for controllers, 5 years for actuators, 1 year for other components) - Commissioning support and training - Unique/Notable Requirements: - Integration with campus ALC BAS via BACnet gateway - Trend logging for a minimum of 3 years after acceptance - Detailed submittals, testing, and participation in commissioning - Work to be performed during normal business hours, coordinated with building occupancy - Approved BAS contractors for controls: Sunbelt Controls, Air Systems, ASG - Warranty periods and emergency service response requirements
Description
This project involves the removal and disposal of two existing rooftop HVAC units (AC-6 and AC-7) and the installation of two new 7.5-ton heat pump rooftop units. The work includes making all necessary ductwork, piping, and electrical connections. Additional requirements include electric resistance heating, reuse of existing roof curbs with possible adaptors, spring isolation for curbs, BACnet gateway integration for campus BAS, and adjustments to electrical circuit breakers and feed wires. The project is located at 500 Court Street, Martinez, CA 94553, with a pre-bid meeting scheduled for August 27, 2026.