Opportunity
Virginia Danville Civic Plus #RFQ Q004174
Danville Utilities Solicits Quotes for Cathodic Protection System Materials (Phase 1, Bromley Rd.)
Posted
July 10, 2026
Respond By
July 22, 2026
Identifier
RFQ Q004174
NAICS
237130, 237990
The City of Danville Utilities Department is seeking quotations for Phase 1 of the Bromley Rd. Crossing Linear Anode/Rectifier Installation project. - Government Buyer: - City of Danville Utilities Department, Purchasing Office - OEMs Highlighted: - MATCOR (SPL-FBR linear anode) - Universal Rectifiers (Wilson Street Rectifier, custom junction box) - Mobiltex (RMU3-G remote monitoring unit) - Cott Big Fink (anode test stations) - Burndy (crimpit connectors) - Products and Quantities: - 1,025 feet of MATCOR SPL-FBR impressed current linear anode cable (#2 AWG HMWPE) - 1 Universal Rectifiers Wilson Street Rectifier (Model ASAI-60-15-A-CFRRW, prewired for remote monitoring) - Various cables: #2 AWG HMWPE (red), #4 AWG HMWPE (black), #6 AWG XHHW (green); price per foot, total length TBD - 1 two-part epoxy pipe coating kit (SP-2888, 2-liter) - 10 pieces of 1-1/2 inch Schedule 80 rigid PVC conduit - 3 rolls of 3-inch cable marking tape ('Cathodic Protection Cable Buried Below') - 1 Scotch cast wye resin splice kit (model 90-B1 or equivalent) - 1 box Burndy crimpit (YC2C2 or equivalent) - 1 copper clad ground rod (3/4 inch x 10 ft) - 1 Mobiltex RMU3-G remote monitoring unit (with service/set-up) - 1 pressure treated wood post (6 x 6 x 16 ft or equivalent) - 100 feet of non-metallic split duct or 3 inch PVC conduit - 4 Cott Big Fink anode test stations (stainless hardware, 5 terminals, 0.001 ohm 25 amp shunt) - 1 Universal Rectifiers custom junction box (NEMA 3R, galvanized steel, Danville Utilities approved) - Notable Requirements: - Some items require Danville Utilities approval (rectifier, junction box) - Remote monitoring capability is required (Mobiltex RMU3-G) - Price per foot requested for cables with unknown total quantities - Project is Phase 1 of a two-phase cathodic protection installation
Description
This solicitation is a Request for Quotation (RFQ) for Phase 1 of the Bromley Rd. Crossing Linear Anode/Rectifier Installation. The project involves the procurement and installation of materials such as linear anodes, rectifiers, cables, epoxy pipe coating, conduits, splice kits, ground rods, remote monitoring units, and junction boxes. The RFQ specifies quantities and descriptions for each item required for the installation. The bid is open for submission until July 22, 2026, with questions accepted until July 15, 2026.