Opportunity
SAM #F9YGC0
Sources Sought for Raised Access Floor System at Sepulveda Air National Guard Station
Buyer
W7MX USPF Activity CAANG 195
Posted
August 13, 2026
Respond By
August 26, 2026
Identifier
F9YGC0
NAICS
337215, 238290
The Department of Defense, Department of the Army, National Guard Bureau (USPFO CA Procurement, W7MX USPFO ACTIVITY CAANG 195) is seeking sources for a comprehensive, turn-key raised access floor system for a Security Operations Center at Sepulveda Air National Guard Station, Van Nuys, California. - No specific OEMs or vendors are named in the notice; the government is seeking information on standard commercial products that meet the requirements. - Requirements for the raised access floor system: - Modular, non-permanent design covering approximately 2,800 square feet - Certified minimum concentrated load rating of 1,250 lbs - Constructed from non-combustible, data-center-grade materials with a Class A flame spread rating - Uniform finished floor height of 6 inches - ADA-compliant ramps for accessibility - Integrated ESD-rated surface finish and grounding for electrostatic discharge mitigation - Cable management features for power and data routing - Support for relocatability and future reconfiguration - Lifecycle support requirements: - Commercial parts and labor warranty - Operation and maintenance (O&M) manuals - As-built drawings - Warranty on compatible replacement parts - Respondents are asked to provide: - Information on their standard commercial products that meet or exceed these requirements - Industry feedback on procurement and installation best practices
Description
This Sources Sought Notice (SSN) is for planning and market research purposes only and shall not be construed as a solicitation, Invitation for Bid (IFB), Request for Quotation (RFQ), or Request for Proposal (RFP). This notice does not commit the Government to contract for any supply or service. The Government will not pay for any information or administrative costs incurred in response to this SSN; all costs associated with responding will be solely at the interested party’s expense.
Subject: Raised Access Floor System Notice Type: Sources Sought / Market Research NAICS Code: 337215 – Showcase, Partition, Shelving, and Locker Manufacturing (Size Standard: 500) PSC Code: PSC 7220 Floor Coverings Place of Performance: Sepulveda Air National Guard Station, Van Nuys, CA 91409
Background & Requirements
The Government is seeking potential sources capable of providing a comprehensive, turn-key solution to deliver, install, and support a safe, modular, and robust raised access floor system for a mission-critical Security Operations Center (SOC) environment
The core parameters of the draft Statement of Objectives (SOO) include:
Footprint: Approximately 2,800 square feet. Load Rating: Certified minimum concentrated load rating of approximately 1,250 lbs to support heavy IT equipment and operator consoles. Materials: Non-combustible, data-center-grade materials with a Class A flame spread rating. Height & Access: Uniform level finished floor at a height of 6 inches. Must include ADA-compliant ramps that safely accommodate the floor height and existing facility doorways. Electrostatic Discharge (ESD) Mitigation: Integrated ESD-rated surface finish and grounding to protect sensitive SOC electronics. Cable Management: Support for routing power and data cables underneath, enabling the pass-through of existing electrical whips from furniture to subfloor outlets without requiring hardwiring by the contractor. Relocatability: Modular and non-permanent installation (not annexed to the building structure) to allow future reconfiguration/relocation without facility damage. Lifecycle Support: Commercial parts and labor warranty, O&M manuals, as-built drawings, and commercial equivalent warranty on compatible replacement parts
Capability Statement Submission Requirements
Interested businesses are requested to submit a Capability Statement demonstrating their ability to fulfill the Government’s needs. Submissions must include the following information:
Section A: Corporate Profile
Company Name, Address, and Website. Point of Contact (Name, Title, Phone, and Email). Unique Entity Identifier (UEI) and CAGE Code. Business Size and Socio-Economic Status under NAICS 337215 (e.g., Large Business, Small Business, Service-Disabled Veteran-Owned Small Business [SDVOSB], Women-Owned Small Business [WOSB], 8(a), HUBZone). Specify if your firm holds any Federal contract vehicles (e.g., GSA MAS, 8(a) STARS III, NASA SEWP, or regional IDIQs) that cover these types of commercial flooring installations.
Section B: Technical Capability
Provide a brief description of standard commercial products your firm can supply that meet or exceed the 1,250 lbs concentrated load, Class A flame spread rating, and integrated ESD grounding requirements.
Section C: Industry Feedback
To help the Government refine the acquisition strategy, please provide brief responses to the following questions as an appendix to your capability statement:
In your commercial practice, is a project of this nature normally procured as a Construction project or a Commercial Item Supply with Installation Services? Are there specific cost-drivers in the draft SOO (e.g., the 6-inch height limitation, the 1,250 lbs load capacity, or the non-permanent relocatability requirement) that will disproportionately affect pricing? What is the typical commercial lead time for manufacturing, delivering, and installing a 2,800 sq ft access floor system after receiving a formal award? Are there any areas in the draft SOO that require clarification, or are there commercial best practices for data center flooring that the Government should consider adding to the requirements? If this requirement is set aside for Small Businesses, are there sufficient qualified manufacturers and installers in your socio-economic category to ensure a highly competitive bidding pool? The Government’s goal for 'relocatability' is to allow for future reconfiguration without structural damage. What is your standard commercial installation method (e.g., pedestal adhesive, free-standing)? Does this method meet our goal? Do your standard commercial offerings that meet the 1,250 lbs load rating typically include an integrated ESD finish and Class A flame spread rating, or are these features that add significant cost?
Response Submission Instructions
Please submit your response electronically in PDF format to 195WG.FAL.MSC.Contracting.Org@us.af.mil and carmen.ridener@us.af.mil no later than 26 August 2026 at 4:00 PM PDT.
The subject line of the email should read: "Response to Sources Sought: Access Floor System - [Your Company Name]".
Disclaimer
Not responding to this SSN does not preclude participation in any future solicitation, if issued. If a solicitation is released, it will be synopsized on the Government-wide Point of Entry (GPE) or GSA eBuy. It is the responsibility of the potential responders to monitor these sites for additional information.
Please note, if a solicitation or multiple solicitations are posted in the future, they will be issued by a separate solicitation. The Government may hold virtual industry day sessions or one-on-one meetings with respondents to discuss their capabilities and feedback in more detail.