Opportunity
SAM #FDA-75F40126Q00320
FDA Multi-Year Nitrogen Generator Maintenance Contracts for Five Lab Locations
Buyer
FDA Office of the Associate General Counsel for Administrative Law
Posted
July 22, 2026
Respond By
August 05, 2026
Identifier
FDA-75F40126Q00320
NAICS
811210, 811219
The U.S. Food and Drug Administration (FDA), through its National Forensic Chemistry Center (NFCC), is seeking multi-year maintenance service contracts for nitrogen generators at five satellite laboratory locations nationwide. - Government Buyer: - Food and Drug Administration (FDA) - Office of the Commissioner/Office of Chief Scientist/Office of Specialty Laboratories and Enforcement Support (OC/OCS/OSLES) - National Forensic Chemistry Center (NFCC) - Locations: Queens, NY; Miami, FL; Chicago, IL; Honolulu, HI; Torrance, CA - OEMs and Vendors: - Peak Scientific (referenced as provider of engineers for maintenance) - Nitrogen generator models: SLO Genius SQ 24, NG3000A, SLO HoriZen 24 - Products/Services Requested: - Preventative maintenance and repair services for nitrogen generators - SLO Genius SQ 24 (part number 723050599) - NG3000A (part number 722100187) - SLO HoriZen 24 (part numbers 724070197, 724070337, 724090345) - 1-2 onsite preventative maintenance visits per unit per year by a Peak engineer - All maintenance parts, labor, and engineer travel charges included - Compressor repair/replacement and component retrofits - Breakdown/repair service with priority onsite engineer availability - Guaranteed 48-hour onsite response time for repairs - Online technical support - Detailed field service reports after each service call and monthly maintenance activity reports - Unique/Notable Requirements: - Firm fixed price contract - Evaluation based on Lowest Price Technically Acceptable (LPTA) - Equivalent solutions may be proposed if justified and will be evaluated by the NFCC
Description
The U.S. Food and Drug Administration (FDA) / National Forensic Chemistry Center (NFCC) in the Office of the Commissioner/Office of Chief Scientist/Office of Specialty Laboratories and Enforcement Support (OC/OCS/OSLES) requires the purchase of Multi-year Service Contracts for Nitrogen Generators (all satellite lab locations). The following locations are: Queens, NY; Miami, FL; Chicago; IL; Honolulu, HI; Torrance, CA.
MINIMUM SALIENT CHARACTERISTICS
Equivalent requirements that differ from these minimum requirements shall be justified by the proposing vendor and evaluated by the NFCC prior to purchase. Minimum requirements are as follows:
General
1 or 2 (depending on model of generator) on-site Preventative Maintenance visits per year by a Peak engineer All maintenance parts, labor and engineer travel charges – Full function check – component retrofits carried out when applicable Compressor Repair/ Replacement included when required Breakdown/repair service with priority on site Engineer availability that includes all breakdown/repair parts, labor, and engineer travel charges Guaranteed on-site response time of 48 hours Online technical support
RECORDS AND REPORTS
The contractor shall, commensurate with the completion of each service call (inclusive of warranty service), provide the end-user of the equipment with a copy of a field service report/ticket identifying the equipment name, manufacturer, model number, and serial number of the equipment being serviced/repaired and detailing the reason for the service call, a detailed description of the work performed, the test instruments or other equipment used to affect the repair or otherwise perform the service, the name(s) and contact information of the technician who performed the repair/service, and for information purposes, the on-site hours expended and parts/components replaced. In addition, the Contractor shall provide monthly reports to the FDA COR and/or COR designee, no later than the fifth workday following the end of each month, summarizing all maintenance and repair activities (including warranty work) for the previous month (during months that work is performed).
Please review the enclosed RFQ FDA-75F40126Q00320 document for detailed information.