Opportunity
Iowa Impacs #005-RFB-2942-2027
Iowa Seeks Contractor for Automated Steam Valve Refit at Mount Pleasant Correctional Facility
Posted
August 01, 2026
Respond By
August 17, 2026
Identifier
005-RFB-2942-2027
NAICS
238290, 811310
This opportunity involves the refitting of automated steam valves and associated piping at the Mount Pleasant Correctional Facility, Building 20, for the Iowa Department of Administrative Services. - Government Buyer: - Iowa Department of Administrative Services - Project Scope: - Demolition and removal of existing steam pressure-reducing valves (PRVs), actuated valves, piping, and fittings - Installation of new steam PRV station - Fabrication and installation of a new 4-inch steam header with six 2-inch threaded outlets for new actuated valves - Installation of a 4-inch steam relief line routed to the building exterior - Installation of unions and isolation valves on both inlet and outlet sides of each reducing and automatic valve - Piping supports and water heater steam tie-in - Testing, commissioning, and integration with controls vendor - Provision of as-built drawings, O&M manuals, and commissioning report - One-year warranty on all work performed - Products/Services Requested: - New steam PRVs (quantity not specified) - 4-inch steam header (1 unit) - Six 2-inch steam actuated valves - 4-inch steam relief line (1 unit) - Unions and isolation valves - Demolition, installation, welding, testing, commissioning, and documentation services - Unique/Notable Requirements: - All work must comply with applicable codes and standards - Contractor must provide all supervision, labor, materials, tools, equipment, and transportation - Facility is a minimum-security correctional institution focused on re-entry and community integration - One-year warranty on workmanship and materials - No specific OEMs or vendors are named in the solicitation.
Description
This solicitation is a Request for Bids (RFB) for the refitting of automated valves at Building 20 of the Mount Pleasant Correctional Facility in Iowa. The project involves demolition and removal of existing steam pressure-reducing valves and associated piping, installation of new steam PRV stations, fabrication of steam headers, installation of relief piping, valve installation, piping supports, water heater steam tie-in, steam backfeed re-integration, and testing and commissioning. The contractor must provide all supervision, labor, materials, tools, equipment, and transportation necessary to complete the work in compliance with applicable codes and standards. The contract includes a one-year warranty on all work performed.