Opportunity

SAM #FA480926Q0065

Structural Fire Trainer Liner Replacement for Seymour Johnson AFB

Buyer

4th Consolidated Squadron, ACC

Posted

July 15, 2026

Respond By

July 30, 2026

Identifier

FA480926Q0065

NAICS

332999, 327120, 238990

This opportunity involves the procurement of a replacement liner for a structural fire trainer at Seymour Johnson Air Force Base. - Government Buyer: - Department of Defense, Department of the Air Force, Air Combat Command, 4th Contracting Squadron (FA4809 4TH CONS SQ CC) - Location: Seymour Johnson AFB, North Carolina - Products/Services Requested: - Structural fire trainer liner engineered for live-fire training - Must be suitable for Class A, B, C, D, Electrical, and F/K fires - Liner must be made of cementitious high-temperature composite with Kevlar additives - Unique tongue and groove installation method required - Includes stainless steel mounting hardware - Thickness: 1.5 inches, no additional insulation required - Must withstand 150 psi nozzle forces - Heat transfer rate: 10.4% (1000 degree / 140 degree in 10 minutes) - Certified as a protective skin for flammable hazmat storage cells - Five to ten year warranty required - Installation must be performed by certified installers due to health impacts - Compliance Requirements: - Must comply with NFPA 1402 and all related standards - Must meet all NFPA burn matrix formulas - OEMs and Vendors: - No specific OEMs or vendors are named in the notice - Unique/Notable Requirements: - Liner must be certified for hazmat storage protection - Health and safety requirements for installation - High durability and thermal performance standards

Description

SALIENT CHARACTERISTICS for Structural Trainer Liner DESCRIPTION: Replace liner inside the structural trainer REQUIREMENTS: The liner components units shall: 1. Designed to meet all referenced safety, thermal, and regulatory specifications, this specific material is engineered for extreme live-fire training evolutions. 2. Specifically formulated for Class A, B, C, D, Electrical, and F/K fires within a controlled burn cell which complies with NFPA 1402 and related standards. 3. Made of a cementitious high temp composite formula, which has a negative health impact when installed by certified installers. 4. Have Kevlar additives 5. Unique tongue and groove installation method 6. Stainless Steel mounting hardware 7. Have five (5) to ten (10) year warranty to replace 8. Able to withstand 150 psi nozzle forces 9. 1.5 inches thick requires no additional insulation behind its barrier 10. Heat transfer 10.4% (1000 degree / 140 degree in 10 minutes) 11. Complies with all NFPA suggested burn matrix formulas 12. Certified as a protective skin for flammable hazmat storage cells

View original listing