Dobbins ARB Building 510 HVAC and DDC Controls Repair and Reconfiguration

Buyer

94th Contracting Flight

Posted

July 13, 2026

Respond By

August 13, 2026

Identifier

FA670326Q0002

NAICS

238220

This opportunity seeks a contractor to repair and reconfigure the HVAC and DDC Controls in Building 510 at Dobbins Air Reserve Base, Georgia. - Government Buyer: - Department of the Air Force, Air Force Reserve Command, 94th Contracting Flight (FA6703), 94th Airlift Wing, 94th Logistics Group, and 94th Civil Engineer Squadron at Dobbins Air Reserve Base - OEMs and Vendors Mentioned: - Aprilaire (model 1850 dehumidifier) - Monaco (fire alarm system model 227-855 compatible smoke detectors) - Schneider Electric (PM5560, PM8000, ION 8650 electric meters) - Siemens (9410 electric meter) - Products/Services Requested: - Removal and replacement of 5-ton heat pump and furnace (1 each) - Relocation of 3.5-ton furnace and installation of new ductwork (1 each) - Installation of inline high-capacity whole-home dehumidifier (Aprilaire model 1850, 1 each) - Installation of new smoke detectors compatible with Monaco fire alarm system (2 each) - Replacement of storage room and exterior doors, double pane windows (2 each), and ceilings with mold-resistant drywall - Installation of MERV-13 disposable pleated filters, copper refrigerant piping, flexible neoprene-glass fabric connections, foil-faced fiberglass duct wrap insulation, and foamed pipe insulation - Installation of AMRS-compliant electric meters (e.g., Schneider Electric, Siemens models) with Modbus/TCP and UMCS integration - Duct air leakage test (DALT), test and balance (T&B), performance and verification test (PVT), and HVAC duct cleaning/remediation - Relocation and installation of fan coil units, controls, and vibration isolation hangers - Mold remediation, painting, and moving/storing building contents - Unique or Notable Requirements: - All work must comply with Air Force, federal, state, and local codes, including DAFMAN, DAFI, UFC-430-01FA, Dobbins Design Guide, and United Facilities Criteria - Compliance with historic preservation standards and NADCA standards for duct cleaning - Integration of HVAC controls and electric meters with the base Utility Management and Control System (UMCS) - Salvaging and government turnover of removed items - Minimum insulation values (R49), MERV-13 filtration, and specific product compatibility (e.g., Monaco fire alarm system) - 12-month warranty period for installed systems

Description

At Building 510, the Contractor will reconfigure the HVAC and DDC Controls throughout and replace mold damaged drywall. Contractor is responsible for moving and storing all contents of the building. All work performed must meet local, state, and federal codes including but not limited to all applicable Department of Air Force Requirements (DAFMAN and DAFI), UFC-430-01FA, Dobbins Design Guide and Dobbins' specifications 101, 1560, 1330 and  the United Facilities Criteria's (UFC).

View original listing