Opportunity

SAM #36C24826Q0990

Sole Source Targeted Metabolomics Analysis Service for VA Research Study

Buyer

VA Network Contracting Office 8

Posted

August 11, 2026

Respond By

August 17, 2026

Identifier

36C24826Q0990

NAICS

541715

This opportunity is a sole source service contract for targeted metabolomics analysis supporting a VA research study on traumatic brain injury. - Agency: Department of Veterans Affairs, Network Contracting Office 8 (James A. Haley VA Medical Center) - Contract Type: Sole source, one-time service contract - Prime Vendor: Lovell Government Services - Analytical Work Performed By: Metabolon, Inc. - Services Required: - Targeted quantitation of short-chain fatty acids in 64 plasma samples - Targeted quantitation of bile acids in 40 fecal samples - Total of 104 biological samples - Includes biosolid matrix processing for fecal samples - Deliverables: Sample analysis reports, quality control (QC) performance information, and electronic data tables - No statistical analysis or interpretation included - Customer must prepare and ship samples per Metabolon's requirements and provide a CSV manifest - Samples destroyed 90 days after project completion unless otherwise specified - NAICS Code: 541715 (Research and Development in Biotechnology, except Nanobiotechnology) - Period of Performance: August 17, 2026 – August 16, 2027 (one year), with a 6-8 week turnaround from sample receipt - No equipment, goods, software, or licenses are being purchased - Only analytical services are included - Commercial opportunity is limited due to sole source justification, but similar companies may offer comparable services in future opportunities

Description

GENERAL: James A. Haley VA Medical Center, 13000 Bruce B. Downs Blvd., Tampa, Florida 33612, intends to solicit sole source to Lovell Government Services for a one-time service contract with Metabolon, Inc. for targeted metabolomics analysis of 104 total samples (64 plasma samples and 40 fecal samples) from a VA research study. This requirement is for an analytical research service only; it does not include the purchase of goods, equipment, software, or licenses.

BACKGROUND: The project is titled "Amnion cell secretome mediated therapy for traumatic brain injury." The samples are from the aged VA r-mTBI/ST266 mouse cohort. Male and female C57BL/6J mice received repetitive mild TBI or sham injury at 3 months of age, followed by delayed intranasal ST266 or vehicle treatment beginning at 18 months post-injury and continuing for 4 months until euthanasia at 24 months post-injury/27 months of age. The delayed-treatment design models aged Veterans with chronic effects of prior neurotrauma and supports analysis of sham/TBI, vehicle/ST266, sex, and aged endpoints.

PURPOSE: The purpose is to obtain quality-controlled targeted metabolomics data needed to support the VA research project. Metabolon will provide non-GCP absolute quantitation/measurements for a Short Chain Fatty Acid Targeted Panel (9 metabolites) in plasma and a Bile Acid Targeted Panel (21 metabolites) in fecal samples. The resulting data tables and analysis reports will support evaluation of metabolite changes associated with injury status and ST266 treatment.

SCOPE: Metabolon will analyze 64 plasma samples and 40 fecal samples, for a total of 104 samples. The quoted services include: (1) Short Chain Fatty Acid Targeted Panel for plasma; (2) Bile Acid Targeted Panel for feces; and (3) biosolid matrix processing for fecal samples. Deliverables include sample analysis reports describing reference chemicals and matrices used, QC performance information, and data tables with sample results. No statistical analysis or interpretation is included in the quoted service. Customer responsibilities include preparing and shipping samples according to Metabolon procedures and providing the required sample manifest in CSV format.

PHYSICAL CHARACTERISTICS: No equipment or physical goods will be delivered to VA. The PRINCIPAL Investigator (Dr Benoit mouzon) will provide biological specimens to Metabolon for analysis: 64 plasma samples at approximately 160 uL each and 40 fecal samples at approximately 4 to 5 stool pellets per sample. Samples will be shipped according to Metabolon's sample preparation and shipping procedures. Default sample disposition is destruction 90 days after project completion unless otherwise modified by approved change order.

FUNCTIONAL AND PERFORMANCE CHARACTERISTICS: The contractor must perform targeted metabolite quantitation using appropriate validated analytical methods for the specified sample matrices, apply QC review, and provide electronic data tables and reports suitable for research use. The service must cover the requested short-chain fatty acid and bile acid analytes, process biofluid and biosolid matrices, and deliver quality-controlled results. Standard turnaround time is 6-8 weeks from receipt of samples and all necessary information, after execution of the agreement and receipt/verification of the sample manifest.

PERIOD PERFORMANCE: 8/17/2026 to 8/16/2027.

The North American Industry Classification System (NAICS) code is 561714, Research and Development in Biotechnology (except Nanobiotechnology).

Any information regarding this requirement must be received no later than 8/17/2026 @ 10:00 AM EST. Please provide a letter from the manufacturer stating authorization to work with Lovell Government Services.

DISCLAIMER This request for information is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this request for information that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.

View original listing