This notice announces the VA's intent to award a sole source contract for a specialized quality assurance system for stereotactic radiosurgery (SRS): - The Department of Veterans Affairs (VA), Veterans Health Administration, Network Contracting Office 12 (NCO 12) in Milwaukee, WI, seeks to procure the isoPoint Isocenter Characterization System from Aktina Corp. - This system is for the Clement J. Zablocki VA Medical Center's SRS Program. - The isoPoint system is a proprietary solution that includes: - Stereo camera pod - Tracking modules - Precision mechanical markers - Specialized software for 3D mechanical isocenter analysis and quality assurance of Elekta Versa HD LINAC systems - The system must achieve sub 0.01 mm mechanical precision and provide full 3D mechanical axis characterization, which is critical for clinical SRS standards. - Aktina Corp. is the sole manufacturer and exclusive provider; no other vendors are known to meet these technical requirements. - Interested parties must demonstrate technical equivalency, manufacturing authorization, and ability to meet the precision and installation requirements. - Responses are due by August 18, 2026, 5:00pm Eastern Time.

Description

Intent to Sole Source The Department of Veterans Affairs (VA), Veterans Health Administration (VHA), Network Contracting Office (NCO) 12 in Milwaukee, WI, intends to award a firm fixed price purchase on a sole source basis to: AKTINA CORP. 360 N ROUTE 9W CONGERS, NY 10920-1420

This action is for the acquisition of the isoPoint Isocenter Characterization System. This procurement supports the Clement J. Zablocki VA Medical Center, Stereotactic Radiosurgery (SRS) Program, located at 5000 W. National Avenue, Milwaukee, WI 53295. This notice of intent is not a request for competitive proposals. No solicitation document is available, and no request for quotes will be issued. The Government requires the isoPoint Isocenter Characterization System, a proprietary optical tracking and 3D mechanical isocenter analysis solution used for precision quality assurance of stereotactic radiosurgery operations. The system consists of: Stereo camera pod Tracking modules Precision mechanical markers Software capable of 3D characterization, mechanical axis assessment, collimator and couch analysis, and beam to target error computation The isoPoint system will enhance the accuracy and efficiency of quality assurance for the facility s Elekta Versa HD LINAC, providing real time 3D mechanical data not achievable through existing Winston Lutz methodologies. The system s capability to achieve sub 0.01 mm mechanical precision is critical to maintaining clinical standards for the SRS program. Aktina Medical is the sole manufacturer and exclusive provider of the isoPoint Isocenter Characterization System. The isoPoint is the only known system capable of conducting direct mechanical rotational axis measurements of LINAC subsystems and generating a full 3D error matrix. Other QA tools rely on image based estimation and lack the ability to perform subsystem specific mechanical characterization. Only Aktina Medical s isoPoint system meets the clinical, technical, and operational requirements necessary to safely support the facility s stereotactic radiosurgery program. Interested parties may submit a capability statement that demonstrates the ability to provide an item equal to or exceeding the functional characteristics of the required isoPoint system. Responses must include: Technical specifications showing equivalency Proof of manufacturing authorization Evidence of ability to meet sub 0.01 mm mechanical precision and full 3D mechanical axis characterization Delivery and installation capability Responses are due: August 18, 2026 at 5:00pm Email responses to: Stacy.Massey@va.gov Include: Intent to Sole Source isoPoint in the subject line. No telephone inquiries will be accepted. If no responses meeting the Government s requirements are received, the VA will proceed with the sole source procurement.

View original listing