HVAC System Replacement at Mashpee Service Unit (Trane/Bard Units)

Buyer

Nashville Area Indian Health Service

Posted

July 13, 2026

Respond By

August 12, 2026

Identifier

75H71526R00006

NAICS

238220

This opportunity is for the replacement of HVAC systems at the Mashpee Service Unit, managed by the Indian Health Service under the Department of Health and Human Services. - Government Buyer: - Agency: Department of Health and Human Services - Sub-agency: Indian Health Service - Office: Mashpee Service Unit - OEMs Highlighted: - Trane (referenced as the model standard for new rooftop units) - Bard (referenced as existing units being replaced) - Products/Services Requested: - Furnish and install seven new packaged rooftop HVAC units - Admin and Medical buildings: 4-ton nominal cooling capacity, commercial-grade packaged gas/electric rooftop units equivalent to Trane model 4DCY4048B1096AA or modern successor - Dental building: units sized to match existing capacities and compatible with current utilities and structural loads - Includes curb adapters, airflow and humidity control per ACCA/ASHRAE standards, factory-authorized startup, commissioning, and disposal of old units - Full-service scope: mobilization, removal of existing Trane and Bard units, installation, commissioning, and compliance with safety, building codes, and environmental regulations - Unique/Notable Requirements: - Emphasis on quality, reliability, and compliance with performance standards - Work must minimize impact on occupied healthcare facilities - Contractor must provide all labor, supervision, tools, materials, and equipment - Performance and payment bonds required - Project completion required within 180 days from notice to proceed

Description

Replace Roof Top Units on Admin Building: Remove the two existing Trane package rooftop units from the 2,400 SF Admin Building. Install a new rooftop unit appropriately sized for the building’s cooling and heating needs. Replace Roof Top Units on Medical Building Remove the two existing Trane package rooftop units from the 2,400 SF Medical Building. Install a new rooftop unit appropriately sized for the building’s cooling and heating needs. Replace Package Vertical Mounted Unit on Admin Building: Remove the existing Bard package unit from the 2,400 SF Dental Building. Install a new vertical mounted packaged unit appropriately sized for the building’s cooling and heating needs. Replace Package Vertical Mounted Units on Dental Building: Remove the two existing Bard package units from the 2,400 SF Dental Building. Install a new vertical mounted packaged unit appropriately sized for the building’s cooling and heating needs.

View original listing