Opportunity

SAM #DOIEFBO260010

Sole Source Water Quality Monitoring System for Ohmsett Facility

Buyer

BSEE Acquisition Management Division

Posted

August 06, 2026

Respond By

August 17, 2026

Identifier

DOIEFBO260010

NAICS

238210, 334516, 541330, 238290

This opportunity involves a sole source procurement for a turnkey water quality monitoring system at the Ohmsett National Oil Spill Response Research & Renewable Energy Test Facility. - Government Buyer: - Department of the Interior - Office of Acquisition and Property Management - Marine Minerals Administration - OEM and Vendor: - NIC Systems (sole source, incumbent SCADA integrator) - Products Requested: - Panel-mounted, fully integrated water quality monitoring system - Industrial-grade analyzers for chlorine, pH, ORP, temperature, salinity/conductivity, turbidity, and dissolved oxygen - Mechanical tapping and piping using corrosion-resistant materials - SCADA/HMI integration (communication protocols, register maps, scaling factors, loop-testing) - As-built drawings, O&M manuals, commissioning, and operational verification - Notable Requirements: - System must integrate with existing SCADA/HMI environment at Ohmsett - Facility access and incumbent integration experience required - Comprehensive documentation and operational verification - Contract Type: - Firm fixed price, simplified acquisition procedures - Period of Performance: - 180 days after award

Description

NOTICE OF INTENT TO SOLE SOURCEWater Quality Scanning at Ohmsett1. Proposed ActionThe NOI is issued by the Office of Acquisition and Property Management, on behalf of the Marine Minerals Administration (MMA), formerly the Bureau of Safety and Environmental Enforcement (BSEE) and Bureau of Ocean Energy Management (BOEM). This Notice is issued in accordance with Revolutionary Federal Acquisition Regulation (FAR) Overhaul (RFO) Part 5.101, Presolicitation Notice. The purpose of this Notice is to announce the government's intent to issue a sole source contract under the authority of RFO Part 12 for a Firm Fixed Price commercial contract to NIC Systems under RFO 12.102(a) for the procurement, installation, and integration of a turnkey water quality monitoring system at the Ohmsett facility.2. Description of RequirementMMA requires a contractor to provide a fully integrated, panel mounted water quality monitoring system, including:-Industrial grade analyzers for chlorine, pH, ORP, temperature, salinity/conductivity, turbidity, and dissolved oxygen.-Mechanical tapping and piping work from the Filter Room Building to the monitoring panel, including corrosion resistant piping, valves, fittings, and drainage.-Complete SCADA/HMI integration, including communication protocols, register maps, scaling factors, and validated loop testing.-As built drawings, SCADA points list, O&M manuals, commissioning, and operational verification.Place of Performance:Ohmsett National Oil Spill Response Research & Renewable Energy Test FacilityNaval Weapons Station Earle WaterfrontLeonardo, NJ 07737Estimated Value: Below Simplified Acquisition Threshold.Period of Performance: 180 days ARO3. AuthorityThis acquisition is being conducted under RFO 12.102(a), which implements 41 U.S.C. Section-1901 simplified acquisition procedures for commercial products and services at or below the Simplified Acquisition Threshold. Under this authority, the Government may proceed with award to only one responsible source when market research clearly indicates that no other supplies or services will satisfy agency requirements.4. Rationale for Sole SourceNIC Systems is the incumbent SCADA/HMI integrator supporting operations at Ohmsett and is the only source with:-Proven and validated experience integrating equipment into Ohmsett's SCADA environment.-Has a unique understanding of the existing SCADA/HMI architecture, safety interlocks, alarms, and operational data flows.-The ability to perform SCADA protocol alignment, register mapping, scaling, and full loop testing without risk to ongoing operations.-Established capability to meet Naval Weapons Station Earle access, security, and identity verification requirements.Based on market research, NIC Systems was identified as the only known source capable of meeting the requirement.5. Industry Feedback OpportunityThis notice is not a request for competitive quotes.However, any responsible source that believes it can meet the Government's full requirements may submit a capability statement no later than August 17, 2026 @ 10AM EST.Capability statements must demonstrate:-Full SCADA/HMI integration experience with comparable industrial systems;-Ability to coordinate with existing SCADA architecture without disrupting operations;-Mechanical installation experience (tapping/piping) suitable for a large scale test tank facility;-Compliance with Naval Weapons Station Earle access and security requirements.Responses must be emailed to: william_rilee@ios.doi.gov (with the "DOIEFBO260010" in the subject line)6. Response InstructionsResponses must include:-Contractor name, UEI, address-Technical capability statement directly addressing the required SCADA/HMI integration-Past performance relevant to industrial automation and water quality instrumentation-Business size classification under NAICS 334513-Point of contact information7. DisclaimerThis synopsis does not commit the Government to award a contract. A determination not to compete this requirement based on responses to this notice is solely within the Government's discretion. The Government will not reimburse any costs incurred in preparing or submitting a response to this notice.8. Other: A redacted version of the sole source justification is attached to this notice in accordance with applicable publicizing requirements.

View original listing