Opportunity
SAM #36C24626Q0940
Replacement of Durag D-R 290 Opacity Units Gen 2 at Asheville VA Medical Center
Buyer
Veterans Affairs National Cemetery Administration
Posted
August 14, 2026
Respond By
August 21, 2026
Identifier
36C24626Q0940
NAICS
238220, 238210, 811219, 333415, 238290, 541330
The Department of Veterans Affairs, Network Contracting Office 6, is seeking a contractor to replace two Durag D-R 290 Opacity Units Gen 2 at the Charles George VA Medical Center in Asheville, NC. - Government Buyer: - Department of Veterans Affairs - Network Contracting Office 6 - Charles George VA Medical Center - OEMs and Vendors: - Durag (manufacturer of D-R 290 Opacity Units Gen 2 and related components) - MOXA (manufacturer of I/O cards) - Dell (manufacturer of PowerEdge R360 Silver StackVision Server) - Products Requested: - 2 Durag D-R 290 Opacity Units Gen 2 (part number: Durag D-R 290) - 1 D-ESI 100 Software Set (part number: D-ESI 100) - 2 D-R 290 G2 Transceivers (part number: D-R 290 G2) - 2 Reflector 1 units (part number: Reflector 1) - 2 Weather Protective Covers for Transceiver - 2 Weather Protective Covers for Reflector - 2 Steel Blower Enclosures with Filter Assembly - 2 D-ISC 100M Modular Controllers (part number: D-ISC 100M) - 2 Sensor Connection Cables - 2 D-ISC Digital Input Modules - 2 D-ISC Digital Output Modules - 2 D-ISC Modbus RTU modules - 2 D-ISC Modbus TCP modules - 2 Regenerative Blowers - 2 New Blower Air Filter Housings with Filter and Bracket - 4 Air Purge Kits - 2 Purge Air Hoses - 2 Y-Joints - 4 Hose Clamps - 2 Packing/Handling/Crating - 2 Sets of Manuals - 2 Kits for Reusing Existing Adaptor Flanges - 1 Model 8864 Compact Data Controller (part number: 8864) - 1 PowerEdge R360 Silver StackVision Server (Tower) - 1 8-port Unmanaged Ethernet Switch DIN Mount - 2 MOXA I/O Card 8 Analog Inputs - 2 MOXA I/O Card 16 Digital Inputs - Services Requested: - Removal of existing opacity systems - Installation and verification of new Durag D-R 290 Opacity Units Gen 2 - Integration with StackVision Data Acquisition System - Startup, calibration, audit filter tests, response time tests - Two mobilizations, six man-days total with two field service technicians - Unique Requirements: - Integration with StackVision Data Acquisition System - Engineering review and drawing updates for reusing existing adaptor flanges - Firm-fixed-price contract - Set aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB)
Description
Opacity System Replacement for the Asheville VA Medical Center