Opportunity

SAM #W911S226U3863

Chemical Storage Building Procurement for Fort Drum, NY

Buyer

MICC-Ft Drum

Posted

July 29, 2026

Respond By

August 07, 2026

Identifier

W911S226U3863

NAICS

332311, 332312, 332999, 238290

This opportunity from the Mission Installation Contracting Command (MICC) at Fort Drum, NY seeks a specialized chemical storage building for hazardous materials. - Government Buyer: - Department of the Army, MICC Fort Drum - OEMs and Vendors: - No specific OEMs or vendors are named in the solicitation - Products/Services Requested: - Chemical storage building with minimum dimensions: 42 ft x 8 ft x 8 ft 3 in - Double door with padlock-compatible handle - Sump with at least 1200-gallon capacity for spill containment - Fire-rated walls (minimum 4-hour) and roof (minimum 3-hour), tested by Intertek - 12-space, 100-amp NEMA 3R main breaker panel - Two Class 1, Division 2 explosion-proof LED light fixtures - Dust/vapor-resistant exterior light with photocell - Explosion-proof exhaust system rated for 335 CFM or higher - Grounding kit - Three-tier shelving - Skid-resistant steel ramp - Three 10-pound ABC dry chemical fire extinguishers - Unique/Notable Requirements: - Strict fire safety and spill containment features - Compliance with NFPA/UFC codes for hazardous material storage - Delivery to Building P-91, Railroad Street, Fort Drum, NY

Description

The chemical storage building must meet several specifications for construction, safety, and utility. The required minimum dimensions are 42 feet in length, 8 feet in width, and 8 feet 3 inches in height. Access shall be provided by a 60-inch by 80-inch set of double doors, with at least one 36-inch active leaf, centered on one of the 42-foot walls and secured with a padlock-compatible handle. For spill containment, the building must include a sump with a minimum capacity of 1200 gallons.The structure must feature a robust fire-rated design, with walls tested by Intertek for a minimum 4-hour rating and a roof tested for a minimum 3-hour rating. Electrical specifications include a 12-space, 100-amp NEMA 3R main breaker panel (120V/240V), two Class 1, Division 2 explosion-proof LED light fixtures with a switch for the interior, and a dust/vapor-resistant exterior light with a photocell installed outside the hazard zone. Ventilation will be handled by an explosion-proof exhaust system rated for 335 CFM or higher, suitable for petroleum-based storage and compliant with all NFPA/UFC codes, complete with an indicator light and an emergency shut-off switch.For safety and functionality, the building shall be equipped with a grounding kit including an 8-foot ground rod, 10 feet of cable, and a clamp. The interior will be furnished with three-tier, 5-foot-long shelves that are 14 inches deep with a 2-inch lip. A non-perforated, skid-resistant steel ramp, measuring at least 52 inches wide by 72 inches long, must be included. Additionally, the unit shall come with three 10-pound ABC dry chemical fire extinguishers: two installed inside on either side of the door, and one mounted outside in a weatherproof cabinet. The completed chemical storage building is to be delivered to Building P-91, Railroad Street, Fort Drum, NY 13602. Additional Links:Department of Defense Procurement ToolboxPIEE Solicitation Module Link for W911S226U3863Registration Instructions for the PIEE Solicitation ModuleWeb Based Training for the PIEE Solicitation Module

View original listing