Opportunity

SAM #W911S226U3818

Solicitation for Advanced Plate Reader Instrument for West Point

Buyer

MICC-Ft Drum

Posted

July 24, 2026

Respond By

August 06, 2026

Identifier

W911S226U3818

NAICS

334516, 334519, 423490

The Mission Installation Contracting Command (MICC) at Fort Drum, Department of the Army, is seeking a plate reader instrument for West Point, NY. - Government Buyer: - Department of the Army - Mission Installation Contracting Command (MICC) Fort Drum - For use at West Point, NY - Products/Services Requested: - Plate reader instrument for laboratory use - Must support real-time data acquisition in multiple measurement modes: - Monochromator-based fluorescence - UV/Vis absorbance (dedicated spectrometer, not monochromator) - Luminescence - Key technical requirements: - Linear variable monochromator with tunable band passes up to 100nm - Tunable dichroic mirror for air-based light path - Auto-ranging detector sensitivity and gain for fluorescence measurements below 760,000,000 counts - Enhanced dynamic range autoranging in less than 0.1s - Full UV/Vis absorbance spectrum from 220nm-1000nm at 1nm resolution in less than 0.5s - Heated optics and optical head - Temperature controller up to 45°C - Bottom reading capability - Two reagent injectors for automated injection - Atmospheric control unit with software-controlled CO2 and O2 concentrations for cell culture - Accompanying software for data visualization and analysis - No specific OEMs, vendors, part numbers, or purchase quantities are specified - Notable requirements: - Instrument must include advanced features for cell culture and data analysis - Emphasis on speed, sensitivity, and flexibility in measurement modes

Description

We require an instrument that can acquire real-time data from multiple modes of measurement, including monochromator-based fluorescence, UV/Vis absorbance, and luminescence. We require the following: linear Variable Monochromator, permitting tunable band passes up to 100nm; a tunable dichroic mirror permitting air-based light path for monochromator without light guides or fiberoptics; auto ranging of detector sensitivity and gain for fluorescence measurements below 760,000,000-counts; enhanced Dynamic Range autoranging of detector sensitivity in less than 0.1s; absorbance based on a dedicated spectrometer, not a monochromator. Complete UV/Vis absorbance spectrum from 220nm-1000nm at 1nm resolution in less than 0.5s with all wavelengths captured simultaneously with a diode array; heated optics. A heated optical head means that incubated microplate wells remain in a uniform temperature environment even during detection. The instrument should have a temperature controller than can go up to 45 �C, bottom reading, two reagent injectors for automated injection for initiating kinetic events and flash luminescence, and an atmospheric control unit with software-controlled CO2 andO2 concentrations for cell culture at 5% CO2. The unit should come with software for data visualization and analysis. Additional Links:Department of Defense Procurement ToolboxPIEE Solicitation Module Link for W911S226U3818Registration Instructions for the PIEE Solicitation ModuleWeb Based Training for the PIEE Solicitation Module

View original listing