Army Solicitation for 750 kVA Pad-Mounted Transformer for Fort Buchanan, Puerto Rico
Buyer
MICC-Ft Drum
Posted
July 22, 2026
Respond By
July 29, 2026
Identifier
W911S226U3773
NAICS
335311
This procurement opportunity is issued by the Mission Installation Contracting Command (MICC) at Fort Drum for the Department of the Army: - Government Buyer: - Department of the Army, Mission Installation Contracting Command (MICC), Fort Drum - Product Requested: - One pad-mounted transformer for Fort Buchanan, Puerto Rico - Specifications: - 750 kVA, 13.2 kV/208Y/120 V, three-phase - Stainless steel construction, dead front design, pentahead security hardware - ANSI 61 grey color, welded tank, pressure tested - Electrical features: primary and secondary bushings, radial feed, ANSI standard impedance, tap changer - Protection and monitoring: fuses, gauges, indicators - Compliance Requirements: - ANSI/IEEE C57.12 series, DOE 2016 efficiency standards - NESC, NEC/NFPA 70, UFGS 26 12 19 - American Buy Act, PCB-free oil certification, UL listing - Delivery and Documentation: - Fully assembled delivery - Minimum one-year manufacturer warranty - Certified test reports, as-built drawings, installation manuals, warranty documentation - OEMs and Vendors: - No specific OEMs or vendors are named in the solicitation - Unique/Notable Requirements: - Strict compliance with multiple national and federal standards - Delivery to Puerto Rico, fully assembled, with comprehensive documentation and warranty
Description
Provide one Pad Mounted Transformer 750 kVA, 13.2 kV /208Y/120 V. Salient Characteristics: Furnish one (1) pad mounted, dead front, radial transformer, rated: ? Capacity: 750 kVA ? Phases: 3 ? Primary Voltage: 13,200 V (15 kV class) ?Secondary Voltage: 208Y/120 V ? Frequency: 60 Hz ? Phase: Three phase ? Cooling :ONAN ? Fluid: Mineral oil 2. Mandatory Physical Dimensions: The following dimensions are non negotiable: ? Height: 63?� inches (up to 64?� inches) ? Width: 65 inches ? Depth: May varies (existing is 41 inches) The Contractor shall confirm with proposal the manufacturing dimensions, either in writing or by a shop drawing, for government approval. 3. Mechanical and Construction Requirements: The transformer shall include: ?Stainless steel tank, cabinet and hardware (304) ? Dead front construction ? Pentahead security hardware ? ANSI 61 Grey color to match with existing enclosure ? Welded tank construction, sealed and pressure tested ? 1-inch Oil drain valve located on the primary side with 3/8-inch water sampler (required due to secondary side cable congestion) ? Arc-flash and safety labeling ? Lifting lugs and jacking pads ? Nameplate per ANSI C57.12.00 4.Electrical Requirements: ? Primary bushings: (6) 200 A load break wells with inserts for (3)LV and (3) 10KV arresters ? Secondary bushings: NEMA spade w/ supports terminals 10holes (3) LV and (1) neutral per ANSI ? Configuration: Radial Feed ? Impedance: Standard ANSI values for 750 kVA ? Taps: �2 x 2.5% (standard 5 position no load tap changer) 5.Protection and Monitoring: The transformer shall include: ? Bayonet fuse with isolation link? Current limiting fuses ? Load break switch (2 position minimum) ? Nitrogen pressure gauge, test port and blanket ? Temperature gauge ? Pressure vacuum gauge ? Liquid level indicator ? Schrader valve Note: All gauges must be visible. 6. Compliance Requirements: The transformer must comply with: ? ANSI/IEEE C57.12 series ? DOE 2016 efficiency standards ? National Electrical Safety Code (NESC) ? National Electrical Code (NEC /NFPA 70) ? UFGS 26 12 19 ? Pad Mounted, Liquid Filled, Medium Voltage Transformers ?American Buy Act ? PCB-free oil certification ? UL Listed 002. Provide Factory routine test Reports Results and documentation as minimum: ? Insulation resistance test ? Winding resistance test ? Turns ratio (TTR) ?Polarity and phase-relation test ? No-load and load-loss test ? Dielectric test ? Excitation test ?Impedance test ? Applied and Induced potential tests ? Leak Test ? Oil quality test (dielectric strength, moisture, interfacial tension) ? Certified As-built drawings ? Certified test report signed by manufacturer ? Installation and OM manuals ? Warranty documentation (minimum 1 year) ? Destination to the federal facility Fort Buchanan, Puerto Rico00934 ? ECD: 40 weeks ? Unit must arrive fully assembled and ready for installation ?Packing slip must include contract number, PO number, and serial number? Minimum 1 year manufacturer warranty covering defects in equipment. Additional Links:Department of Defense Procurement ToolboxPIEE Solicitation Module Link for W911S226U3773Registration Instructions for the PIEE Solicitation ModuleWeb Based Training for the PIEE Solicitation Module