Opportunity
CanadaBuys #5000094586
Phased Roof Replacement and Rehabilitation at Pacific Environmental Science Centre, North Vancouver, BC
Posted
August 13, 2026
Respond By
September 02, 2026
Identifier
5000094586
NAICS
238160, 238190, 238290
Environment and Climate Change Canada (ECCC) is seeking a qualified contractor for a phased roof replacement and rehabilitation project at the Pacific Environmental Science Centre in North Vancouver, BC. - Government Buyer: - Environment and Climate Change Canada (ECCC), Division of Real Property Management, Technical Services - Pacific Environmental Science Centre (CSEP) - Scope of Work: - Removal and replacement of low-slope roofing systems, including SBS modified bitumen assemblies and PMMA liquid-applied membranes - Replacement and repair of insulation, vapor barriers, cover boards, metal flashings, drains, scuppers, overflow drains, and localized structural repairs (steel decking, plywood decking, wood blocking, wall panels) - Site setup, permits, insurance, bonding, project management, and commissioning support - Mechanical, electrical, and plumbing coordination, including removal/reinstallation of rooftop equipment and gas lines - Painting of exposed metal components and installation of new roof access hatch - Temporary weatherproofing and protection during construction - Hazardous Materials: - Lead-based paints identified on metal flashings (blue and light green), lead-containing plumbing/soil stack flashing, and silica-containing masonry walls - Contractor must follow safe handling and abatement procedures for hazardous materials - Notable Requirements: - Minimum 10 years of relevant roofing experience - Membership in the Roofing Contractors Association of British Columbia - Valid licensing to perform roofing work in BC - Compliance with federal, provincial, and municipal environmental regulations - Quality assurance documentation, safety plans, and training for ECCC personnel - Security requirements and insurance - Products/Services Requested: - SBS Roofing and Insulation - PMMA membrane applications - R35 polyisocyanurate insulation (alternate) - Replacement of wood blocking, exterior wall panels, plywood decking, 2-ply SBS membrane, steel deck repairs/replacement - Gutter liners, roof access hatch, and commissioning support - No specific OEMs or named vendors; open to competitive bids from qualified contractors - Contract must be completed within 6 to 8 months, ending no later than March 31, 2027
Description
The solicitation is for the phased roof replacement and rehabilitation of multiple low-slope roofing areas at the Pacific Environmental Science Centre (PESC) in North Vancouver, British Columbia. The work includes removal and replacement of roofing systems, flashings, insulation, drains, sheet metal components, localized deck repairs, and PolyMethyl MethAcrylate (PMMA) membrane applications. The contractor must provide all labor, materials, equipment, supervision, and services necessary to deliver a fully compliant, watertight, code-compliant roofing system with warranties and quality assurance. The work must be completed by March 31, 2027.