Opportunity

C.E. Gleeson Constructors Inc. Procureware #91c09826-e264-49fe-9809-d0aa8133ce43

Tenant Improvement Construction Services for 23,970 SF Commercial Space in Daytona Beach, FL

Posted

July 13, 2026

Respond By

August 06, 2026

Identifier

91c09826-e264-49fe-9809-d0aa8133ce43

NAICS

236220, 238190

This opportunity involves a tenant improvement project for a 23,970 square foot commercial space in Daytona Beach, Florida, managed by Gleeson Constructors. - Government Buyer: - Gleeson Constructors (acting as construction manager/general contractor) - Scope of Work: - General requirements: construction waste management, temporary facilities/utilities - Site work: selective demolition, concrete cutting/coring, MEP demolition - Concrete: sidewalks, frost slabs, patching - Masonry: exterior brick - Metals: structural steel, roof deck infill, RTU support steel, bollards - Wood and plastics: exterior sheathing, insulation, cement board, cabinets, countertops, shelving - Thermal and moisture protection: waterproofing, insulation, membrane roofing, roof hatch, gutters - EIFS patching - Doors and windows: hollow metal doors/frames, hardware, automatic sliding doors - Glass and glazing: aluminum frames, storefront glass - Finishes: metal framing, gypsum board, polished/sealed concrete, epoxy flooring, tile, painting, wallpaper, wall protection - Specialties: corner guards, architectural panels, canopies, toilet accessories, appliances, corkboards, whiteboards, lockers, dock equipment - Furnishings: fixture package by others - Fire protection: sprinkler systems - Plumbing: water/gas piping, heaters, pumps, valves, fixtures - HVAC: exhaust fans, ceiling fans, grilles, diffusers, air balancing, building automation - Electrical: fire alarm system, smoke detectors, lighting, gear, switches, outlets, feeders, low voltage rough-in - Unique/Notable Requirements: - Open shop (non-union) - Non-prevailing wage - No specific OEMs or vendors are named in the solicitation - No product part numbers or quantities for specific equipment are provided in the solicitation.

Description

This solicitation is for tenant improvement of an existing 1 story 23,970 SF commercial space. The scope of work includes various construction divisions such as general requirements, site work, concrete, masonry, metals, wood and plastics, thermal and moisture protection, EIFS, doors and windows, glass and glazing, finishes, specialties, furnishings, fire protection, plumbing, HVAC, and electrical. The project is open shop and non-prevailing wage. Bids must be emailed to estimating@gleesonconstructors.com, and RFIs are due by August 5, 2026.

View original listing