Sole Source BAS Replacement and Upgrade at VA Medical Center (Wind Water Controls)
Buyer
VA Network Contracting Office 5
Posted
August 12, 2026
Respond By
August 18, 2026
Identifier
36C24526Q0772
NAICS
238220, 541330, 238210, 541512
This notice announces the Department of Veterans Affairs' intent to sole source a Building Automation System (BAS) replacement and upgrade at the Louis A. Johnson VA Medical Center. - The project covers: - Removal of the existing proprietary BAS, including Metasys ADX server and proprietary supervisory controllers (Johnson Controls) - Installation of a new, fully open, non-proprietary BAS platform - Integration of all critical HVAC equipment (boilers, chillers, air handlers, VAVs, exhaust fans, terminal units) - System must support real-time monitoring, trending, alarming, scheduling, and optimization - Emphasis on minimal operational disruption and seamless transition - Future expandability, interoperability, and owner control without proprietary software or licenses - Wind Water Controls is identified as the intended sole source vendor - No specific OEMs or part numbers for the new system are listed; Metasys ADX (Johnson Controls) is the incumbent system - Opportunity is a sole source justification, but details may interest BAS manufacturers and integrators
Description
Building Automation System Replacement and Upgrade Department of Veterans Affairs Louis A. Johnson VA Medical Center GENERAL DESCRIPTION: The Louis A. Johnosn VAMC requires the replacement and upgrade of the existing Building Automation System (BAS). The project shall include complete removal of the outdated and proprietary BAS and installation of a new, fully open, non-proprietary platform that provides comprehensive monitoring and control of the facility s HVAC systems, chiller & boiler plants, and other mechanical systems.
The intent is to ensure future expandability, interoperability, and owner control without reliance on proprietary software or licenses. GOALS and OBJECTIVES: Remove the existing proprietary supervisory controllers and replace them with non-proprietary supervisory controllers. Remove the existing Metasys ADX server and replace it with a non-proprietary server. Integrate all critical HVAC equipment including boilers, chillers, air handlers, VAVs, exhaust fans, and terminal units. Ensure real-time monitoring, trending, alarming, scheduling, and system optimization Minimize operational disruption and ensure seamless transition
Additional Links:Clarksburg VAMC