Opportunity
New York State Contract Reporter #2137128
NYS SDVOB Subcontractor Opportunity: Electrical Switchgear & Testing at Green Haven Correctional Facility
Posted
July 15, 2026
Respond By
August 19, 2026
Identifier
2137128
NAICS
238210
This opportunity seeks New York State-certified Service-Disabled Veteran-Owned Business (SDVOB) subcontractors for electrical switchgear and partial discharge testing at Green Haven Correctional Facility in Stormville, NY. - Government Buyer: - New York State, Green Haven Correctional Facility (Prime: LND Technical Services, LLC) - OEMs Highlighted: - Eaton (15kV vacuum circuit breakers) - Schweitzer Engineering Laboratories (SEL) (SEL-751A, SEL-700G, SEL-587Z protective relays) - MTU (13.2kV, 2MW generators) - Deka (Unigy battery systems) - Fluke (Fluke-100-CLKT infrared windows) - Products/Services Requested: - Testing and maintenance of 14 Eaton 15kV vacuum circuit breakers - Testing and maintenance of 12 SEL-751A protective relays, SEL-700G and SEL-587Z relays - Testing and maintenance of transfer switches, transformers, battery banks (10 Deka Unigy units), chargers, and analog metering systems - Visual inspections of electrical distribution systems - Provision and operation of 2 MTU 13.2kV, 2MW portable generators for outage support - Installation of Fluke 4” Round, model Fluke-100-CLKT UL-listed infrared windows in switchgear cabinets - Arc Flash Safety Awareness and Portable Generator Connection Training (OSHA and NFPA 70E compliant) - Unique/Notable Requirements: - All work must be performed by a NYS Registered Professional Electrical Engineer - Compliance with InterNational Electrical Testing Association standards, OSHA, NFPA 70E, and NYS prevailing wage - MBE and SDVOB participation goals (15% and 6%, respectively) - Emphasis on safety training and temporary power continuity during outages
Description
This opportunity is for certified Service-Disabled Veteran-Owned Business (SDVOB) firms in New York State to partner as subcontractors for electrical switchgear testing and partial discharge testing at Green Haven Correctional Facility. The scope includes testing and maintenance of 15kV vacuum circuit breakers, protective relays, transfer switches, transformers, battery banks, and visual inspections of electrical distribution systems. The work also involves providing portable generators during outages, installing infrared windows in switchgear cabinets, and delivering safety training in accordance with OSHA and NFPA 70E standards. All work must be performed by a New York State Registered Professional Electrical Engineer and comply with prevailing wage requirements.