Opportunity
SAM #36C24826Q1018
Procurement of Philips Neximer Laser System for Cardiology at James A. Haley Veterans Hospital
Buyer
VA Network Contracting Office 8
Posted
July 29, 2026
Respond By
August 06, 2026
Identifier
36C24826Q1018
NAICS
339112, 423450
The Department of Veterans Affairs, Network Contracting Office 8 (NCO 8), is soliciting offers for a Philips Neximer Laser System for the James A. Haley Veterans Hospital Cardiology Section in Tampa, FL. - Government Buyer: - Department of Veterans Affairs, Network Contracting Office 8 (NCO 8), James A. Haley Veterans Hospital - OEM Highlight: - Philips is the sole Original Equipment Manufacturer (OEM) specified for the required laser system - Products Requested: - Philips LAS-100 Neximer Laser System - Quantity: 1 unit - Description: Image-guided excimer laser system for interventional cardiology, used in cardiac catheterization procedures to treat coronary and peripheral vascular issues and for cardiac lead management - Features: Touchscreen guided workflows, 360-degree maneuverability, supports coronary and peripheral atherectomy and lead extraction - Standard manufacturer warranty required; extended warranties are not accepted - Notable Requirements: - The system is intended to replace an end-of-life laser in the hospital's Cardiology Section - Only certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) are eligible to compete - Delivery is required within approximately 3 months after order receipt - No specific part number is provided in the documentation - The procurement is a firm-fixed-price contract
Description
GENERAL: James A. Haley Veterans Hospital (JAHVH) located at 13000 Bruce B Downs Blvd Tampa, Florida 33612, has a requirement for the procurement of the Philips Neximer Laser system for use within the Cardiology Section of Medicine and Specialty Care. PURPOSE: Neximer lasers are image-guided excimer laser systems used in interventional cardiology to treat a range of coronary and peripheral vascular problems, as well as certain cardiac lead management issues. SCOPE: JAHVH Tampa Medicine and Specialty Care is requesting Philips Neximer PHYSICAL CHARACTERISTICS: Equipment must have physical characteristics to enable the government to perform the capabilities in accordance with the Statement of Need RFQ Responses are due at 12:00PM on 8/6/2026. Questions in response to this solicitation may be emailed to Katrina.tavares@va.gov NO LATER THAN 2:00PM on 8/3/2026.
Additional Links:Department of Veterans Affairs