Opportunity

SAM #VEID260013

Solicitation for Illumina sequencing reagents for MiSeq and MiniSeq platforms at NAMRU SOUTH

Buyer

Naval Medical Research Center

Posted

July 14, 2026

Respond By

July 29, 2026

Identifier

VEID260013

NAICS

424210

NAMRU SOUTH is seeking Illumina sequencing reagents for use with MiSeq and MiniSeq platforms. - Agency: U.S. Naval Medical Research Unit SOUTH (NAMRU SOUTH), Department of Defense - Products requested: - Illumina PhiX control v3 kit (FC-110-3001) - Illumina MiSeq Reagent Kit v3 (600-cycle) (MS-102-3003) - Illumina Nextera XT DNA Sample Preparation Kit (FC-131-1096) - Illumina Nextera XT Index Kit v2 Set A (FC-131-2001) - Illumina MiniSeq High Output Reagent Kit (300-cycles) (FC-420-1003) - Illumina Nextera XT Index Kit v2 Set B (FC-131-2002) - Requirements: - Kits must support low DNA input (~50ng), dual indexing, and paired-end sequencing - Sequencing kits must support >150 cycles and high Q30 values - Internal controls and master-mixed reagents required - Cold chain shipping to Callao, Peru - Vendors must notify users of expiration dates before shipment and obtain approval - Illumina is the specified OEM for all products - No hazardous materials; all items must be delivered upon award signature

Description

PERFORMANCE WORK STATEMENT

SCOPE

The laboratory of the Virology Department of the U.S. Naval Medical Research Unit SOUTH (NAMRU SOUTH) is looking to purchase reagents to prepare libraries using human samples that later will be sequenced in the MiSeq and MiniSeq platforms developed by Illumina, as part of the projects of next-generation sequencing (NGS) that are being conducted at this command.

BACKGROUND

The kits must be designed for library preparation and sequencing. The library preparation kit should include a variety of steps that include enzymatic fragmentation, size selection, end-repair, a-tail and ligation step in the same reaction. The process should allow including dual index at the 5 and 3 prime ends for later sample identification. Also, the library preparation kit should be designed to construct libraries with a low DNA input (~50ng) with master-mixed reagents ready to use. Similarly, the sequencing kit should allow us to run more than 150 sequencing cycles. Those cycles are needed to run paired-end libraries with a high-quality performance. We expect to have more than 2.0Gb per sequencing run with high Q30 values. Finally, the sequencing kit should include an internal control to validate the sequencing run.

REQUIREMENTS

<ol>
    <li>Location of work / Place of delivery</li>
</ol>
</li>

Shipment to NAMRU SOUTH – Callao, Peru

Period of performance / Delivery time

In accordance with deliverables schedule.

Deliverables schedule (if applicable)

Materials should be shipped upon award signature.

Hazardous material category. 

None of the items are hazardous materials.

List of products

FC-110-3001  PhiX control v3 kit

MS-102-3003  MiSeq Reagent Kit v3 (600-cycle)

FC-131-1096  Nextera XT DNA Sample Preparation Kit

FC-131-2001 Nextera XT Index Kit v2 Set A (96 indexes, 384 samples)

FC-420-1003  MiniSeq High Output Reagent Kit (300-cycles)

FC-131-2002  Nextera XT Index Kit v2 Set B (96 indexes, 384 samples)

Applicable Standards

These reagents are very time-sensitive and have limited expiration dates, reason for which, vendor should inform final users of expiration dates as soon as they become available and request their approval prior to shipment.

Special Requirements

All materials require cold chain.

View original listing